Kconfig 69 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802180318041805180618071808180918101811181218131814181518161817181818191820182118221823182418251826182718281829183018311832183318341835183618371838183918401841184218431844184518461847184818491850185118521853185418551856185718581859186018611862186318641865186618671868186918701871187218731874187518761877187818791880188118821883188418851886188718881889189018911892189318941895189618971898189919001901190219031904190519061907190819091910191119121913
  1. menu "SCSI device support"
  2. config SCSI_MOD
  3. tristate
  4. default y if SCSI=n || SCSI=y
  5. default m if SCSI=m
  6. config RAID_ATTRS
  7. tristate "RAID Transport Class"
  8. default n
  9. depends on BLOCK
  10. depends on SCSI_MOD
  11. ---help---
  12. Provides RAID
  13. config SCSI
  14. tristate "SCSI device support"
  15. depends on BLOCK
  16. select SCSI_DMA if HAS_DMA
  17. ---help---
  18. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  19. any other SCSI device under Linux, say Y and make sure that you know
  20. the name of your SCSI host adapter (the card inside your computer
  21. that "speaks" the SCSI protocol, also called SCSI controller),
  22. because you will be asked for it.
  23. You also need to say Y here if you have a device which speaks
  24. the SCSI protocol. Examples of this include the parallel port
  25. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  26. Channel, and FireWire storage.
  27. To compile this driver as a module, choose M here and read
  28. <file:Documentation/scsi/scsi.txt>.
  29. The module will be called scsi_mod.
  30. However, do not compile this as a module if your root file system
  31. (the one containing the directory /) is located on a SCSI device.
  32. config SCSI_DMA
  33. bool
  34. default n
  35. config SCSI_TGT
  36. tristate "SCSI target support"
  37. depends on SCSI && EXPERIMENTAL
  38. ---help---
  39. If you want to use SCSI target mode drivers enable this option.
  40. If you choose M, the module will be called scsi_tgt.
  41. config SCSI_NETLINK
  42. bool
  43. default n
  44. select NET
  45. config SCSI_PROC_FS
  46. bool "legacy /proc/scsi/ support"
  47. depends on SCSI && PROC_FS
  48. default y
  49. ---help---
  50. This option enables support for the various files in
  51. /proc/scsi. In Linux 2.6 this has been superseded by
  52. files in sysfs but many legacy applications rely on this.
  53. If unsure say Y.
  54. comment "SCSI support type (disk, tape, CD-ROM)"
  55. depends on SCSI
  56. config BLK_DEV_SD
  57. tristate "SCSI disk support"
  58. depends on SCSI
  59. select CRC_T10DIF if BLK_DEV_INTEGRITY
  60. ---help---
  61. If you want to use SCSI hard disks, Fibre Channel disks,
  62. Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
  63. USB storage or the SCSI or parallel port version of
  64. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  65. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  66. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  67. CD-ROMs.
  68. To compile this driver as a module, choose M here and read
  69. <file:Documentation/scsi/scsi.txt>.
  70. The module will be called sd_mod.
  71. Do not compile this driver as a module if your root file system
  72. (the one containing the directory /) is located on a SCSI disk.
  73. In this case, do not compile the driver for your SCSI host adapter
  74. (below) as a module either.
  75. config CHR_DEV_ST
  76. tristate "SCSI tape support"
  77. depends on SCSI
  78. ---help---
  79. If you want to use a SCSI tape drive under Linux, say Y and read the
  80. SCSI-HOWTO, available from
  81. <http://www.tldp.org/docs.html#howto>, and
  82. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  83. for SCSI CD-ROMs.
  84. To compile this driver as a module, choose M here and read
  85. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  86. config CHR_DEV_OSST
  87. tristate "SCSI OnStream SC-x0 tape support"
  88. depends on SCSI
  89. ---help---
  90. The OnStream SC-x0 SCSI tape drives cannot be driven by the
  91. standard st driver, but instead need this special osst driver and
  92. use the /dev/osstX char device nodes (major 206). Via usb-storage,
  93. you may be able to drive the USB-x0 and DI-x0 drives as well.
  94. Note that there is also a second generation of OnStream
  95. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  96. tapes (QIC-157) and can be driven by the standard driver st.
  97. For more information, you may have a look at the SCSI-HOWTO
  98. <http://www.tldp.org/docs.html#howto> and
  99. <file:Documentation/scsi/osst.txt> in the kernel source.
  100. More info on the OnStream driver may be found on
  101. <http://sourceforge.net/projects/osst/>
  102. Please also have a look at the standard st docu, as most of it
  103. applies to osst as well.
  104. To compile this driver as a module, choose M here and read
  105. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  106. config BLK_DEV_SR
  107. tristate "SCSI CDROM support"
  108. depends on SCSI
  109. ---help---
  110. If you want to use a CD or DVD drive attached to your computer
  111. by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
  112. and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
  113. Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
  114. To compile this driver as a module, choose M here and read
  115. <file:Documentation/scsi/scsi.txt>.
  116. The module will be called sr_mod.
  117. config BLK_DEV_SR_VENDOR
  118. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  119. depends on BLK_DEV_SR
  120. help
  121. This enables the usage of vendor specific SCSI commands. This is
  122. required to support multisession CDs with old NEC/TOSHIBA cdrom
  123. drives (and HP Writers). If you have such a drive and get the first
  124. session only, try saying Y here; everybody else says N.
  125. config CHR_DEV_SG
  126. tristate "SCSI generic support"
  127. depends on SCSI
  128. ---help---
  129. If you want to use SCSI scanners, synthesizers or CD-writers or just
  130. about anything having "SCSI" in its name other than hard disks,
  131. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  132. directly, so you need some additional software which knows how to
  133. talk to these devices using the SCSI protocol:
  134. For scanners, look at SANE (<http://www.sane-project.org/>). For CD
  135. writer software look at Cdrtools
  136. (<http://cdrecord.berlios.de/private/cdrecord.html>)
  137. and for burning a "disk at once": CDRDAO
  138. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  139. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  140. For other devices, it's possible that you'll have to write the
  141. driver software yourself. Please read the file
  142. <file:Documentation/scsi/scsi-generic.txt> for more information.
  143. To compile this driver as a module, choose M here and read
  144. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  145. If unsure, say N.
  146. config CHR_DEV_SCH
  147. tristate "SCSI media changer support"
  148. depends on SCSI
  149. ---help---
  150. This is a driver for SCSI media changers. Most common devices are
  151. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  152. don't need this for those tiny 6-slot cdrom changers. Media
  153. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  154. If you have such hardware and want to use it with linux, say Y
  155. here. Check <file:Documentation/scsi/scsi-changer.txt> for details.
  156. If you want to compile this as a module ( = code which can be
  157. inserted in and removed from the running kernel whenever you want),
  158. say M here and read <file:Documentation/kbuild/modules.txt> and
  159. <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
  160. If unsure, say N.
  161. config SCSI_ENCLOSURE
  162. tristate "SCSI Enclosure Support"
  163. depends on SCSI && ENCLOSURE_SERVICES
  164. help
  165. Enclosures are devices sitting on or in SCSI backplanes that
  166. manage devices. If you have a disk cage, the chances are that
  167. it has an enclosure device. Selecting this option will just allow
  168. certain enclosure conditions to be reported and is not required.
  169. config SCSI_MULTI_LUN
  170. bool "Probe all LUNs on each SCSI device"
  171. depends on SCSI
  172. help
  173. Some devices support more than one LUN (Logical Unit Number) in order
  174. to allow access to several media, e.g. CD jukebox, USB card reader,
  175. mobile phone in mass storage mode. This option forces the kernel to
  176. probe for all LUNs by default. This setting can be overriden by
  177. max_luns boot/module parameter. Note that this option does not affect
  178. devices conforming to SCSI-3 or higher as they can explicitely report
  179. their number of LUNs. It is safe to say Y here unless you have one of
  180. those rare devices which reacts in an unexpected way when probed for
  181. multiple LUNs.
  182. config SCSI_CONSTANTS
  183. bool "Verbose SCSI error reporting (kernel size +=12K)"
  184. depends on SCSI
  185. help
  186. The error messages regarding your SCSI hardware will be easier to
  187. understand if you say Y here; it will enlarge your kernel by about
  188. 12 KB. If in doubt, say Y.
  189. config SCSI_LOGGING
  190. bool "SCSI logging facility"
  191. depends on SCSI
  192. ---help---
  193. This turns on a logging facility that can be used to debug a number
  194. of SCSI related problems.
  195. If you say Y here, no logging output will appear by default, but you
  196. can enable logging by saying Y to "/proc file system support" and
  197. "Sysctl support" below and executing the command
  198. echo <bitmask> > /proc/sys/dev/scsi/logging_level
  199. where <bitmask> is a four byte value representing the logging type
  200. and logging level for each type of logging selected.
