@@ -112,6 +112,29 @@ temperature) and throttle appropriate devices.
|
|
|
trip: indicates which trip point the cooling devices is associated with
|
|
|
in this thermal zone.
|
|
|
|
|
|
+1.4 Thermal Zone Parameters
|
|
|
+1.4.1 struct thermal_bind_params
|
|
|
+ This structure defines the following parameters that are used to bind
|
|
|
+ a zone with a cooling device for a particular trip point.
|
|
|
+ .cdev: The cooling device pointer
|
|
|
+ .weight: The 'influence' of a particular cooling device on this zone.
|
|
|
+ This is on a percentage scale. The sum of all these weights
|
|
|
+ (for a particular zone) cannot exceed 100.
|
|
|
+ .trip_mask:This is a bit mask that gives the binding relation between
|
|
|
+ this thermal zone and cdev, for a particular trip point.
|
|
|
+ If nth bit is set, then the cdev and thermal zone are bound
|
|
|
+ for trip point n.
|
|
|
+ .match: This call back returns success(0) if the 'tz and cdev' need to
|
|
|
+ be bound, as per platform data.
|
|
|
+1.4.2 struct thermal_zone_params
|
|
|
+ This structure defines the platform level parameters for a thermal zone.
|
|
|
+ This data, for each thermal zone should come from the platform layer.
|
|
|
+ This is an optional feature where some platforms can choose not to
|
|
|
+ provide this data.
|
|
|
+ .governor_name: Name of the thermal governor used for this zone
|
|
|
+ .num_tbps: Number of thermal_bind_params entries for this zone
|
|
|
+ .tbp: thermal_bind_params entries
|
|
|
+
|
|
|
2. sysfs attributes structure
|
|
|
|
|
|
RO read only value
|
|
@@ -126,6 +149,7 @@ Thermal zone device sys I/F, created once it's registered:
|
|
|
|---type: Type of the thermal zone
|
|
|
|---temp: Current temperature
|
|
|
|---mode: Working mode of the thermal zone
|
|
|
+ |---policy: Thermal governor used for this zone
|
|
|
|---trip_point_[0-*]_temp: Trip point temperature
|
|
|
|---trip_point_[0-*]_type: Trip point type
|
|
|
|---trip_point_[0-*]_hyst: Hysteresis value for this trip point
|
|
@@ -187,6 +211,10 @@ mode
|
|
|
charge of the thermal management.
|
|
|
RW, Optional
|
|
|
|
|
|
+policy
|
|
|
+ One of the various thermal governors used for a particular zone.
|
|
|
+ RW, Required
|
|
|
+
|
|
|
trip_point_[0-*]_temp
|
|
|
The temperature above which trip point will be fired.
|
|
|
Unit: millidegree Celsius
|
|
@@ -264,6 +292,7 @@ method, the sys I/F structure will be built like this:
|
|
|
|---type: acpitz
|
|
|
|---temp: 37000
|
|
|
|---mode: enabled
|
|
|
+ |---policy: step_wise
|
|
|
|---trip_point_0_temp: 100000
|
|
|
|---trip_point_0_type: critical
|
|
|
|---trip_point_1_temp: 80000
|
|
@@ -305,3 +334,38 @@ to a thermal_zone_device when it registers itself with the framework. The
|
|
|
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
|
|
|
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
|
|
|
crosses any of the configured thresholds.
|
|
|
+
|
|
|
+5. Export Symbol APIs:
|
|
|
+
|
|
|
+5.1: get_tz_trend:
|
|
|
+This function returns the trend of a thermal zone, i.e the rate of change
|
|
|
+of temperature of the thermal zone. Ideally, the thermal sensor drivers
|
|
|
+are supposed to implement the callback. If they don't, the thermal
|
|
|
+framework calculated the trend by comparing the previous and the current
|
|
|
+temperature values.
|
|
|
+
|
|
|
+5.2:get_thermal_instance:
|
|
|
+This function returns the thermal_instance corresponding to a given
|
|
|
+{thermal_zone, cooling_device, trip_point} combination. Returns NULL
|
|
|
+if such an instance does not exist.
|
|
|
+
|
|
|
+5.3:notify_thermal_framework:
|
|
|
+This function handles the trip events from sensor drivers. It starts
|
|
|
+throttling the cooling devices according to the policy configured.
|
|
|
+For CRITICAL and HOT trip points, this notifies the respective drivers,
|
|
|
+and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
|
|
|
+The throttling policy is based on the configured platform data; if no
|
|
|
+platform data is provided, this uses the step_wise throttling policy.
|
|
|
+
|
|
|
+5.4:thermal_cdev_update:
|
|
|
+This function serves as an arbitrator to set the state of a cooling
|
|
|
+device. It sets the cooling device to the deepest cooling state if
|
|
|
+possible.
|
|
|
+
|
|
|
+5.5:thermal_register_governor:
|
|
|
+This function lets the various thermal governors to register themselves
|
|
|
+with the Thermal framework. At run time, depending on a zone's platform
|
|
|
+data, a particular governor is used for throttling.
|
|
|
+
|
|
|
+5.6:thermal_unregister_governor:
|
|
|
+This function unregisters a governor from the thermal framework.
|