Kconfig 66 KB

1234567891011121314151617181920212223242526272829303132333435363738394041424344454647484950515253545556575859606162636465666768697071727374757677787980818283848586878889909192939495969798991001011021031041051061071081091101111121131141151161171181191201211221231241251261271281291301311321331341351361371381391401411421431441451461471481491501511521531541551561571581591601611621631641651661671681691701711721731741751761771781791801811821831841851861871881891901911921931941951961971981992002012022032042052062072082092102112122132142152162172182192202212222232242252262272282292302312322332342352362372382392402412422432442452462472482492502512522532542552562572582592602612622632642652662672682692702712722732742752762772782792802812822832842852862872882892902912922932942952962972982993003013023033043053063073083093103113123133143153163173183193203213223233243253263273283293303313323333343353363373383393403413423433443453463473483493503513523533543553563573583593603613623633643653663673683693703713723733743753763773783793803813823833843853863873883893903913923933943953963973983994004014024034044054064074084094104114124134144154164174184194204214224234244254264274284294304314324334344354364374384394404414424434444454464474484494504514524534544554564574584594604614624634644654664674684694704714724734744754764774784794804814824834844854864874884894904914924934944954964974984995005015025035045055065075085095105115125135145155165175185195205215225235245255265275285295305315325335345355365375385395405415425435445455465475485495505515525535545555565575585595605615625635645655665675685695705715725735745755765775785795805815825835845855865875885895905915925935945955965975985996006016026036046056066076086096106116126136146156166176186196206216226236246256266276286296306316326336346356366376386396406416426436446456466476486496506516526536546556566576586596606616626636646656666676686696706716726736746756766776786796806816826836846856866876886896906916926936946956966976986997007017027037047057067077087097107117127137147157167177187197207217227237247257267277287297307317327337347357367377387397407417427437447457467477487497507517527537547557567577587597607617627637647657667677687697707717727737747757767777787797807817827837847857867877887897907917927937947957967977987998008018028038048058068078088098108118128138148158168178188198208218228238248258268278288298308318328338348358368378388398408418428438448458468478488498508518528538548558568578588598608618628638648658668678688698708718728738748758768778788798808818828838848858868878888898908918928938948958968978988999009019029039049059069079089099109119129139149159169179189199209219229239249259269279289299309319329339349359369379389399409419429439449459469479489499509519529539549559569579589599609619629639649659669679689699709719729739749759769779789799809819829839849859869879889899909919929939949959969979989991000100110021003100410051006100710081009101010111012101310141015101610171018101910201021102210231024102510261027102810291030103110321033103410351036103710381039104010411042104310441045104610471048104910501051105210531054105510561057105810591060106110621063106410651066106710681069107010711072107310741075107610771078107910801081108210831084108510861087108810891090109110921093109410951096109710981099110011011102110311041105110611071108110911101111111211131114111511161117111811191120112111221123112411251126112711281129113011311132113311341135113611371138113911401141114211431144114511461147114811491150115111521153115411551156115711581159116011611162116311641165116611671168116911701171117211731174117511761177117811791180118111821183118411851186118711881189119011911192119311941195119611971198119912001201120212031204120512061207120812091210121112121213121412151216121712181219122012211222122312241225122612271228122912301231123212331234123512361237123812391240124112421243124412451246124712481249125012511252125312541255125612571258125912601261126212631264126512661267126812691270127112721273127412751276127712781279128012811282128312841285128612871288128912901291129212931294129512961297129812991300130113021303130413051306130713081309131013111312131313141315131613171318131913201321132213231324132513261327132813291330133113321333133413351336133713381339134013411342134313441345134613471348134913501351135213531354135513561357135813591360136113621363136413651366136713681369137013711372137313741375137613771378137913801381138213831384138513861387138813891390139113921393139413951396139713981399140014011402140314041405140614071408140914101411141214131414141514161417141814191420142114221423142414251426142714281429143014311432143314341435143614371438143914401441144214431444144514461447144814491450145114521453145414551456145714581459146014611462146314641465146614671468146914701471147214731474147514761477147814791480148114821483148414851486148714881489149014911492149314941495149614971498149915001501150215031504150515061507150815091510151115121513151415151516151715181519152015211522152315241525152615271528152915301531153215331534153515361537153815391540154115421543154415451546154715481549155015511552155315541555155615571558155915601561156215631564156515661567156815691570157115721573157415751576157715781579158015811582158315841585158615871588158915901591159215931594159515961597159815991600160116021603160416051606160716081609161016111612161316141615161616171618161916201621162216231624162516261627162816291630163116321633163416351636163716381639164016411642164316441645164616471648164916501651165216531654165516561657165816591660166116621663166416651666166716681669167016711672167316741675167616771678167916801681168216831684168516861687168816891690169116921693169416951696169716981699170017011702170317041705170617071708170917101711171217131714171517161717171817191720172117221723172417251726172717281729173017311732173317341735173617371738173917401741174217431744174517461747174817491750175117521753175417551756175717581759176017611762176317641765176617671768176917701771177217731774177517761777177817791780178117821783178417851786178717881789179017911792179317941795179617971798179918001801180218031804180518061807180818091810181118121813181418151816181718181819182018211822182318241825182618271828182918301831183218331834
  1. menu "SCSI device support"
  2. config RAID_ATTRS
  3. tristate "RAID Transport Class"
  4. default n
  5. ---help---
  6. Provides RAID
  7. config SCSI
  8. tristate "SCSI device support"
  9. ---help---
  10. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  11. any other SCSI device under Linux, say Y and make sure that you know
  12. the name of your SCSI host adapter (the card inside your computer
  13. that "speaks" the SCSI protocol, also called SCSI controller),
  14. because you will be asked for it.