  201. There are a number of logging types and you can find them in the
  202. source at <file:drivers/scsi/scsi_logging.h>. The logging levels
  203. are also described in that file and they determine the verbosity of
  204. the logging for each logging type.
  205. If you say N here, it may be harder to track down some types of SCSI
  206. problems. If you say Y here your kernel will be somewhat larger, but
  207. there should be no noticeable performance impact as long as you have
  208. logging turned off.
  209. config SCSI_SCAN_ASYNC
  210. bool "Asynchronous SCSI scanning"
  211. depends on SCSI
  212. help
  213. The SCSI subsystem can probe for devices while the rest of the
  214. system continues booting, and even probe devices on different
  215. busses in parallel, leading to a significant speed-up.
  216. If you have built SCSI as modules, enabling this option can
  217. be a problem as the devices may not have been found by the
  218. time your system expects them to have been. You can load the
  219. scsi_wait_scan module to ensure that all scans have completed.
  220. If you build your SCSI drivers into the kernel, then everything
  221. will work fine if you say Y here.
  222. You can override this choice by specifying "scsi_mod.scan=sync"
  223. or async on the kernel's command line.
  224. config SCSI_WAIT_SCAN
  225. tristate # No prompt here, this is an invisible symbol.
  226. default m
  227. depends on SCSI
  228. depends on MODULES
  229. # scsi_wait_scan is a loadable module which waits until all the async scans are
  230. # complete. The idea is to use it in initrd/ initramfs scripts. You modprobe
  231. # it after all the modprobes of the root SCSI drivers and it will wait until
  232. # they have all finished scanning their buses before allowing the boot to
  233. # proceed. (This method is not applicable if targets boot independently in
  234. # parallel with the initiator, or with transports with non-deterministic target
  235. # discovery schemes, or if a transport driver does not support scsi_wait_scan.)
  236. #
  237. # This symbol is not exposed as a prompt because little is to be gained by
  238. # disabling it, whereas people who accidentally switch it off may wonder why
  239. # their mkinitrd gets into trouble.
  240. menu "SCSI Transports"
  241. depends on SCSI
  242. config SCSI_SPI_ATTRS
  243. tristate "Parallel SCSI (SPI) Transport Attributes"
  244. depends on SCSI
  245. help
  246. If you wish to export transport-specific information about
  247. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  248. config SCSI_FC_ATTRS
  249. tristate "FiberChannel Transport Attributes"
  250. depends on SCSI
  251. select SCSI_NETLINK
  252. help
  253. If you wish to export transport-specific information about
  254. each attached FiberChannel device to sysfs, say Y.
  255. Otherwise, say N.
  256. config SCSI_FC_TGT_ATTRS
  257. bool "SCSI target support for FiberChannel Transport Attributes"
  258. depends on SCSI_FC_ATTRS
  259. depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
  260. help
  261. If you want to use SCSI target mode drivers enable this option.
  262. config SCSI_ISCSI_ATTRS
  263. tristate "iSCSI Transport Attributes"
  264. depends on SCSI && NET
  265. select BLK_DEV_BSGLIB
  266. help
  267. If you wish to export transport-specific information about
  268. each attached iSCSI device to sysfs, say Y.
  269. Otherwise, say N.
  270. config SCSI_SAS_ATTRS
  271. tristate "SAS Transport Attributes"
  272. depends on SCSI
  273. select BLK_DEV_BSG
  274. help
  275. If you wish to export transport-specific information about
  276. each attached SAS device to sysfs, say Y.
  277. source "drivers/scsi/libsas/Kconfig"
  278. config SCSI_SRP_ATTRS
  279. tristate "SRP Transport Attributes"
  280. depends on SCSI
  281. help
  282. If you wish to export transport-specific information about
  283. each attached SRP device to sysfs, say Y.
  284. config SCSI_SRP_TGT_ATTRS
  285. bool "SCSI target support for SRP Transport Attributes"
  286. depends on SCSI_SRP_ATTRS
  287. depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
  288. help
  289. If you want to use SCSI target mode drivers enable this option.
  290. endmenu
  291. menuconfig SCSI_LOWLEVEL
  292. bool "SCSI low-level drivers"
  293. depends on SCSI!=n
  294. default y
  295. if SCSI_LOWLEVEL && SCSI
  296. config ISCSI_TCP
  297. tristate "iSCSI Initiator over TCP/IP"
  298. depends on SCSI && INET
  299. select CRYPTO
  300. select CRYPTO_MD5
  301. select CRYPTO_CRC32C
  302. select SCSI_ISCSI_ATTRS
  303. help
  304. The iSCSI Driver provides a host with the ability to access storage
  305. through an IP network. The driver uses the iSCSI protocol to transport
  306. SCSI requests and responses over a TCP/IP network between the host
  307. (the "initiator") and "targets". Architecturally, the iSCSI driver
  308. combines with the host's TCP/IP stack, network drivers, and Network
  309. Interface Card (NIC) to provide the same functions as a SCSI or a
  310. Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
  311. To compile this driver as a module, choose M here: the
  312. module will be called iscsi_tcp.
  313. The userspace component needed to initialize the driver, documentation,
  314. and sample configuration files can be found here:
  315. http://open-iscsi.org
  316. config ISCSI_BOOT_SYSFS
  317. tristate "iSCSI Boot Sysfs Interface"
  318. default n
  319. help
  320. This option enables support for exposing iSCSI boot information
  321. via sysfs to userspace. If you wish to export this information,
  322. say Y. Otherwise, say N.
  323. source "drivers/scsi/cxgbi/Kconfig"
  324. source "drivers/scsi/bnx2i/Kconfig"
  325. source "drivers/scsi/bnx2fc/Kconfig"
  326. source "drivers/scsi/be2iscsi/Kconfig"
  327. config SGIWD93_SCSI
  328. tristate "SGI WD93C93 SCSI Driver"
  329. depends on SGI_HAS_WD93 && SCSI
  330. help
  331. If you have a Western Digital WD93 SCSI controller on
  332. an SGI MIPS system, say Y. Otherwise, say N.
  333. config BLK_DEV_3W_XXXX_RAID
  334. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  335. depends on PCI && SCSI
  336. help
  337. 3ware is the only hardware ATA-Raid product in Linux to date.
  338. This card is 2,4, or 8 channel master mode support only.
  339. SCSI support required!!!
  340. <http://www.3ware.com/>
  341. Please read the comments at the top of
  342. <file:drivers/scsi/3w-xxxx.c>.
  343. config SCSI_HPSA
  344. tristate "HP Smart Array SCSI driver"
  345. depends on PCI && SCSI
  346. help
  347. This driver supports HP Smart Array Controllers (circa 2009).
  348. It is a SCSI alternative to the cciss driver, which is a block
  349. driver. Anyone wishing to use HP Smart Array controllers who
  350. would prefer the devices be presented to linux as SCSI devices,
  351. rather than as generic block devices should say Y here.
  352. config SCSI_3W_9XXX
  353. tristate "3ware 9xxx SATA-RAID support"
  354. depends on PCI && SCSI
  355. help
  356. This driver supports the 9000 series 3ware SATA-RAID cards.
  357. <http://www.amcc.com>
  358. Please read the comments at the top of
  359. <file:drivers/scsi/3w-9xxx.c>.
  360. config SCSI_3W_SAS
  361. tristate "3ware 97xx SAS/SATA-RAID support"
  362. depends on PCI && SCSI
  363. help
  364. This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
  365. <http://www.lsi.com>
  366. Please read the comments at the top of
  367. <file:drivers/scsi/3w-sas.c>.
  368. config SCSI_7000FASST
  369. tristate "7000FASST SCSI support"
  370. depends on ISA && SCSI && ISA_DMA_API
  371. select CHECK_SIGNATURE
  372. help
  373. This driver supports the Western Digital 7000 SCSI host adapter
  374. family. Some information is in the source:
  375. <file:drivers/scsi/wd7000.c>.
  376. To compile this driver as a module, choose M here: the
  377. module will be called wd7000.
  378. config SCSI_ACARD
  379. tristate "ACARD SCSI support"
  380. depends on PCI && SCSI
  381. help
  382. This driver supports the ACARD SCSI host adapter.
  383. Support Chip <ATP870 ATP876 ATP880 ATP885>
  384. To compile this driver as a module, choose M here: the
  385. module will be called atp870u.
  386. config SCSI_AHA152X
  387. tristate "Adaptec AHA152X/2825 support"
  388. depends on ISA && SCSI && !64BIT
  389. select SCSI_SPI_ATTRS
  390. select CHECK_SIGNATURE
  391. ---help---
  392. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  393. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  394. must be manually specified in this case.
  395. It is explained in section 3.3 of the SCSI-HOWTO, available from
  396. <http://www.tldp.org/docs.html#howto>. You might also want to
  397. read the file <file:Documentation/scsi/aha152x.txt>.
