瀏覽代碼

[SCSI] mpt2sas: Excessive log info causes sas iounit page time out

Inhibit 0x3117 loginfos - during cable pull, there are too many printks going
to the syslog, this is have impact on how fast the interrupt routine can handle
keeping up with command completions; this was the root cause to the config
pages timeouts.

Signed-off-by: Kashyap Desai <kashyap.desai@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Kashyap, Desai 15 年之前
父節點
當前提交
be9e8cd75c
共有 2 個文件被更改,包括 8 次插入0 次删除
  1. 4 0
      drivers/scsi/mpt2sas/mpt2sas_base.c
  2. 4 0
      drivers/scsi/mpt2sas/mpt2sas_scsih.c

+ 4 - 0
drivers/scsi/mpt2sas/mpt2sas_base.c

@@ -440,6 +440,10 @@ _base_sas_log_info(struct MPT2SAS_ADAPTER *ioc , u32 log_info)
 	if (sas_loginfo.dw.bus_type != 3 /*SAS*/)
 		return;
 
+	/* each nexus loss loginfo */
+	if (log_info == 0x31170000)
+		return;
+
 	/* eat the loginfos associated with task aborts */
 	if (ioc->ignore_loginfos && (log_info == 30050000 || log_info ==
 	    0x31140000 || log_info == 0x31130000))

+ 4 - 0
drivers/scsi/mpt2sas/mpt2sas_scsih.c

@@ -2767,6 +2767,10 @@ _scsih_scsi_ioc_info(struct MPT2SAS_ADAPTER *ioc, struct scsi_cmnd *scmd,
 	char *desc_ioc_state = NULL;
 	char *desc_scsi_status = NULL;
 	char *desc_scsi_state = ioc->tmp_string;
+	u32 log_info = le32_to_cpu(mpi_reply->IOCLogInfo);
+
+	if (log_info == 0x31170000)
+		return;
 
 	switch (ioc_status) {
 	case MPI2_IOCSTATUS_SUCCESS: