@@ -1368,6 +1368,24 @@ void thermal_cdev_update(struct thermal_cooling_device *cdev)
|
|
|
}
|
|
|
EXPORT_SYMBOL(thermal_cdev_update);
|
|
|
|
|
|
+/**
|
|
|
+ * notify_thermal_framework - Sensor drivers use this API to notify framework
|
|
|
+ * @tz: thermal zone device
|
|
|
+ * @trip: indicates which trip point has been crossed
|
|
|
+ *
|
|
|
+ * This function handles the trip events from sensor drivers. It starts
|
|
|
+ * throttling the cooling devices according to the policy configured.
|
|
|
+ * For CRITICAL and HOT trip points, this notifies the respective drivers,
|
|
|
+ * and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
|
|
|
+ * The throttling policy is based on the configured platform data; if no
|
|
|
+ * platform data is provided, this uses the step_wise throttling policy.
|
|
|
+ */
|
|
|
+void notify_thermal_framework(struct thermal_zone_device *tz, int trip)
|
|
|
+{
|
|
|
+ handle_thermal_trip(tz, trip);
|
|
|
+}
|
|
|
+EXPORT_SYMBOL(notify_thermal_framework);
|
|
|
+
|
|
|
/**
|
|
|
* create_trip_attrs - create attributes for trip points
|
|
|
* @tz: the thermal zone device
|