  398. To compile this driver as a module, choose M here: the
  399. module will be called aha152x.
  400. config SCSI_AHA1542
  401. tristate "Adaptec AHA1542 support"
  402. depends on ISA && SCSI && ISA_DMA_API
  403. ---help---
  404. This is support for a SCSI host adapter. It is explained in section
  405. 3.4 of the SCSI-HOWTO, available from
  406. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  407. purchased by Adaptec, and some former Trantor products are being
  408. sold under the Adaptec name. If it doesn't work out of the box, you
  409. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  410. To compile this driver as a module, choose M here: the
  411. module will be called aha1542.
  412. config SCSI_AHA1740
  413. tristate "Adaptec AHA1740 support"
  414. depends on EISA && SCSI
  415. ---help---
  416. This is support for a SCSI host adapter. It is explained in section
  417. 3.5 of the SCSI-HOWTO, available from
  418. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  419. of the box, you may have to change some settings in
  420. <file:drivers/scsi/aha1740.h>.
  421. To compile this driver as a module, choose M here: the
  422. module will be called aha1740.
  423. config SCSI_AACRAID
  424. tristate "Adaptec AACRAID support"
  425. depends on SCSI && PCI
  426. help
  427. This driver supports a variety of Dell, HP, Adaptec, IBM and
  428. ICP storage products. For a list of supported products, refer
  429. to <file:Documentation/scsi/aacraid.txt>.
  430. To compile this driver as a module, choose M here: the module
  431. will be called aacraid.
  432. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  433. config SCSI_AIC7XXX_OLD
  434. tristate "Adaptec AIC7xxx support (old driver)"
  435. depends on (ISA || EISA || PCI ) && SCSI
  436. help
  437. WARNING This driver is an older aic7xxx driver and is no longer
  438. under active development. Adaptec, Inc. is writing a new driver to
  439. take the place of this one, and it is recommended that whenever
  440. possible, people should use the new Adaptec written driver instead
  441. of this one. This driver will eventually be phased out entirely.
  442. This is support for the various aic7xxx based Adaptec SCSI
  443. controllers. These include the 274x EISA cards; 284x VLB cards;
  444. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  445. motherboard based SCSI controllers from Adaptec. It does not support
  446. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  447. support them. It does not support the 2920 cards from Adaptec that
  448. use the Future Domain SCSI controller chip. For those cards, you
  449. need the "Future Domain 16xx SCSI support" driver.
  450. In general, if the controller is based on an Adaptec SCSI controller
  451. chip from the aic777x series or the aic78xx series, this driver
  452. should work. The only exception is the 7810 which is specifically
  453. not supported (that's the RAID controller chip on the AAA-13x
  454. cards).
  455. Note that the AHA2920 SCSI host adapter is *not* supported by this
  456. driver; choose "Future Domain 16xx SCSI support" instead if you have
  457. one of those.
  458. Information on the configuration options for this controller can be
  459. found by checking the help file for each of the available
  460. configuration options. You should read
  461. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  462. contacting the maintainer with any questions. The SCSI-HOWTO,
  463. available from <http://www.tldp.org/docs.html#howto>, can also
  464. be of great help.
  465. To compile this driver as a module, choose M here: the
  466. module will be called aic7xxx_old.
  467. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  468. source "drivers/scsi/aic94xx/Kconfig"
  469. source "drivers/scsi/mvsas/Kconfig"
  470. config SCSI_MVUMI
  471. tristate "Marvell UMI driver"
  472. depends on SCSI && PCI
  473. help
  474. Module for Marvell Universal Message Interface(UMI) driver
  475. To compile this driver as a module, choose M here: the
  476. module will be called mvumi.
  477. config SCSI_DPT_I2O
  478. tristate "Adaptec I2O RAID support "
  479. depends on SCSI && PCI && VIRT_TO_BUS
  480. help
  481. This driver supports all of Adaptec's I2O based RAID controllers as
  482. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  483. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  484. To compile this driver as a module, choose M here: the
  485. module will be called dpt_i2o.
  486. config SCSI_ADVANSYS
  487. tristate "AdvanSys SCSI support"
  488. depends on SCSI && VIRT_TO_BUS
  489. depends on ISA || EISA || PCI
  490. help
  491. This is a driver for all SCSI host adapters manufactured by
  492. AdvanSys. It is documented in the kernel source in
  493. <file:drivers/scsi/advansys.c>.
  494. To compile this driver as a module, choose M here: the
  495. module will be called advansys.
  496. config SCSI_IN2000
  497. tristate "Always IN2000 SCSI support"
  498. depends on ISA && SCSI
  499. help
  500. This is support for an ISA bus SCSI host adapter. You'll find more
  501. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  502. out of the box, you may have to change the jumpers for IRQ or
  503. address selection.
  504. To compile this driver as a module, choose M here: the
  505. module will be called in2000.
  506. config SCSI_ARCMSR
  507. tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
  508. depends on PCI && SCSI
  509. help
  510. This driver supports all of ARECA's SATA/SAS RAID controller cards.
  511. This is an ARECA-maintained driver by Erich Chen.
  512. If you have any problems, please mail to: <erich@areca.com.tw>.
  513. Areca supports Linux RAID config tools.
  514. Please link <http://www.areca.com.tw>
  515. To compile this driver as a module, choose M here: the
  516. module will be called arcmsr (modprobe arcmsr).
  517. source "drivers/scsi/megaraid/Kconfig.megaraid"
  518. source "drivers/scsi/mpt2sas/Kconfig"
  519. config SCSI_HPTIOP
  520. tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
  521. depends on SCSI && PCI
  522. help
  523. This option enables support for HighPoint RocketRAID 3xxx/4xxx
  524. controllers.
  525. To compile this driver as a module, choose M here; the module
  526. will be called hptiop. If unsure, say N.
  527. config SCSI_BUSLOGIC
  528. tristate "BusLogic SCSI support"
  529. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
  530. ---help---
  531. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  532. Adapters. Consult the SCSI-HOWTO, available from
  533. <http://www.tldp.org/docs.html#howto>, and the files
  534. <file:Documentation/scsi/BusLogic.txt> and
  535. <file:Documentation/scsi/FlashPoint.txt> for more information.
  536. Note that support for FlashPoint is only available for 32-bit
  537. x86 configurations.
  538. To compile this driver as a module, choose M here: the
  539. module will be called BusLogic.
  540. config SCSI_FLASHPOINT
  541. bool "FlashPoint support"
  542. depends on SCSI_BUSLOGIC && PCI && X86_32
  543. help
  544. This option allows you to add FlashPoint support to the
  545. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  546. substantial, so users of MultiMaster Host Adapters may not
  547. wish to include it.
  548. config VMWARE_PVSCSI
  549. tristate "VMware PVSCSI driver support"
  550. depends on PCI && SCSI && X86
  551. help
  552. This driver supports VMware's para virtualized SCSI HBA.
  553. To compile this driver as a module, choose M here: the
  554. module will be called vmw_pvscsi.
  555. config LIBFC
  556. tristate "LibFC module"
  557. select SCSI_FC_ATTRS
  558. select CRC32
  559. ---help---
  560. Fibre Channel library module
  561. config LIBFCOE
  562. tristate "LibFCoE module"
  563. select LIBFC
  564. ---help---
  565. Library for Fibre Channel over Ethernet module
  566. config FCOE
  567. tristate "FCoE module"
  568. depends on PCI
  569. select LIBFCOE
  570. ---help---
  571. Fibre Channel over Ethernet module
  572. config FCOE_FNIC
  573. tristate "Cisco FNIC Driver"
  574. depends on PCI && X86
  575. select LIBFCOE
  576. help
  577. This is support for the Cisco PCI-Express FCoE HBA.
  578. To compile this driver as a module, choose M here and read
  579. <file:Documentation/scsi/scsi.txt>.
  580. The module will be called fnic.
  581. config SCSI_DMX3191D
  582. tristate "DMX3191D SCSI support"
  583. depends on PCI && SCSI
  584. select SCSI_SPI_ATTRS
  585. help
  586. This is support for Domex DMX3191D SCSI Host Adapters.
  587. To compile this driver as a module, choose M here: the
  588. module will be called dmx3191d.
  589. config SCSI_DTC3280
  590. tristate "DTC3180/3280 SCSI support"
  591. depends on ISA && SCSI
  592. select SCSI_SPI_ATTRS
  593. select CHECK_SIGNATURE
  594. help
  595. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  596. the SCSI-HOWTO, available from
  597. <http://www.tldp.org/docs.html#howto>, and the file
  598. <file:Documentation/scsi/dtc3x80.txt>.
  599. To compile this driver as a module, choose M here: the
  600. module will be called dtc.
  601. config SCSI_EATA
  602. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  603. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  604. ---help---
  605. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  606. ISA and all EISA I/O addresses are probed looking for the "EATA"
  607. signature. The addresses of all the PCI SCSI controllers reported
  608. by the PCI subsystem are probed as well.
