瀏覽代碼

Fix data stage name matching issue

This fix allows the name of the stage to be specifed after the
controler and DIMM is specified.  Prior to this fix, if the
data stage name is not the first entry on the command line,
the operation is applied to all controller and DIMMs.

Signed-off-by: James Yang <James.Yang@freescale.com>
Signed-off-by: Andy Fleming <afleming@freescale.com>
James Yang 12 年之前
父節點
當前提交
992f2fb28c
共有 1 個文件被更改,包括 2 次插入1 次删除
  1. 2 1
      arch/powerpc/cpu/mpc8xxx/ddr/interactive.c

+ 2 - 1
arch/powerpc/cpu/mpc8xxx/ddr/interactive.c

@@ -1390,9 +1390,10 @@ static unsigned int fsl_ddr_parse_interactive_cmd(
 
 	unsigned int i, j;
 	unsigned int error = 0;
-	unsigned int matched = 0;
 
 	for (i = 1; i < argc; i++) {
+		unsigned int matched = 0;
+
 		for (j = 0; j < n_opts; j++) {
 			if (strcmp(options[j].data_name, argv[i]) != 0)
 				continue;