  15. You also need to say Y here if you have a device which speaks
  16. the SCSI protocol. Examples of this include the parallel port
  17. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  18. Channel, FireWire storage and the IDE-SCSI emulation driver.
  19. To compile this driver as a module, choose M here and read
  20. <file:Documentation/scsi/scsi.txt>.
  21. The module will be called scsi_mod.
  22. However, do not compile this as a module if your root file system
  23. (the one containing the directory /) is located on a SCSI device.
  24. config SCSI_PROC_FS
  25. bool "legacy /proc/scsi/ support"
  26. depends on SCSI && PROC_FS
  27. default y
  28. ---help---
  29. This option enables support for the various files in
  30. /proc/scsi. In Linux 2.6 this has been superceeded by
  31. files in sysfs but many legacy applications rely on this.
  32. If unusure say Y.
  33. comment "SCSI support type (disk, tape, CD-ROM)"
  34. depends on SCSI
  35. config BLK_DEV_SD
  36. tristate "SCSI disk support"
  37. depends on SCSI
  38. ---help---
  39. If you want to use SCSI hard disks, Fibre Channel disks,
  40. USB storage or the SCSI or parallel port version of
  41. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  42. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  43. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  44. CD-ROMs.
  45. To compile this driver as a module, choose M here and read
  46. <file:Documentation/scsi/scsi.txt>.
  47. The module will be called sd_mod.
  48. Do not compile this driver as a module if your root file system
  49. (the one containing the directory /) is located on a SCSI disk.
  50. In this case, do not compile the driver for your SCSI host adapter
  51. (below) as a module either.
  52. config CHR_DEV_ST
  53. tristate "SCSI tape support"
  54. depends on SCSI
  55. ---help---
  56. If you want to use a SCSI tape drive under Linux, say Y and read the
  57. SCSI-HOWTO, available from
  58. <http://www.tldp.org/docs.html#howto>, and
  59. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  60. for SCSI CD-ROMs.
  61. To compile this driver as a module, choose M here and read
  62. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  63. config CHR_DEV_OSST
  64. tristate "SCSI OnStream SC-x0 tape support"
  65. depends on SCSI
  66. ---help---
  67. The OnStream SC-x0 SCSI tape drives can not be driven by the
  68. standard st driver, but instead need this special osst driver and
  69. use the /dev/osstX char device nodes (major 206). Via usb-storage
  70. and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
  71. as well. Note that there is also a second generation of OnStream
  72. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  73. tapes (QIC-157) and can be driven by the standard driver st.
  74. For more information, you may have a look at the SCSI-HOWTO
  75. <http://www.tldp.org/docs.html#howto> and
  76. <file:Documentation/scsi/osst.txt> in the kernel source.
  77. More info on the OnStream driver may be found on
  78. <http://linux1.onstream.nl/test/>
  79. Please also have a look at the standard st docu, as most of it
  80. applies to osst as well.
  81. To compile this driver as a module, choose M here and read
  82. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  83. config BLK_DEV_SR
  84. tristate "SCSI CDROM support"
  85. depends on SCSI
  86. ---help---
  87. If you want to use a SCSI or FireWire CD-ROM under Linux,
  88. say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
  89. <http://www.tldp.org/docs.html#howto>. Also make sure to say
  90. Y or M to "ISO 9660 CD-ROM file system support" later.
  91. To compile this driver as a module, choose M here and read
  92. <file:Documentation/scsi/scsi.txt>.
  93. The module will be called sr_mod.
  94. config BLK_DEV_SR_VENDOR
  95. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  96. depends on BLK_DEV_SR
  97. help
  98. This enables the usage of vendor specific SCSI commands. This is
  99. required to support multisession CDs with old NEC/TOSHIBA cdrom
  100. drives (and HP Writers). If you have such a drive and get the first
  101. session only, try saying Y here; everybody else says N.
