Browse Source

spi/s3c64xx: Add missing pm_runtime_set_active() call in probe()

Mark device as PM runtime active during initialization to reflect
actual device power/clocks state. This reduces the enable count for SPI
bus controller gate clock so it can be disabled when the bus controller
is not used.

Signed-off-by: Krzysztof Kozlowski <k.kozlowski@samsung.com>
Signed-off-by: Kyungmin Park <kyungmin.park@samsung.com>
Reviewed-by: Sylwester Nawrocki <s.nawrocki@samsung.com>
Signed-off-by: Mark Brown <broonie@linaro.org>
Krzysztof Kozlowski 12 years ago
parent
commit
3833825011
1 changed files with 1 additions and 0 deletions
  1. 1 0
      drivers/spi/spi-s3c64xx.c

+ 1 - 0
drivers/spi/spi-s3c64xx.c

@@ -1428,6 +1428,7 @@ static int s3c64xx_spi_probe(struct platform_device *pdev)
 	       S3C64XX_SPI_INT_TX_OVERRUN_EN | S3C64XX_SPI_INT_TX_UNDERRUN_EN,
 	       sdd->regs + S3C64XX_SPI_INT_EN);
 
+	pm_runtime_set_active(&pdev->dev);
 	pm_runtime_enable(&pdev->dev);
 
 	if (spi_register_master(master)) {