Browse Source

spi/s3c64xx: Add missing pm_runtime_put on setup fail

pm_runtime_put() wasn't called if clock rate could not be set up in
s3c64xx_spi_setup() leading to invalid count of device pm_runtime usage.

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
Krzysztof Kozlowski 11 years ago
parent
commit
7b8f7eef1a
1 changed files with 1 additions and 0 deletions
  1. 1 0
      drivers/spi/spi-s3c64xx.c

+ 1 - 0
drivers/spi/spi-s3c64xx.c

@@ -1121,6 +1121,7 @@ static int s3c64xx_spi_setup(struct spi_device *spi)
 	return 0;
 
 setup_exit:
+	pm_runtime_put(&sdd->pdev->dev);
 	/* setup() returns with device de-selected */
 	disable_cs(sdd, spi);