  102. config CHR_DEV_SG
  103. tristate "SCSI generic support"
  104. depends on SCSI
  105. ---help---
  106. If you want to use SCSI scanners, synthesizers or CD-writers or just
  107. about anything having "SCSI" in its name other than hard disks,
  108. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  109. directly, so you need some additional software which knows how to
  110. talk to these devices using the SCSI protocol:
  111. For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
  112. writer software look at Cdrtools
  113. (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
  114. and for burning a "disk at once": CDRDAO
  115. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  116. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  117. For other devices, it's possible that you'll have to write the
  118. driver software yourself. Please read the file
  119. <file:Documentation/scsi/scsi-generic.txt> for more information.
  120. To compile this driver as a module, choose M here and read
  121. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  122. If unsure, say N.
  123. config CHR_DEV_SCH
  124. tristate "SCSI media changer support"
  125. depends on SCSI
  126. ---help---
  127. This is a driver for SCSI media changers. Most common devices are
  128. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  129. don't need this for those tiny 6-slot cdrom changers. Media
  130. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  131. If you have such hardware and want to use it with linux, say Y
  132. here. Check <file:Documentation/scsi-changer.txt> for details.
  133. If you want to compile this as a module ( = code which can be
  134. inserted in and removed from the running kernel whenever you want),
  135. say M here and read <file:Documentation/modules.txt> and
  136. <file:Documentation/scsi.txt>. The module will be called ch.o.
  137. If unsure, say N.
  138. comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
  139. depends on SCSI
  140. config SCSI_MULTI_LUN
  141. bool "Probe all LUNs on each SCSI device"
  142. depends on SCSI
  143. help
  144. If you have a SCSI device that supports more than one LUN (Logical
  145. Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
  146. can say Y here to force the SCSI driver to probe for multiple LUNs.
  147. A SCSI device with multiple LUNs acts logically like multiple SCSI
  148. devices. The vast majority of SCSI devices have only one LUN, and
  149. so most people can say N here. The max_luns boot/module parameter
  150. allows to override this setting.
  151. config SCSI_CONSTANTS
  152. bool "Verbose SCSI error reporting (kernel size +=12K)"
  153. depends on SCSI
  154. help
  155. The error messages regarding your SCSI hardware will be easier to
  156. understand if you say Y here; it will enlarge your kernel by about
  157. 12 KB. If in doubt, say Y.
  158. config SCSI_LOGGING
  159. bool "SCSI logging facility"
  160. depends on SCSI
  161. ---help---
  162. This turns on a logging facility that can be used to debug a number
  163. of SCSI related problems.
  164. If you say Y here, no logging output will appear by default, but you
  165. can enable logging by saying Y to "/proc file system support" and
  166. "Sysctl support" below and executing the command
  167. echo "scsi log token [level]" > /proc/scsi/scsi
  168. at boot time after the /proc file system has been mounted.
  169. There are a number of things that can be used for 'token' (you can
  170. find them in the source: <file:drivers/scsi/scsi.c>), and this
  171. allows you to select the types of information you want, and the
  172. level allows you to select the level of verbosity.
  173. If you say N here, it may be harder to track down some types of SCSI
  174. problems. If you say Y here your kernel will be somewhat larger, but
  175. there should be no noticeable performance impact as long as you have
  176. logging turned off.
  177. menu "SCSI Transport Attributes"
  178. depends on SCSI
  179. config SCSI_SPI_ATTRS
  180. tristate "Parallel SCSI (SPI) Transport Attributes"
  181. depends on SCSI
  182. help
  183. If you wish to export transport-specific information about
  184. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  185. config SCSI_FC_ATTRS
  186. tristate "FiberChannel Transport Attributes"
  187. depends on SCSI
  188. help
  189. If you wish to export transport-specific information about
  190. each attached FiberChannel device to sysfs, say Y.
  191. Otherwise, say N.
  192. config SCSI_ISCSI_ATTRS
  193. tristate "iSCSI Transport Attributes"
  194. depends on SCSI && NET
  195. help
  196. If you wish to export transport-specific information about
  197. each attached iSCSI device to sysfs, say Y.
  198. Otherwise, say N.
  199. config SCSI_SAS_ATTRS
  200. tristate "SAS Transport Attributes"
  201. depends on SCSI
  202. help
  203. If you wish to export transport-specific information about
  204. each attached SAS device to sysfs, say Y.