  609. You want to read the start of <file:drivers/scsi/eata.c> and the
  610. SCSI-HOWTO, available from
  611. <http://www.tldp.org/docs.html#howto>.
  612. To compile this driver as a module, choose M here: the
  613. module will be called eata.
  614. config SCSI_EATA_TAGGED_QUEUE
  615. bool "enable tagged command queueing"
  616. depends on SCSI_EATA
  617. help
  618. This is a feature of SCSI-2 which improves performance: the host
  619. adapter can send several SCSI commands to a device's queue even if
  620. previous commands haven't finished yet.
  621. This is equivalent to the "eata=tc:y" boot option.
  622. config SCSI_EATA_LINKED_COMMANDS
  623. bool "enable elevator sorting"
  624. depends on SCSI_EATA
  625. help
  626. This option enables elevator sorting for all probed SCSI disks and
  627. CD-ROMs. It definitely reduces the average seek distance when doing
  628. random seeks, but this does not necessarily result in a noticeable
  629. performance improvement: your mileage may vary...
  630. This is equivalent to the "eata=lc:y" boot option.
  631. config SCSI_EATA_MAX_TAGS
  632. int "maximum number of queued commands"
  633. depends on SCSI_EATA
  634. default "16"
  635. help
  636. This specifies how many SCSI commands can be maximally queued for
  637. each probed SCSI device. You should reduce the default value of 16
  638. only if you have disks with buggy or limited tagged command support.
  639. Minimum is 2 and maximum is 62. This value is also the window size
  640. used by the elevator sorting option above. The effective value used
  641. by the driver for each probed SCSI device is reported at boot time.
  642. This is equivalent to the "eata=mq:8" boot option.
  643. config SCSI_EATA_PIO
  644. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  645. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  646. ---help---
  647. This driver supports all EATA-PIO protocol compliant SCSI Host
  648. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  649. host adapters could also use this driver but are discouraged from
  650. doing so, since this driver only supports hard disks and lacks
  651. numerous features. You might want to have a look at the SCSI-HOWTO,
  652. available from <http://www.tldp.org/docs.html#howto>.
  653. To compile this driver as a module, choose M here: the
  654. module will be called eata_pio.
  655. config SCSI_FUTURE_DOMAIN
  656. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  657. depends on (ISA || PCI) && SCSI
  658. select CHECK_SIGNATURE
  659. ---help---
  660. This is support for Future Domain's 16-bit SCSI host adapters
  661. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  662. other adapters based on the Future Domain chipsets (Quantum
  663. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  664. It is explained in section 3.7 of the SCSI-HOWTO, available from
  665. <http://www.tldp.org/docs.html#howto>.
  666. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  667. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  668. controller support"). This Future Domain driver works with the older
  669. Adaptec AHA-2920A boards with a Future Domain chip on them.
  670. To compile this driver as a module, choose M here: the
  671. module will be called fdomain.
  672. config SCSI_FD_MCS
  673. tristate "Future Domain MCS-600/700 SCSI support"
  674. depends on MCA_LEGACY && SCSI
  675. ---help---
  676. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  677. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  678. is identical to the MCS 700 and hence also supported by this driver.
  679. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  680. It supports multiple adapters in the same system.
  681. To compile this driver as a module, choose M here: the
  682. module will be called fd_mcs.
  683. config SCSI_GDTH
  684. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  685. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  686. ---help---
  687. Formerly called GDT SCSI Disk Array Controller Support.
  688. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  689. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  690. in the kernel source in <file:drivers/scsi/gdth.c> and
  691. <file:drivers/scsi/gdth.h>.
  692. To compile this driver as a module, choose M here: the
  693. module will be called gdth.
  694. config SCSI_ISCI
  695. tristate "Intel(R) C600 Series Chipset SAS Controller"
  696. depends on PCI && SCSI
  697. depends on X86
  698. # (temporary): known alpha quality driver
  699. depends on EXPERIMENTAL
  700. select SCSI_SAS_LIBSAS
  701. select SCSI_SAS_HOST_SMP
  702. ---help---
  703. This driver supports the 6Gb/s SAS capabilities of the storage
  704. control unit found in the Intel(R) C600 series chipset.
  705. The experimental tag will be removed after the driver exits alpha
  706. config SCSI_GENERIC_NCR5380
  707. tristate "Generic NCR5380/53c400 SCSI PIO support"
  708. depends on ISA && SCSI
  709. select SCSI_SPI_ATTRS
  710. ---help---
  711. This is a driver for the old NCR 53c80 series of SCSI controllers
  712. on boards using PIO. Most boards such as the Trantor T130 fit this
  713. category, along with a large number of ISA 8bit controllers shipped
  714. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  715. you should select the specific driver for that card rather than
  716. generic 5380 support.
  717. It is explained in section 3.8 of the SCSI-HOWTO, available from
  718. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  719. of the box, you may have to change some settings in
  720. <file:drivers/scsi/g_NCR5380.h>.
  721. To compile this driver as a module, choose M here: the
  722. module will be called g_NCR5380.
  723. config SCSI_GENERIC_NCR5380_MMIO
  724. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  725. depends on ISA && SCSI
  726. select SCSI_SPI_ATTRS
  727. ---help---
  728. This is a driver for the old NCR 53c80 series of SCSI controllers
  729. on boards using memory mapped I/O.
  730. It is explained in section 3.8 of the SCSI-HOWTO, available from
  731. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  732. of the box, you may have to change some settings in
  733. <file:drivers/scsi/g_NCR5380.h>.
  734. To compile this driver as a module, choose M here: the
  735. module will be called g_NCR5380_mmio.
  736. config SCSI_GENERIC_NCR53C400
  737. bool "Enable NCR53c400 extensions"
  738. depends on SCSI_GENERIC_NCR5380
  739. help
  740. This enables certain optimizations for the NCR53c400 SCSI cards.
  741. You might as well try it out. Note that this driver will only probe
  742. for the Trantor T130B in its default configuration; you might have
  743. to pass a command line option to the kernel at boot time if it does
  744. not detect your card. See the file
  745. <file:Documentation/scsi/g_NCR5380.txt> for details.
  746. config SCSI_IBMMCA
  747. tristate "IBMMCA SCSI support"
  748. depends on MCA && SCSI
  749. ---help---
  750. This is support for the IBM SCSI adapter found in many of the PS/2
  751. series computers. These machines have an MCA bus, so you need to
  752. answer Y to "MCA support" as well and read
  753. <file:Documentation/mca.txt>.
  754. If the adapter isn't found during boot (a common problem for models
  755. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  756. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  757. if that doesn't work check your reference diskette). Owners of
  758. model 95 with a LED-matrix-display can in addition activate some
  759. activity info like under OS/2, but more informative, by setting
  760. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  761. bootparam" or see the documentation of your boot loader about how to
  762. pass options to the kernel.
  763. To compile this driver as a module, choose M here: the
  764. module will be called ibmmca.
  765. config IBMMCA_SCSI_ORDER_STANDARD
  766. bool "Standard SCSI-order"
  767. depends on SCSI_IBMMCA
  768. ---help---
  769. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  770. are assigned to the drive letters, starting with the lowest SCSI-id
  771. (physical number -- pun) to be drive C:, as seen from DOS and
  772. similar operating systems. When looking into papers describing the
  773. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  774. The SCSI-standard follows a hardware-hierarchy which says that id 7
  775. has the highest priority and id 0 the lowest. Therefore, the host
  776. adapters are still today everywhere placed as SCSI-id 7 by default.
  777. In the SCSI-standard, the drive letters express the priority of the
  778. disk. C: should be the hard disk, or a partition on it, with the
  779. highest priority. This must therefore be the disk with the highest
  780. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  781. original definition of the SCSI-standard as also industrial- and
  782. process-control-machines, like VME-CPUs running under realtime-OSes
  783. (e.g. LynxOS, OS9) do.
  784. If you like to run Linux on your MCA-machine with the same
  785. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  786. machine, which is in addition conformant to the SCSI-standard, you
  787. must say Y here. This is also necessary for MCA-Linux users who want
  788. to keep downward compatibility to older releases of the
  789. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  790. June 1997).
  791. If you like to have the lowest SCSI-id assigned as drive C:, as
  792. modern SCSI-BIOSes do, which does not conform to the standard, but
  793. is widespread and common in the PC-world of today, you must say N
  794. here. If unsure, say Y.
  795. config IBMMCA_SCSI_DEV_RESET
  796. bool "Reset SCSI-devices at boottime"
  797. depends on SCSI_IBMMCA
  798. ---help---
  799. By default, SCSI-devices are reset when the machine is powered on.
  800. However, some devices exist, like special-control-devices,
  801. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  802. not reset when switched on. If you say Y here, each device connected
  803. to your SCSI-bus will be issued a reset-command after it has been
  804. probed, while the kernel is booting. This may cause problems with
  805. more modern devices, like hard disks, which do not appreciate these
  806. reset commands, and can cause your system to hang. So say Y only if
  807. you know that one of your older devices needs it; N is the safe
  808. answer.
