mtd-physmap.txt 2.7 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384
  1. CFI or JEDEC memory-mapped NOR flash, MTD-RAM (NVRAM...)
  2. Flash chips (Memory Technology Devices) are often used for solid state
  3. file systems on embedded devices.
  4. - compatible : should contain the specific model of mtd chip(s)
  5. used, if known, followed by either "cfi-flash", "jedec-flash"
  6. or "mtd-ram".
  7. - reg : Address range(s) of the mtd chip(s)
  8. It's possible to (optionally) define multiple "reg" tuples so that
  9. non-identical chips can be described in one node.
  10. - bank-width : Width (in bytes) of the bank. Equal to the
  11. device width times the number of interleaved chips.
  12. - device-width : (optional) Width of a single mtd chip. If
  13. omitted, assumed to be equal to 'bank-width'.
  14. - #address-cells, #size-cells : Must be present if the device has
  15. sub-nodes representing partitions (see below). In this case
  16. both #address-cells and #size-cells must be equal to 1.
  17. - no-unaligned-direct-access: boolean to disable the default direct
  18. mapping of the flash.
  19. On some platforms (e.g. MPC5200) a direct 1:1 mapping may cause
  20. problems with JFFS2 usage, as the local bus (LPB) doesn't support
  21. unaligned accesses as implemented in the JFFS2 code via memcpy().
  22. By defining "no-unaligned-direct-access", the flash will not be
  23. exposed directly to the MTD users (e.g. JFFS2) any more.
  24. - linux,mtd-name: allow to specify the mtd name for retro capability with
  25. physmap-flash drivers as boot loader pass the mtd partition via the old
  26. device name physmap-flash.
  27. - use-advanced-sector-protection: boolean to enable support for the
  28. advanced sector protection (Spansion: PPB - Persistent Protection
  29. Bits) locking.
  30. For JEDEC compatible devices, the following additional properties
  31. are defined:
  32. - vendor-id : Contains the flash chip's vendor id (1 byte).
  33. - device-id : Contains the flash chip's device id (1 byte).
  34. The device tree may optionally contain sub-nodes describing partitions of the
  35. address space. See partition.txt for more detail.
  36. Example:
  37. flash@ff000000 {
  38. compatible = "amd,am29lv128ml", "cfi-flash";
  39. reg = <ff000000 01000000>;
  40. bank-width = <4>;
  41. device-width = <1>;
  42. #address-cells = <1>;
  43. #size-cells = <1>;
  44. fs@0 {
  45. label = "fs";
  46. reg = <0 f80000>;
  47. };
  48. firmware@f80000 {
  49. label ="firmware";
  50. reg = <f80000 80000>;
  51. read-only;
  52. };
  53. };
  54. Here an example with multiple "reg" tuples:
  55. flash@f0000000,0 {
  56. #address-cells = <1>;
  57. #size-cells = <1>;
  58. compatible = "intel,PC48F4400P0VB", "cfi-flash";
  59. reg = <0 0x00000000 0x02000000
  60. 0 0x02000000 0x02000000>;
  61. bank-width = <2>;
  62. partition@0 {
  63. label = "test-part1";
  64. reg = <0 0x04000000>;
  65. };
  66. };
  67. An example using SRAM:
  68. sram@2,0 {
  69. compatible = "samsung,k6f1616u6a", "mtd-ram";
  70. reg = <2 0 0x00200000>;
  71. bank-width = <2>;
  72. };