  205. endmenu
  206. menu "SCSI low-level drivers"
  207. depends on SCSI!=n
  208. config ISCSI_TCP
  209. tristate "iSCSI Initiator over TCP/IP"
  210. depends on SCSI && INET
  211. select CRYPTO
  212. select CRYPTO_MD5
  213. select CRYPTO_CRC32C
  214. select SCSI_ISCSI_ATTRS
  215. help
  216. The iSCSI Driver provides a host with the ability to access storage
  217. through an IP network. The driver uses the iSCSI protocol to transport
  218. SCSI requests and responses over a TCP/IP network between the host
  219. (the "initiator") and "targets". Architecturally, the iSCSI driver
  220. combines with the host's TCP/IP stack, network drivers, and Network
  221. Interface Card (NIC) to provide the same functions as a SCSI or a
  222. Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
  223. To compile this driver as a module, choose M here: the
  224. module will be called iscsi_tcp.
  225. The userspace component needed to initialize the driver, documentation,
  226. and sample configuration files can be found here:
  227. http://linux-iscsi.sf.net
  228. config SGIWD93_SCSI
  229. tristate "SGI WD93C93 SCSI Driver"
  230. depends on SGI_IP22 && SCSI
  231. help
  232. If you have a Western Digital WD93 SCSI controller on
  233. an SGI MIPS system, say Y. Otherwise, say N.
  234. config SCSI_DECNCR
  235. tristate "DEC NCR53C94 Scsi Driver"
  236. depends on MACH_DECSTATION && SCSI && TC
  237. help
  238. Say Y here to support the NCR53C94 SCSI controller chips on IOASIC
  239. based TURBOchannel DECstations and TURBOchannel PMAZ-A cards.
  240. config SCSI_DECSII
  241. tristate "DEC SII Scsi Driver"
  242. depends on MACH_DECSTATION && SCSI && 32BIT
  243. config BLK_DEV_3W_XXXX_RAID
  244. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  245. depends on PCI && SCSI
  246. help
  247. 3ware is the only hardware ATA-Raid product in Linux to date.
  248. This card is 2,4, or 8 channel master mode support only.
  249. SCSI support required!!!
  250. <http://www.3ware.com/>
  251. Please read the comments at the top of
  252. <file:drivers/scsi/3w-xxxx.c>.
  253. config SCSI_3W_9XXX
  254. tristate "3ware 9xxx SATA-RAID support"
  255. depends on PCI && SCSI
  256. help
  257. This driver supports the 9000 series 3ware SATA-RAID cards.
  258. <http://www.amcc.com>
  259. Please read the comments at the top of
  260. <file:drivers/scsi/3w-9xxx.c>.
  261. config SCSI_7000FASST
  262. tristate "7000FASST SCSI support"
  263. depends on ISA && SCSI && ISA_DMA_API
  264. help
  265. This driver supports the Western Digital 7000 SCSI host adapter
  266. family. Some information is in the source:
  267. <file:drivers/scsi/wd7000.c>.
  268. To compile this driver as a module, choose M here: the
  269. module will be called wd7000.
  270. config SCSI_ACARD
  271. tristate "ACARD SCSI support"
  272. depends on PCI && SCSI
  273. help
  274. This driver supports the ACARD SCSI host adapter.
  275. Support Chip <ATP870 ATP876 ATP880 ATP885>
  276. To compile this driver as a module, choose M here: the
  277. module will be called atp870u.
  278. config SCSI_AHA152X
  279. tristate "Adaptec AHA152X/2825 support"
  280. depends on ISA && SCSI && !64BIT
  281. select SCSI_SPI_ATTRS
  282. ---help---
  283. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  284. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  285. must be manually specified in this case.
  286. It is explained in section 3.3 of the SCSI-HOWTO, available from
  287. <http://www.tldp.org/docs.html#howto>. You might also want to
  288. read the file <file:Documentation/scsi/aha152x.txt>.
  289. To compile this driver as a module, choose M here: the
  290. module will be called aha152x.
  291. config SCSI_AHA1542
  292. tristate "Adaptec AHA1542 support"
  293. depends on ISA && SCSI && ISA_DMA_API
  294. ---help---
  295. This is support for a SCSI host adapter. It is explained in section
  296. 3.4 of the SCSI-HOWTO, available from
  297. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  298. purchased by Adaptec, and some former Trantor products are being
  299. sold under the Adaptec name. If it doesn't work out of the box, you
  300. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  301. To compile this driver as a module, choose M here: the
  302. module will be called aha1542.
  303. config SCSI_AHA1740
  304. tristate "Adaptec AHA1740 support"
  305. depends on EISA && SCSI
  306. ---help---
  307. This is support for a SCSI host adapter. It is explained in section
  308. 3.5 of the SCSI-HOWTO, available from
  309. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  310. of the box, you may have to change some settings in
  311. <file:drivers/scsi/aha1740.h>.
  312. To compile this driver as a module, choose M here: the
  313. module will be called aha1740.
