@@ -63,7 +63,11 @@ enum regulator_status {
|
|
|
* when running with the specified parameters.
|
|
|
*
|
|
|
* @enable_time: Time taken for the regulator voltage output voltage to
|
|
|
- * stabalise after being enabled, in microseconds.
|
|
|
+ * stabilise after being enabled, in microseconds.
|
|
|
+ * @set_voltage_time_sel: Time taken for the regulator voltage output voltage
|
|
|
+ * to stabilise after being set to a new value, in microseconds.
|
|
|
+ * The function provides the from and to voltage selector, the
|
|
|
+ * function should return the worst case.
|
|
|
*
|
|
|
* @set_suspend_voltage: Set the voltage for the regulator when the system
|
|
|
* is suspended.
|
|
@@ -103,8 +107,11 @@ struct regulator_ops {
|
|
|
int (*set_mode) (struct regulator_dev *, unsigned int mode);
|
|
|
unsigned int (*get_mode) (struct regulator_dev *);
|
|
|
|
|
|
- /* Time taken to enable the regulator */
|
|
|
+ /* Time taken to enable or set voltage on the regulator */
|
|
|
int (*enable_time) (struct regulator_dev *);
|
|
|
+ int (*set_voltage_time_sel) (struct regulator_dev *,
|
|
|
+ unsigned int old_selector,
|
|
|
+ unsigned int new_selector);
|
|
|
|
|
|
/* report regulator status ... most other accessors report
|
|
|
* control inputs, this reports results of combining inputs
|