  809. config SCSI_IPS
  810. tristate "IBM ServeRAID support"
  811. depends on PCI && SCSI
  812. ---help---
  813. This is support for the IBM ServeRAID hardware RAID controllers.
  814. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  815. and <http://www-947.ibm.com/support/entry/portal/docdisplay?brand=5000008&lndocid=SERV-RAID>
  816. for more information. If this driver does not work correctly
  817. without modification please contact the author by email at
  818. <ipslinux@adaptec.com>.
  819. To compile this driver as a module, choose M here: the
  820. module will be called ips.
  821. config SCSI_IBMVSCSI
  822. tristate "IBM Virtual SCSI support"
  823. depends on PPC_PSERIES || PPC_ISERIES
  824. select SCSI_SRP_ATTRS
  825. select VIOPATH if PPC_ISERIES
  826. help
  827. This is the IBM POWER Virtual SCSI Client
  828. To compile this driver as a module, choose M here: the
  829. module will be called ibmvscsic.
  830. config SCSI_IBMVSCSIS
  831. tristate "IBM Virtual SCSI Server support"
  832. depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
  833. help
  834. This is the SRP target driver for IBM pSeries virtual environments.
  835. The userspace component needed to initialize the driver and
  836. documentation can be found:
  837. http://stgt.berlios.de/
  838. To compile this driver as a module, choose M here: the
  839. module will be called ibmvstgt.
  840. config SCSI_IBMVFC
  841. tristate "IBM Virtual FC support"
  842. depends on PPC_PSERIES && SCSI
  843. select SCSI_FC_ATTRS
  844. help
  845. This is the IBM POWER Virtual FC Client
  846. To compile this driver as a module, choose M here: the
  847. module will be called ibmvfc.
  848. config SCSI_IBMVFC_TRACE
  849. bool "enable driver internal trace"
  850. depends on SCSI_IBMVFC
  851. default y
  852. help
  853. If you say Y here, the driver will trace all commands issued
  854. to the adapter. Performance impact is minimal. Trace can be
  855. dumped using /sys/class/scsi_host/hostXX/trace.
  856. config SCSI_INITIO
  857. tristate "Initio 9100U(W) support"
  858. depends on PCI && SCSI
  859. help
  860. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  861. read the SCSI-HOWTO, available from
  862. <http://www.tldp.org/docs.html#howto>.
  863. To compile this driver as a module, choose M here: the
  864. module will be called initio.
  865. config SCSI_INIA100
  866. tristate "Initio INI-A100U2W support"
  867. depends on PCI && SCSI
  868. help
  869. This is support for the Initio INI-A100U2W SCSI host adapter.
  870. Please read the SCSI-HOWTO, available from
  871. <http://www.tldp.org/docs.html#howto>.
  872. To compile this driver as a module, choose M here: the
  873. module will be called a100u2w.
  874. config SCSI_PPA
  875. tristate "IOMEGA parallel port (ppa - older drives)"
  876. depends on SCSI && PARPORT_PC
  877. ---help---
  878. This driver supports older versions of IOMEGA's parallel port ZIP
  879. drive (a 100 MB removable media device).
  880. Note that you can say N here if you have the SCSI version of the ZIP
  881. drive: it will be supported automatically if you said Y to the
  882. generic "SCSI disk support", above.
  883. If you have the ZIP Plus drive or a more recent parallel port ZIP
  884. drive (if the supplied cable with the drive is labeled "AutoDetect")
  885. then you should say N here and Y to "IOMEGA parallel port (imm -
  886. newer drives)", below.
  887. For more information about this driver and how to use it you should
  888. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  889. the SCSI-HOWTO, which is available from
  890. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  891. you will still be able to use the parallel port for other tasks,
  892. such as a printer; it is safe to compile both drivers into the
  893. kernel.
  894. To compile this driver as a module, choose M here: the
  895. module will be called ppa.
  896. config SCSI_IMM
  897. tristate "IOMEGA parallel port (imm - newer drives)"
  898. depends on SCSI && PARPORT_PC
  899. ---help---
  900. This driver supports newer versions of IOMEGA's parallel port ZIP
  901. drive (a 100 MB removable media device).
  902. Note that you can say N here if you have the SCSI version of the ZIP
  903. drive: it will be supported automatically if you said Y to the
  904. generic "SCSI disk support", above.
  905. If you have the ZIP Plus drive or a more recent parallel port ZIP
  906. drive (if the supplied cable with the drive is labeled "AutoDetect")
  907. then you should say Y here; if you have an older ZIP drive, say N
  908. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  909. For more information about this driver and how to use it you should
  910. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  911. the SCSI-HOWTO, which is available from
  912. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  913. you will still be able to use the parallel port for other tasks,
  914. such as a printer; it is safe to compile both drivers into the
  915. kernel.
  916. To compile this driver as a module, choose M here: the
  917. module will be called imm.
  918. config SCSI_IZIP_EPP16
  919. bool "ppa/imm option - Use slow (but safe) EPP-16"
  920. depends on SCSI_PPA || SCSI_IMM
  921. ---help---
  922. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  923. allows them to act as expansion buses that can handle up to 64
  924. peripheral devices.
  925. Some parallel port chipsets are slower than their motherboard, and
  926. so we have to control the state of the chipset's FIFO queue every
  927. now and then to avoid data loss. This will be done if you say Y
  928. here.
  929. Generally, saying Y is the safe option and slows things down a bit.
  930. config SCSI_IZIP_SLOW_CTR
  931. bool "ppa/imm option - Assume slow parport control register"
  932. depends on SCSI_PPA || SCSI_IMM
  933. help
  934. Some parallel ports are known to have excessive delays between
  935. changing the parallel port control register and good data being
  936. available on the parallel port data/status register. This option
  937. forces a small delay (1.0 usec to be exact) after changing the
  938. control register to let things settle out. Enabling this option may
  939. result in a big drop in performance but some very old parallel ports
  940. (found in 386 vintage machines) will not work properly.
  941. Generally, saying N is fine.
  942. config SCSI_NCR53C406A
  943. tristate "NCR53c406a SCSI support"
  944. depends on ISA && SCSI
  945. help
  946. This is support for the NCR53c406a SCSI host adapter. For user
  947. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  948. in the kernel source. Also read the SCSI-HOWTO, available from
  949. <http://www.tldp.org/docs.html#howto>.
  950. To compile this driver as a module, choose M here: the
  951. module will be called NCR53c406.
  952. config SCSI_NCR_D700
  953. tristate "NCR Dual 700 MCA SCSI support"
  954. depends on MCA && SCSI
  955. select SCSI_SPI_ATTRS
  956. help
  957. This is a driver for the MicroChannel Dual 700 card produced by
  958. NCR and commonly used in 345x/35xx/4100 class machines. It always
  959. tries to negotiate sync and uses tag command queueing.
  960. Unless you have an NCR manufactured machine, the chances are that
  961. you do not have this SCSI card, so say N.
  962. config SCSI_LASI700
  963. tristate "HP Lasi SCSI support for 53c700/710"
  964. depends on GSC && SCSI
  965. select SCSI_SPI_ATTRS
  966. help
  967. This is a driver for the SCSI controller in the Lasi chip found in
  968. many PA-RISC workstations & servers. If you do not know whether you
  969. have a Lasi chip, it is safe to say "Y" here.
  970. config SCSI_SNI_53C710
  971. tristate "SNI RM SCSI support for 53c710"
  972. depends on SNI_RM && SCSI
  973. select SCSI_SPI_ATTRS
  974. select 53C700_LE_ON_BE
  975. help
  976. This is a driver for the onboard SCSI controller found in older
  977. SNI RM workstations & servers.
  978. config 53C700_LE_ON_BE
  979. bool
  980. depends on SCSI_LASI700
  981. default y
  982. config SCSI_STEX
  983. tristate "Promise SuperTrak EX Series support"
  984. depends on PCI && SCSI
  985. ---help---
  986. This driver supports Promise SuperTrak EX series storage controllers.
  987. Promise provides Linux RAID configuration utility for these
  988. controllers. Please visit <http://www.promise.com> to download.
  989. To compile this driver as a module, choose M here: the
  990. module will be called stex.
  991. config 53C700_BE_BUS
  992. bool
  993. depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
  994. default y
  995. config SCSI_SYM53C8XX_2
  996. tristate "SYM53C8XX Version 2 SCSI support"
  997. depends on PCI && SCSI
  998. select SCSI_SPI_ATTRS
  999. ---help---
  1000. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  1001. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  1002. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  1003. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  1004. controllers; you need to use the Fusion MPT driver for that.