  314. config SCSI_AACRAID
  315. tristate "Adaptec AACRAID support"
  316. depends on SCSI && PCI
  317. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  318. config SCSI_AIC7XXX_OLD
  319. tristate "Adaptec AIC7xxx support (old driver)"
  320. depends on (ISA || EISA || PCI ) && SCSI
  321. help
  322. WARNING This driver is an older aic7xxx driver and is no longer
  323. under active development. Adaptec, Inc. is writing a new driver to
  324. take the place of this one, and it is recommended that whenever
  325. possible, people should use the new Adaptec written driver instead
  326. of this one. This driver will eventually be phased out entirely.
  327. This is support for the various aic7xxx based Adaptec SCSI
  328. controllers. These include the 274x EISA cards; 284x VLB cards;
  329. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  330. motherboard based SCSI controllers from Adaptec. It does not support
  331. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  332. support them. It does not support the 2920 cards from Adaptec that
  333. use the Future Domain SCSI controller chip. For those cards, you
  334. need the "Future Domain 16xx SCSI support" driver.
  335. In general, if the controller is based on an Adaptec SCSI controller
  336. chip from the aic777x series or the aic78xx series, this driver
  337. should work. The only exception is the 7810 which is specifically
  338. not supported (that's the RAID controller chip on the AAA-13x
  339. cards).
  340. Note that the AHA2920 SCSI host adapter is *not* supported by this
  341. driver; choose "Future Domain 16xx SCSI support" instead if you have
  342. one of those.
  343. Information on the configuration options for this controller can be
  344. found by checking the help file for each of the available
  345. configuration options. You should read
  346. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  347. contacting the maintainer with any questions. The SCSI-HOWTO,
  348. available from <http://www.tldp.org/docs.html#howto>, can also
  349. be of great help.
  350. To compile this driver as a module, choose M here: the
  351. module will be called aic7xxx_old.
  352. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  353. # All the I2O code and drivers do not seem to be 64bit safe.
  354. config SCSI_DPT_I2O
  355. tristate "Adaptec I2O RAID support "
  356. depends on !64BIT && SCSI && PCI
  357. help
  358. This driver supports all of Adaptec's I2O based RAID controllers as
  359. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  360. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  361. To compile this driver as a module, choose M here: the
  362. module will be called dpt_i2o.
  363. config SCSI_ADVANSYS
  364. tristate "AdvanSys SCSI support"
  365. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  366. help
  367. This is a driver for all SCSI host adapters manufactured by
  368. AdvanSys. It is documented in the kernel source in
  369. <file:drivers/scsi/advansys.c>.
  370. To compile this driver as a module, choose M here: the
  371. module will be called advansys.
  372. config SCSI_IN2000
  373. tristate "Always IN2000 SCSI support"
  374. depends on ISA && SCSI
  375. help
  376. This is support for an ISA bus SCSI host adapter. You'll find more
  377. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  378. out of the box, you may have to change the jumpers for IRQ or
  379. address selection.
  380. To compile this driver as a module, choose M here: the
  381. module will be called in2000.
  382. source "drivers/scsi/megaraid/Kconfig.megaraid"
  383. config SCSI_SATA
  384. tristate "Serial ATA (SATA) support"
  385. depends on SCSI
  386. help
  387. This driver family supports Serial ATA host controllers
  388. and devices.
  389. If unsure, say N.
  390. config SCSI_SATA_AHCI
  391. tristate "AHCI SATA support"
  392. depends on SCSI_SATA && PCI
  393. help
  394. This option enables support for AHCI Serial ATA.
  395. If unsure, say N.
  396. config SCSI_SATA_SVW
  397. tristate "ServerWorks Frodo / Apple K2 SATA support"
  398. depends on SCSI_SATA && PCI
  399. help
  400. This option enables support for Broadcom/Serverworks/Apple K2
  401. SATA support.
  402. If unsure, say N.
  403. config SCSI_ATA_PIIX
  404. tristate "Intel PIIX/ICH SATA support"
  405. depends on SCSI_SATA && PCI
  406. help
  407. This option enables support for ICH5 Serial ATA.
  408. If PATA support was enabled previously, this enables
  409. support for select Intel PIIX/ICH PATA host controllers.
  410. If unsure, say N.
  411. config SCSI_SATA_MV
  412. tristate "Marvell SATA support (HIGHLY EXPERIMENTAL)"
  413. depends on SCSI_SATA && PCI && EXPERIMENTAL
  414. help
  415. This option enables support for the Marvell Serial ATA family.
  416. Currently supports 88SX[56]0[48][01] chips.
  417. If unsure, say N.
  418. config SCSI_SATA_NV
  419. tristate "NVIDIA SATA support"
