瀏覽代碼

Fix sc520 timer interrupt generation

The current implementation has the timer being started before the interrupt
handler is installed. It the interrupt occurs before the handler is
installed, the timer interrupt is never reset and the timer stops

Signed-off-by: Graeme Russ <graeme.russ@gmail.com>
Graeme Russ 15 年之前
父節點
當前提交
04ff9ab158
共有 1 個文件被更改,包括 3 次插入3 次删除
  1. 3 3
      cpu/i386/sc520/sc520_timer.c

+ 3 - 3
cpu/i386/sc520/sc520_timer.c

@@ -54,9 +54,6 @@ int timer_init(void)
 	write_mmcr_word (SC520_GPTMR1MAXCMPA, 100);
 	write_mmcr_word (SC520_GPTMR1CTL, 0xe009);
 
-	/* Clear the GP Timers status register */
-	write_mmcr_byte (SC520_GPTMRSTA, 0x07);
-
 	/* Register the SC520 specific timer interrupt handler */
 	register_timer_isr (sc520_timer_isr);
 
@@ -64,6 +61,9 @@ int timer_init(void)
 	irq_install_handler (0, timer_isr, NULL);
 	unmask_irq (0);
 
+	/* Clear the GP Timer 1 status register to get the show rolling*/
+	write_mmcr_byte (SC520_GPTMRSTA, 0x02);
+
 	return 0;
 }