  1005. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  1006. information.
  1007. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  1008. int "DMA addressing mode"
  1009. depends on SCSI_SYM53C8XX_2
  1010. default "1"
  1011. ---help---
  1012. This option only applies to PCI-SCSI chips that are PCI DAC
  1013. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  1014. When set to 0, the driver will program the chip to only perform
  1015. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  1016. to addresses up to 1TB. When set to 2, the driver supports the
  1017. full 64-bit DMA address range, but can only address 16 segments
  1018. of 4 GB each. This limits the total addressable range to 64 GB.
  1019. Most machines with less than 4GB of memory should use a setting
  1020. of 0 for best performance. If your machine has 4GB of memory
  1021. or more, you should set this option to 1 (the default).
  1022. The still experimental value 2 (64 bit DMA addressing with 16
  1023. x 4GB segments limitation) can be used on systems that require
  1024. PCI address bits past bit 39 to be set for the addressing of
  1025. memory using PCI DAC cycles.
  1026. config SCSI_SYM53C8XX_DEFAULT_TAGS
  1027. int "Default tagged command queue depth"
  1028. depends on SCSI_SYM53C8XX_2
  1029. default "16"
  1030. help
  1031. This is the default value of the command queue depth the
  1032. driver will announce to the generic SCSI layer for devices
  1033. that support tagged command queueing. This value can be changed
  1034. from the boot command line. This is a soft limit that cannot
  1035. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  1036. config SCSI_SYM53C8XX_MAX_TAGS
  1037. int "Maximum number of queued commands"
  1038. depends on SCSI_SYM53C8XX_2
  1039. default "64"
  1040. help
  1041. This option allows you to specify the maximum number of commands
  1042. that can be queued to any device, when tagged command queuing is
  1043. possible. The driver supports up to 256 queued commands per device.
  1044. This value is used as a compiled-in hard limit.
  1045. config SCSI_SYM53C8XX_MMIO
  1046. bool "Use memory mapped IO"
  1047. depends on SCSI_SYM53C8XX_2
  1048. default y
  1049. help
  1050. Memory mapped IO is faster than Port IO. Most people should
  1051. answer Y here, but some machines may have problems. If you have
  1052. to answer N here, please report the problem to the maintainer.
  1053. config SCSI_IPR
  1054. tristate "IBM Power Linux RAID adapter support"
  1055. depends on PCI && SCSI && ATA
  1056. select FW_LOADER
  1057. ---help---
  1058. This driver supports the IBM Power Linux family RAID adapters.
  1059. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  1060. as IBM iSeries 5702, 5703, 5709, and 570A.
  1061. config SCSI_IPR_TRACE
  1062. bool "enable driver internal trace"
  1063. depends on SCSI_IPR
  1064. default y
  1065. help
  1066. If you say Y here, the driver will trace all commands issued
  1067. to the adapter. Performance impact is minimal. Trace can be
  1068. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  1069. config SCSI_IPR_DUMP
  1070. bool "enable adapter dump support"
  1071. depends on SCSI_IPR
  1072. default y
  1073. help
  1074. If you say Y here, the driver will support adapter crash dump.
  1075. If you enable this support, the iprdump daemon can be used
  1076. to capture adapter failure analysis information.
  1077. config SCSI_ZALON
  1078. tristate "Zalon SCSI support"
  1079. depends on GSC && SCSI
  1080. select SCSI_SPI_ATTRS
  1081. help
  1082. The Zalon is a GSC/HSC bus interface chip that sits between the
  1083. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  1084. C110, J200, J210 and some D, K & R-class machines. It's also
  1085. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  1086. Say Y here if you have one of these machines or cards.
  1087. config SCSI_NCR_Q720
  1088. tristate "NCR Quad 720 MCA SCSI support"
  1089. depends on MCA && SCSI
  1090. select SCSI_SPI_ATTRS
  1091. help
  1092. This is a driver for the MicroChannel Quad 720 card produced by
  1093. NCR and commonly used in 345x/35xx/4100 class machines. It always
  1094. tries to negotiate sync and uses tag command queueing.
  1095. Unless you have an NCR manufactured machine, the chances are that
  1096. you do not have this SCSI card, so say N.
  1097. config SCSI_NCR53C8XX_DEFAULT_TAGS
  1098. int "default tagged command queue depth"
  1099. depends on SCSI_ZALON || SCSI_NCR_Q720
  1100. default "8"
  1101. ---help---
  1102. "Tagged command queuing" is a feature of SCSI-2 which improves
  1103. performance: the host adapter can send several SCSI commands to a
  1104. device's queue even if previous commands haven't finished yet.
  1105. Because the device is intelligent, it can optimize its operations
  1106. (like head positioning) based on its own request queue. Some SCSI
  1107. devices don't implement this properly; if you want to disable this
  1108. feature, enter 0 or 1 here (it doesn't matter which).
  1109. The default value is 8 and should be supported by most hard disks.
  1110. This value can be overridden from the boot command line using the
  1111. 'tags' option as follows (example):
  1112. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  1113. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  1114. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  1115. The normal answer therefore is to go with the default 8 and to use
  1116. a boot command line option for devices that need to use a different
  1117. command queue depth.
  1118. There is no safe option other than using good SCSI devices.
  1119. config SCSI_NCR53C8XX_MAX_TAGS
  1120. int "maximum number of queued commands"
  1121. depends on SCSI_ZALON || SCSI_NCR_Q720
  1122. default "32"
  1123. ---help---
  1124. This option allows you to specify the maximum number of commands
  1125. that can be queued to any device, when tagged command queuing is
  1126. possible. The default value is 32. Minimum is 2, maximum is 64.
  1127. Modern hard disks are able to support 64 tags and even more, but
  1128. do not seem to be faster when more than 32 tags are being used.
  1129. So, the normal answer here is to go with the default value 32 unless
  1130. you are using very large hard disks with large cache (>= 1 MB) that
  1131. are able to take advantage of more than 32 tagged commands.
  1132. There is no safe option and the default answer is recommended.
  1133. config SCSI_NCR53C8XX_SYNC
  1134. int "synchronous transfers frequency in MHz"
  1135. depends on SCSI_ZALON || SCSI_NCR_Q720
  1136. default "20"
  1137. ---help---
  1138. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  1139. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  1140. are respectively the maximum data transfer rates in mega-transfers
  1141. per second for each class. For example, a FAST-20 Wide 16 device is
  1142. able to transfer data at 20 million 16 bit packets per second for a
  1143. total rate of 40 MB/s.
  1144. You may specify 0 if you want to only use asynchronous data
  1145. transfers. This is the safest and slowest option. Otherwise, specify
  1146. a value between 5 and 80, depending on the capability of your SCSI
  1147. controller. The higher the number, the faster the data transfer.
  1148. Note that 80 should normally be ok since the driver decreases the
  1149. value automatically according to the controller's capabilities.
  1150. Your answer to this question is ignored for controllers with NVRAM,
  1151. since the driver will get this information from the user set-up. It
  1152. also can be overridden using a boot setup option, as follows
  1153. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  1154. for FAST-20 synchronous data transfer (20 mega-transfers per
  1155. second).
  1156. The normal answer therefore is not to go with the default but to
  1157. select the maximum value 80 allowing the driver to use the maximum
  1158. value supported by each controller. If this causes problems with
  1159. your SCSI devices, you should come back and decrease the value.
  1160. There is no safe option other than using good cabling, right
  1161. terminations and SCSI conformant devices.
  1162. config SCSI_NCR53C8XX_NO_DISCONNECT
  1163. bool "not allow targets to disconnect"
  1164. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  1165. help
  1166. This option is only provided for safety if you suspect some SCSI
  1167. device of yours to not support properly the target-disconnect
  1168. feature. In that case, you would say Y here. In general however, to
  1169. not allow targets to disconnect is not reasonable if there is more
  1170. than 1 device on a SCSI bus. The normal answer therefore is N.
  1171. config SCSI_PAS16
  1172. tristate "PAS16 SCSI support"
  1173. depends on ISA && SCSI
  1174. select SCSI_SPI_ATTRS
  1175. ---help---
  1176. This is support for a SCSI host adapter. It is explained in section
  1177. 3.10 of the SCSI-HOWTO, available from
  1178. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1179. of the box, you may have to change some settings in
  1180. <file:drivers/scsi/pas16.h>.
  1181. To compile this driver as a module, choose M here: the
  1182. module will be called pas16.
  1183. config SCSI_QLOGIC_FAS
  1184. tristate "Qlogic FAS SCSI support"
  1185. depends on ISA && SCSI
  1186. ---help---
  1187. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1188. FastSCSI! cards as well as any other card based on the FASXX chip
  1189. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1190. This driver does NOT support the PCI versions of these cards. The
  1191. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1192. SCSI support"), below.
  1193. Information about this driver is contained in
  1194. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1195. SCSI-HOWTO, available from
  1196. <http://www.tldp.org/docs.html#howto>.