  420. depends on SCSI_SATA && PCI && EXPERIMENTAL
  421. help
  422. This option enables support for NVIDIA Serial ATA.
  423. If unsure, say N.
  424. config SCSI_PDC_ADMA
  425. tristate "Pacific Digital ADMA support"
  426. depends on SCSI_SATA && PCI
  427. help
  428. This option enables support for Pacific Digital ADMA controllers
  429. If unsure, say N.
  430. config SCSI_SATA_QSTOR
  431. tristate "Pacific Digital SATA QStor support"
  432. depends on SCSI_SATA && PCI
  433. help
  434. This option enables support for Pacific Digital Serial ATA QStor.
  435. If unsure, say N.
  436. config SCSI_SATA_PROMISE
  437. tristate "Promise SATA TX2/TX4 support"
  438. depends on SCSI_SATA && PCI
  439. help
  440. This option enables support for Promise Serial ATA TX2/TX4.
  441. If unsure, say N.
  442. config SCSI_SATA_SX4
  443. tristate "Promise SATA SX4 support"
  444. depends on SCSI_SATA && PCI && EXPERIMENTAL
  445. help
  446. This option enables support for Promise Serial ATA SX4.
  447. If unsure, say N.
  448. config SCSI_SATA_SIL
  449. tristate "Silicon Image SATA support"
  450. depends on SCSI_SATA && PCI && EXPERIMENTAL
  451. help
  452. This option enables support for Silicon Image Serial ATA.
  453. If unsure, say N.
  454. config SCSI_SATA_SIL24
  455. tristate "Silicon Image 3124/3132 SATA support"
  456. depends on SCSI_SATA && PCI && EXPERIMENTAL
  457. help
  458. This option enables support for Silicon Image 3124/3132 Serial ATA.
  459. If unsure, say N.
  460. config SCSI_SATA_SIS
  461. tristate "SiS 964/180 SATA support"
  462. depends on SCSI_SATA && PCI && EXPERIMENTAL
  463. help
  464. This option enables support for SiS Serial ATA 964/180.
  465. If unsure, say N.
  466. config SCSI_SATA_ULI
  467. tristate "ULi Electronics SATA support"
  468. depends on SCSI_SATA && PCI && EXPERIMENTAL
  469. help
  470. This option enables support for ULi Electronics SATA.
  471. If unsure, say N.
  472. config SCSI_SATA_VIA
  473. tristate "VIA SATA support"
  474. depends on SCSI_SATA && PCI
  475. help
  476. This option enables support for VIA Serial ATA.
  477. If unsure, say N.
  478. config SCSI_SATA_VITESSE
  479. tristate "VITESSE VSC-7174 SATA support"
  480. depends on SCSI_SATA && PCI
  481. help
  482. This option enables support for Vitesse VSC7174 Serial ATA.
  483. If unsure, say N.
  484. config SCSI_SATA_INTEL_COMBINED
  485. bool
  486. depends on IDE=y && !BLK_DEV_IDE_SATA && (SCSI_SATA_AHCI || SCSI_ATA_PIIX)
  487. default y
  488. config SCSI_BUSLOGIC
  489. tristate "BusLogic SCSI support"
  490. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API
  491. ---help---
  492. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  493. Adapters. Consult the SCSI-HOWTO, available from
  494. <http://www.tldp.org/docs.html#howto>, and the files
  495. <file:Documentation/scsi/BusLogic.txt> and
  496. <file:Documentation/scsi/FlashPoint.txt> for more information.
  497. To compile this driver as a module, choose M here: the
  498. module will be called BusLogic.
  499. config SCSI_OMIT_FLASHPOINT
  500. bool "Omit FlashPoint support"
  501. depends on SCSI_BUSLOGIC
  502. help
  503. This option allows you to omit the FlashPoint support from the
  504. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  505. substantial, so users of MultiMaster Host Adapters may wish to omit
  506. it.
  507. config SCSI_DMX3191D
  508. tristate "DMX3191D SCSI support"
  509. depends on PCI && SCSI
  510. select SCSI_SPI_ATTRS
  511. help
  512. This is support for Domex DMX3191D SCSI Host Adapters.
  513. To compile this driver as a module, choose M here: the
  514. module will be called dmx3191d.
  515. config SCSI_DTC3280
  516. tristate "DTC3180/3280 SCSI support"
  517. depends on ISA && SCSI
  518. select SCSI_SPI_ATTRS
  519. help
  520. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  521. the SCSI-HOWTO, available from
  522. <http://www.tldp.org/docs.html#howto>, and the file
  523. <file:Documentation/scsi/dtc3x80.txt>.
  524. To compile this driver as a module, choose M here: the
  525. module will be called dtc.
  526. config SCSI_EATA
  527. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  528. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  529. ---help---
  530. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  531. ISA and all EISA I/O addresses are probed looking for the "EATA"
  532. signature. The addresses of all the PCI SCSI controllers reported
  533. by the PCI subsystem are probed as well.
  534. You want to read the start of <file:drivers/scsi/eata.c> and the
  535. SCSI-HOWTO, available from
  536. <http://www.tldp.org/docs.html#howto>.
