@@ -55,6 +55,7 @@ MODULE_PARM_DESC(reset, "Set to 1 to reset chip, not recommended");
|
|
|
#define W83795_REG_I2C_ADDR 0xfc
|
|
|
#define W83795_REG_CONFIG 0x01
|
|
|
#define W83795_REG_CONFIG_CONFIG48 0x04
|
|
|
+#define W83795_REG_CONFIG_START 0x01
|
|
|
|
|
|
/* Multi-Function Pin Ctrl Registers */
|
|
|
#define W83795_REG_VOLT_CTRL1 0x02
|
|
@@ -1664,12 +1665,18 @@ static const struct sensor_device_attribute_2 sda_single_files[] = {
|
|
|
|
|
|
static void w83795_init_client(struct i2c_client *client)
|
|
|
{
|
|
|
+ u8 config;
|
|
|
+
|
|
|
if (reset)
|
|
|
w83795_write(client, W83795_REG_CONFIG, 0x80);
|
|
|
|
|
|
- /* Start monitoring */
|
|
|
- w83795_write(client, W83795_REG_CONFIG,
|
|
|
- w83795_read(client, W83795_REG_CONFIG) | 0x01);
|
|
|
+ /* Start monitoring if needed */
|
|
|
+ config = w83795_read(client, W83795_REG_CONFIG);
|
|
|
+ if (!(config & W83795_REG_CONFIG_START)) {
|
|
|
+ dev_info(&client->dev, "Enabling monitoring operations\n");
|
|
|
+ w83795_write(client, W83795_REG_CONFIG,
|
|
|
+ config | W83795_REG_CONFIG_START);
|
|
|
+ }
|
|
|
}
|
|
|
|
|
|
static int w83795_get_device_id(struct i2c_client *client)
|