  1197. To compile this driver as a module, choose M here: the
  1198. module will be called qlogicfas.
  1199. config SCSI_QLOGIC_1280
  1200. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1201. depends on PCI && SCSI
  1202. help
  1203. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1204. To compile this driver as a module, choose M here: the
  1205. module will be called qla1280.
  1206. config SCSI_QLOGICPTI
  1207. tristate "PTI Qlogic, ISP Driver"
  1208. depends on SBUS && SCSI
  1209. help
  1210. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1211. controllers are known under Solaris as qpti and in the openprom as
  1212. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1213. driven by a different driver.
  1214. To compile this driver as a module, choose M here: the
  1215. module will be called qlogicpti.
  1216. source "drivers/scsi/qla2xxx/Kconfig"
  1217. source "drivers/scsi/qla4xxx/Kconfig"
  1218. config SCSI_LPFC
  1219. tristate "Emulex LightPulse Fibre Channel Support"
  1220. depends on PCI && SCSI
  1221. select SCSI_FC_ATTRS
  1222. help
  1223. This lpfc driver supports the Emulex LightPulse
  1224. Family of Fibre Channel PCI host adapters.
  1225. config SCSI_LPFC_DEBUG_FS
  1226. bool "Emulex LightPulse Fibre Channel debugfs Support"
  1227. depends on SCSI_LPFC && DEBUG_FS
  1228. help
  1229. This makes debugging information from the lpfc driver
  1230. available via the debugfs filesystem.
  1231. config SCSI_SIM710
  1232. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1233. depends on (EISA || MCA) && SCSI
  1234. select SCSI_SPI_ATTRS
  1235. ---help---
  1236. This driver is for NCR53c710 based SCSI host adapters.
  1237. It currently supports Compaq EISA cards and NCR MCA cards
  1238. config SCSI_SYM53C416
  1239. tristate "Symbios 53c416 SCSI support"
  1240. depends on ISA && SCSI
  1241. ---help---
  1242. This is support for the sym53c416 SCSI host adapter, the SCSI
  1243. adapter that comes with some HP scanners. This driver requires that
  1244. the sym53c416 is configured first using some sort of PnP
  1245. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1246. are using isapnp then you need to compile this driver as a module
  1247. and then load it using insmod after isapnp has run. The parameters
  1248. of the configured card(s) should be passed to the driver. The format
  1249. is:
  1250. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1251. To compile this driver as a module, choose M here: the
  1252. module will be called sym53c416.
  1253. config SCSI_DC395x
  1254. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1255. depends on PCI && SCSI && EXPERIMENTAL
  1256. ---help---
  1257. This driver supports PCI SCSI host adapters based on the ASIC
  1258. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1259. This driver works, but is still in experimental status. So better
  1260. have a bootable disk and a backup in case of emergency.
  1261. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1262. To compile this driver as a module, choose M here: the
  1263. module will be called dc395x.
  1264. config SCSI_DC390T
  1265. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1266. depends on PCI && SCSI
  1267. ---help---
  1268. This driver supports PCI SCSI host adapters based on the Am53C974A
  1269. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1270. PCscsi/PCnet (Am53/79C974) solutions.
  1271. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1272. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1273. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1274. To compile this driver as a module, choose M here: the
  1275. module will be called tmscsim.
  1276. config SCSI_T128
  1277. tristate "Trantor T128/T128F/T228 SCSI support"
  1278. depends on ISA && SCSI
  1279. select SCSI_SPI_ATTRS
  1280. select CHECK_SIGNATURE
  1281. ---help---
  1282. This is support for a SCSI host adapter. It is explained in section
  1283. 3.11 of the SCSI-HOWTO, available from
  1284. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1285. of the box, you may have to change some settings in
  1286. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1287. Adaptec, and some former Trantor products are being sold under the
  1288. Adaptec name.
  1289. To compile this driver as a module, choose M here: the
  1290. module will be called t128.
  1291. config SCSI_U14_34F
  1292. tristate "UltraStor 14F/34F support"
  1293. depends on ISA && SCSI && ISA_DMA_API
  1294. ---help---
  1295. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1296. The source at <file:drivers/scsi/u14-34f.c> contains some
  1297. information about this hardware. If the driver doesn't work out of
  1298. the box, you may have to change some settings in
  1299. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1300. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1301. another driver for the same hardware: "UltraStor SCSI support",
  1302. below. You should say Y to both only if you want 24F support as
  1303. well.
  1304. To compile this driver as a module, choose M here: the
  1305. module will be called u14-34f.
  1306. config SCSI_U14_34F_TAGGED_QUEUE
  1307. bool "enable tagged command queueing"
  1308. depends on SCSI_U14_34F
  1309. help
  1310. This is a feature of SCSI-2 which improves performance: the host
  1311. adapter can send several SCSI commands to a device's queue even if
  1312. previous commands haven't finished yet.
  1313. This is equivalent to the "u14-34f=tc:y" boot option.
  1314. config SCSI_U14_34F_LINKED_COMMANDS
  1315. bool "enable elevator sorting"
  1316. depends on SCSI_U14_34F
  1317. help
  1318. This option enables elevator sorting for all probed SCSI disks and
  1319. CD-ROMs. It definitely reduces the average seek distance when doing
  1320. random seeks, but this does not necessarily result in a noticeable
  1321. performance improvement: your mileage may vary...
  1322. This is equivalent to the "u14-34f=lc:y" boot option.
  1323. config SCSI_U14_34F_MAX_TAGS
  1324. int "maximum number of queued commands"
  1325. depends on SCSI_U14_34F
  1326. default "8"
  1327. help
  1328. This specifies how many SCSI commands can be maximally queued for
  1329. each probed SCSI device. You should reduce the default value of 8
  1330. only if you have disks with buggy or limited tagged command support.
  1331. Minimum is 2 and maximum is 14. This value is also the window size
  1332. used by the elevator sorting option above. The effective value used
  1333. by the driver for each probed SCSI device is reported at boot time.
  1334. This is equivalent to the "u14-34f=mq:8" boot option.
  1335. config SCSI_ULTRASTOR
  1336. tristate "UltraStor SCSI support"
  1337. depends on X86 && ISA && SCSI
  1338. ---help---
  1339. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1340. adapter family. This driver is explained in section 3.12 of the
  1341. SCSI-HOWTO, available from
  1342. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1343. of the box, you may have to change some settings in
  1344. <file:drivers/scsi/ultrastor.h>.
  1345. Note that there is also another driver for the same hardware:
  1346. "UltraStor 14F/34F support", above.
  1347. To compile this driver as a module, choose M here: the
  1348. module will be called ultrastor.
  1349. config SCSI_NSP32
  1350. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1351. depends on PCI && SCSI && !64BIT
  1352. help
  1353. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1354. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1355. <http://www.tldp.org/docs.html#howto>.
  1356. To compile this driver as a module, choose M here: the
  1357. module will be called nsp32.
  1358. config SCSI_DEBUG
  1359. tristate "SCSI debugging host simulator"
  1360. depends on SCSI
  1361. select CRC_T10DIF
  1362. help
  1363. This is a host adapter simulator that can simulate multiple hosts
  1364. each with multiple dummy SCSI devices (disks). It defaults to one
  1365. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1366. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1367. dummy disks are simulated, they share the same kernel RAM for
  1368. their storage. See <http://sg.danny.cz/sg/sdebug26.html> for more
  1369. information. This driver is primarily of use to those testing the
  1370. SCSI and block subsystems. If unsure, say N.
  1371. config SCSI_MESH
  1372. tristate "MESH (Power Mac internal SCSI) support"
  1373. depends on PPC32 && PPC_PMAC && SCSI
  1374. help
  1375. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1376. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1377. other Power Macintoshes do). Say Y to include support for this SCSI
  1378. adaptor.
  1379. To compile this driver as a module, choose M here: the
  1380. module will be called mesh.
  1381. config SCSI_MESH_SYNC_RATE
  1382. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1383. depends on SCSI_MESH
  1384. default "5"
  1385. help
  1386. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1387. drives a bus which is entirely internal to the machine (such as the
  1388. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1389. operation at up to 10 MB/s. On machines where the SCSI bus
  1390. controlled by the MESH can have external devices connected, it is
  1391. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1392. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1393. to disable synchronous operation.
  1394. config SCSI_MESH_RESET_DELAY_MS
  1395. int "initial bus reset delay (ms) (0 = no reset)"
  1396. depends on SCSI_MESH
  1397. default "4000"
  1398. config SCSI_MAC53C94
  1399. tristate "53C94 (Power Mac external SCSI) support"
  1400. depends on PPC32 && PPC_PMAC && SCSI
  1401. help
  1402. On Power Macintoshes (and clones) with two SCSI buses, the external
  1403. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1404. machines which only have one SCSI bus, such as the 7200, also use
  1405. the 53C94. Say Y to include support for the 53C94.