  537. To compile this driver as a module, choose M here: the
  538. module will be called eata.
  539. config SCSI_EATA_TAGGED_QUEUE
  540. bool "enable tagged command queueing"
  541. depends on SCSI_EATA
  542. help
  543. This is a feature of SCSI-2 which improves performance: the host
  544. adapter can send several SCSI commands to a device's queue even if
  545. previous commands haven't finished yet.
  546. This is equivalent to the "eata=tc:y" boot option.
  547. config SCSI_EATA_LINKED_COMMANDS
  548. bool "enable elevator sorting"
  549. depends on SCSI_EATA
  550. help
  551. This option enables elevator sorting for all probed SCSI disks and
  552. CD-ROMs. It definitely reduces the average seek distance when doing
  553. random seeks, but this does not necessarily result in a noticeable
  554. performance improvement: your mileage may vary...
  555. This is equivalent to the "eata=lc:y" boot option.
  556. config SCSI_EATA_MAX_TAGS
  557. int "maximum number of queued commands"
  558. depends on SCSI_EATA
  559. default "16"
  560. help
  561. This specifies how many SCSI commands can be maximally queued for
  562. each probed SCSI device. You should reduce the default value of 16
  563. only if you have disks with buggy or limited tagged command support.
  564. Minimum is 2 and maximum is 62. This value is also the window size
  565. used by the elevator sorting option above. The effective value used
  566. by the driver for each probed SCSI device is reported at boot time.
  567. This is equivalent to the "eata=mq:8" boot option.
  568. config SCSI_EATA_PIO
  569. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  570. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  571. ---help---
  572. This driver supports all EATA-PIO protocol compliant SCSI Host
  573. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  574. host adapters could also use this driver but are discouraged from
  575. doing so, since this driver only supports hard disks and lacks
  576. numerous features. You might want to have a look at the SCSI-HOWTO,
  577. available from <http://www.tldp.org/docs.html#howto>.
  578. To compile this driver as a module, choose M here: the
  579. module will be called eata_pio.
  580. config SCSI_FUTURE_DOMAIN
  581. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  582. depends on (ISA || PCI) && SCSI
  583. ---help---
  584. This is support for Future Domain's 16-bit SCSI host adapters
  585. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  586. other adapters based on the Future Domain chipsets (Quantum
  587. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  588. It is explained in section 3.7 of the SCSI-HOWTO, available from
  589. <http://www.tldp.org/docs.html#howto>.
  590. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  591. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  592. controller support"). This Future Domain driver works with the older
  593. Adaptec AHA-2920A boards with a Future Domain chip on them.
  594. To compile this driver as a module, choose M here: the
  595. module will be called fdomain.
  596. config SCSI_FD_MCS
  597. tristate "Future Domain MCS-600/700 SCSI support"
  598. depends on MCA_LEGACY && SCSI
  599. ---help---
  600. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  601. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  602. is identical to the MCS 700 and hence also supported by this driver.
  603. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  604. It supports multiple adapters in the same system.
  605. To compile this driver as a module, choose M here: the
  606. module will be called fd_mcs.
  607. config SCSI_GDTH
  608. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  609. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  610. ---help---
  611. Formerly called GDT SCSI Disk Array Controller Support.
  612. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  613. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  614. in the kernel source in <file:drivers/scsi/gdth.c> and
  615. <file:drivers/scsi/gdth.h.>
  616. To compile this driver as a module, choose M here: the
  617. module will be called gdth.
  618. config SCSI_GENERIC_NCR5380
  619. tristate "Generic NCR5380/53c400 SCSI PIO support"
  620. depends on ISA && SCSI
  621. select SCSI_SPI_ATTRS
  622. ---help---
  623. This is a driver for the old NCR 53c80 series of SCSI controllers
  624. on boards using PIO. Most boards such as the Trantor T130 fit this
  625. category, along with a large number of ISA 8bit controllers shipped
  626. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  627. you should select the specific driver for that card rather than
  628. generic 5380 support.
  629. It is explained in section 3.8 of the SCSI-HOWTO, available from
  630. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  631. of the box, you may have to change some settings in
  632. <file:drivers/scsi/g_NCR5380.h>.
  633. To compile this driver as a module, choose M here: the
  634. module will be called g_NCR5380.
  635. config SCSI_GENERIC_NCR5380_MMIO
  636. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  637. depends on ISA && SCSI
  638. select SCSI_SPI_ATTRS
  639. ---help---
  640. This is a driver for the old NCR 53c80 series of SCSI controllers
  641. on boards using memory mapped I/O.
  642. It is explained in section 3.8 of the SCSI-HOWTO, available from
  643. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  644. of the box, you may have to change some settings in
  645. <file:drivers/scsi/g_NCR5380.h>.
