@@ -8,7 +8,9 @@ Required properties:
|
|
|
- samsung,max-temp : Maximum temperature value (125 degree celsius)
|
|
|
- Current temperature of SoC should be less than this value.
|
|
|
- samsung,start-warning : Temperature at which TMU starts giving warning (degree celsius)
|
|
|
- - samsung,start-tripping : Temperature at which system will trip and shutdown (degree celsius)
|
|
|
+ - samsung,start-tripping : Temperature at which TMU shuts down the system (degree celsius)
|
|
|
+ - samsung,hw-tripping : Temperature at which hardware tripping should happen
|
|
|
+ in case TMU fails to power off (degree celsius)
|
|
|
- samsung,efuse-min-value : SOC efuse min value (Constant 40)
|
|
|
- efuse-value should be more than this value.
|
|
|
- samsung,efuse-value : SOC actual efuse value (Literal value)
|
|
@@ -33,6 +35,7 @@ tmu@10060000 {
|
|
|
samsung,max-temp = <125>;
|
|
|
samsung,start-warning = <95>;
|
|
|
samsung,start-tripping = <105>;
|
|
|
+ samsung,hw-tripping = <110>;
|
|
|
samsung,efuse-min-value = <40>;
|
|
|
samsung,efuse-value = <55>;
|
|
|
samsung,efuse-max-value = <100>;
|