  1406. To compile this driver as a module, choose M here: the
  1407. module will be called mac53c94.
  1408. source "drivers/scsi/arm/Kconfig"
  1409. config JAZZ_ESP
  1410. bool "MIPS JAZZ FAS216 SCSI support"
  1411. depends on MACH_JAZZ && SCSI
  1412. select SCSI_SPI_ATTRS
  1413. help
  1414. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1415. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1416. systems.
  1417. config A3000_SCSI
  1418. tristate "A3000 WD33C93A support"
  1419. depends on AMIGA && SCSI
  1420. help
  1421. If you have an Amiga 3000 and have SCSI devices connected to the
  1422. built-in SCSI controller, say Y. Otherwise, say N.
  1423. To compile this driver as a module, choose M here: the
  1424. module will be called a3000.
  1425. config A2091_SCSI
  1426. tristate "A2091/A590 WD33C93A support"
  1427. depends on ZORRO && SCSI
  1428. help
  1429. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1430. say N.
  1431. To compile this driver as a module, choose M here: the
  1432. module will be called a2091.
  1433. config GVP11_SCSI
  1434. tristate "GVP Series II WD33C93A support"
  1435. depends on ZORRO && SCSI
  1436. ---help---
  1437. If you have a Great Valley Products Series II SCSI controller,
  1438. answer Y. Also say Y if you have a later model of GVP SCSI
  1439. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1440. answer N. This driver does NOT work for the T-Rex series of
  1441. accelerators from TekMagic and GVP-M.
  1442. To compile this driver as a module, choose M here: the
  1443. module will be called gvp11.
  1444. config SCSI_A4000T
  1445. tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
  1446. depends on AMIGA && SCSI && EXPERIMENTAL
  1447. select SCSI_SPI_ATTRS
  1448. help
  1449. If you have an Amiga 4000T and have SCSI devices connected to the
  1450. built-in SCSI controller, say Y. Otherwise, say N.
  1451. To compile this driver as a module, choose M here: the
  1452. module will be called a4000t.
  1453. config SCSI_ZORRO7XX
  1454. tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
  1455. depends on ZORRO && SCSI && EXPERIMENTAL
  1456. select SCSI_SPI_ATTRS
  1457. help
  1458. Support for various NCR53c710-based SCSI controllers on Zorro
  1459. expansion boards for the Amiga.
  1460. This includes:
  1461. - the Amiga 4091 Zorro III SCSI-2 controller,
  1462. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1463. (info at
  1464. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1465. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1466. accelerator card for the Amiga 1200,
  1467. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1468. config ATARI_SCSI
  1469. tristate "Atari native SCSI support"
  1470. depends on ATARI && SCSI
  1471. select SCSI_SPI_ATTRS
  1472. select NVRAM
  1473. ---help---
  1474. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1475. Falcon, ...) say Y to get it supported. Of course also, if you have
  1476. a compatible SCSI controller (e.g. for Medusa).
  1477. To compile this driver as a module, choose M here: the
  1478. module will be called atari_scsi.
  1479. This driver supports both styles of NCR integration into the
  1480. system: the TT style (separate DMA), and the Falcon style (via
  1481. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1482. in the Hades (without DMA).
  1483. config ATARI_SCSI_TOSHIBA_DELAY
  1484. bool "Long delays for Toshiba CD-ROMs"
  1485. depends on ATARI_SCSI
  1486. help
  1487. This option increases the delay after a SCSI arbitration to
  1488. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1489. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1490. would impact performance a bit, so say N.
  1491. config ATARI_SCSI_RESET_BOOT
  1492. bool "Reset SCSI-devices at boottime"
  1493. depends on ATARI_SCSI
  1494. help
  1495. Reset the devices on your Atari whenever it boots. This makes the
  1496. boot process fractionally longer but may assist recovery from errors
  1497. that leave the devices with SCSI operations partway completed.
  1498. config MAC_SCSI
  1499. bool "Macintosh NCR5380 SCSI"
  1500. depends on MAC && SCSI=y
  1501. select SCSI_SPI_ATTRS
  1502. help
  1503. This is the NCR 5380 SCSI controller included on most of the 68030
  1504. based Macintoshes. If you have one of these say Y and read the
  1505. SCSI-HOWTO, available from
  1506. <http://www.tldp.org/docs.html#howto>.
  1507. config SCSI_MAC_ESP
  1508. tristate "Macintosh NCR53c9[46] SCSI"
  1509. depends on MAC && SCSI
  1510. select SCSI_SPI_ATTRS
  1511. help
  1512. This is the NCR 53c9x SCSI controller found on most of the 68040
  1513. based Macintoshes.
  1514. To compile this driver as a module, choose M here: the module
  1515. will be called mac_esp.
  1516. config MVME147_SCSI
  1517. bool "WD33C93 SCSI driver for MVME147"
  1518. depends on MVME147 && SCSI=y
  1519. select SCSI_SPI_ATTRS
  1520. help
  1521. Support for the on-board SCSI controller on the Motorola MVME147
  1522. single-board computer.
  1523. config MVME16x_SCSI
  1524. tristate "NCR53C710 SCSI driver for MVME16x"
  1525. depends on MVME16x && SCSI
  1526. select SCSI_SPI_ATTRS
  1527. help
  1528. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1529. SCSI controller chip. Almost everyone using one of these boards
  1530. will want to say Y to this question.
  1531. config BVME6000_SCSI
  1532. tristate "NCR53C710 SCSI driver for BVME6000"
  1533. depends on BVME6000 && SCSI
  1534. select SCSI_SPI_ATTRS
  1535. help
  1536. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1537. SCSI controller chip. Almost everyone using one of these boards
  1538. will want to say Y to this question.
  1539. config SUN3_SCSI
  1540. tristate "Sun3 NCR5380 SCSI"
  1541. depends on SUN3 && SCSI
  1542. select SCSI_SPI_ATTRS
  1543. help
  1544. This option will enable support for the OBIO (onboard io) NCR5380
  1545. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1546. "Sun3" type VME scsi controllers also based on the NCR5380.
  1547. General Linux information on the Sun 3 series (now discontinued)
  1548. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1549. config SUN3X_ESP
  1550. bool "Sun3x ESP SCSI"
  1551. depends on SUN3X && SCSI=y
  1552. select SCSI_SPI_ATTRS
  1553. help
  1554. The ESP was an on-board SCSI controller used on Sun 3/80
  1555. machines. Say Y here to compile in support for it.
  1556. config SCSI_SUNESP
  1557. tristate "Sparc ESP Scsi Driver"
  1558. depends on SBUS && SCSI
  1559. select SCSI_SPI_ATTRS
  1560. help
  1561. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1562. chipset is present in most SPARC SBUS-based computers and
  1563. supports the Emulex family of ESP SCSI chips (esp100, esp100A,
  1564. esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
  1565. To compile this driver as a module, choose M here: the
  1566. module will be called sun_esp.
  1567. config ZFCP
  1568. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1569. depends on S390 && QDIO && SCSI
  1570. select SCSI_FC_ATTRS
  1571. help
  1572. If you want to access SCSI devices attached to your IBM eServer
  1573. zSeries by means of Fibre Channel interfaces say Y.
  1574. For details please refer to the documentation provided by IBM at
  1575. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1576. This driver is also available as a module. This module will be
  1577. called zfcp. If you want to compile it as a module, say M here
  1578. and read <file:Documentation/kbuild/modules.txt>.
  1579. config SCSI_PMCRAID
  1580. tristate "PMC SIERRA Linux MaxRAID adapter support"
  1581. depends on PCI && SCSI && NET
  1582. ---help---
  1583. This driver supports the PMC SIERRA MaxRAID adapters.
  1584. config SCSI_PM8001
  1585. tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
  1586. depends on PCI && SCSI
  1587. select SCSI_SAS_LIBSAS
  1588. help
  1589. This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
  1590. based host adapters.
  1591. config SCSI_SRP
  1592. tristate "SCSI RDMA Protocol helper library"
  1593. depends on SCSI && PCI
  1594. select SCSI_TGT
  1595. help
  1596. If you wish to use SRP target drivers, say Y.
  1597. To compile this driver as a module, choose M here: the
  1598. module will be called libsrp.
  1599. config SCSI_BFA_FC
  1600. tristate "Brocade BFA Fibre Channel Support"
  1601. depends on PCI && SCSI
  1602. select SCSI_FC_ATTRS
  1603. help
  1604. This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
  1605. To compile this driver as a module, choose M here. The module will
  1606. be called bfa.
  1607. endif # SCSI_LOWLEVEL
  1608. source "drivers/scsi/pcmcia/Kconfig"
  1609. source "drivers/scsi/device_handler/Kconfig"
  1610. source "drivers/scsi/osd/Kconfig"
  1611. endmenu