  646. To compile this driver as a module, choose M here: the
  647. module will be called g_NCR5380_mmio.
  648. config SCSI_GENERIC_NCR53C400
  649. bool "Enable NCR53c400 extensions"
  650. depends on SCSI_GENERIC_NCR5380
  651. help
  652. This enables certain optimizations for the NCR53c400 SCSI cards.
  653. You might as well try it out. Note that this driver will only probe
  654. for the Trantor T130B in its default configuration; you might have
  655. to pass a command line option to the kernel at boot time if it does
  656. not detect your card. See the file
  657. <file:Documentation/scsi/g_NCR5380.txt> for details.
  658. config SCSI_IBMMCA
  659. tristate "IBMMCA SCSI support"
  660. depends on MCA_LEGACY && SCSI
  661. ---help---
  662. This is support for the IBM SCSI adapter found in many of the PS/2
  663. series computers. These machines have an MCA bus, so you need to
  664. answer Y to "MCA support" as well and read
  665. <file:Documentation/mca.txt>.
  666. If the adapter isn't found during boot (a common problem for models
  667. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  668. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  669. if that doesn't work check your reference diskette). Owners of
  670. model 95 with a LED-matrix-display can in addition activate some
  671. activity info like under OS/2, but more informative, by setting
  672. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  673. bootparam" or see the documentation of your boot loader about how to
  674. pass options to the kernel.
  675. To compile this driver as a module, choose M here: the
  676. module will be called ibmmca.
  677. config IBMMCA_SCSI_ORDER_STANDARD
  678. bool "Standard SCSI-order"
  679. depends on SCSI_IBMMCA
  680. ---help---
  681. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  682. are assigned to the drive letters, starting with the lowest SCSI-id
  683. (physical number -- pun) to be drive C:, as seen from DOS and
  684. similar operating systems. When looking into papers describing the
  685. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  686. The SCSI-standard follows a hardware-hierarchy which says that id 7
  687. has the highest priority and id 0 the lowest. Therefore, the host
  688. adapters are still today everywhere placed as SCSI-id 7 by default.
  689. In the SCSI-standard, the drive letters express the priority of the
  690. disk. C: should be the hard disk, or a partition on it, with the
  691. highest priority. This must therefore be the disk with the highest
  692. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  693. original definition of the SCSI-standard as also industrial- and
  694. process-control-machines, like VME-CPUs running under realtime-OSes
  695. (e.g. LynxOS, OS9) do.
  696. If you like to run Linux on your MCA-machine with the same
  697. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  698. machine, which is in addition conformant to the SCSI-standard, you
  699. must say Y here. This is also necessary for MCA-Linux users who want
  700. to keep downward compatibility to older releases of the
  701. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  702. June 1997).
  703. If you like to have the lowest SCSI-id assigned as drive C:, as
  704. modern SCSI-BIOSes do, which does not conform to the standard, but
  705. is widespread and common in the PC-world of today, you must say N
  706. here. If unsure, say Y.
  707. config IBMMCA_SCSI_DEV_RESET
  708. bool "Reset SCSI-devices at boottime"
  709. depends on SCSI_IBMMCA
  710. ---help---
  711. By default, SCSI-devices are reset when the machine is powered on.
  712. However, some devices exist, like special-control-devices,
  713. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  714. not reset when switched on. If you say Y here, each device connected
  715. to your SCSI-bus will be issued a reset-command after it has been
  716. probed, while the kernel is booting. This may cause problems with
  717. more modern devices, like hard disks, which do not appreciate these
  718. reset commands, and can cause your system to hang. So say Y only if
  719. you know that one of your older devices needs it; N is the safe
  720. answer.
  721. config SCSI_IPS
  722. tristate "IBM ServeRAID support"
  723. depends on PCI && SCSI
  724. ---help---
  725. This is support for the IBM ServeRAID hardware RAID controllers.
  726. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  727. for more information. If this driver does not work correctly
  728. without modification please contact the author by email at
  729. <ipslinux@adaptec.com>.
  730. To compile this driver as a module, choose M here: the
  731. module will be called ips.
  732. config SCSI_IBMVSCSI
  733. tristate "IBM Virtual SCSI support"
  734. depends on PPC_PSERIES || PPC_ISERIES
  735. help
  736. This is the IBM POWER Virtual SCSI Client
  737. To compile this driver as a module, choose M here: the
  738. module will be called ibmvscsic.
  739. config SCSI_INITIO
  740. tristate "Initio 9100U(W) support"
  741. depends on PCI && SCSI
  742. help
  743. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  744. read the SCSI-HOWTO, available from
  745. <http://www.tldp.org/docs.html#howto>.
  746. To compile this driver as a module, choose M here: the
  747. module will be called initio.
  748. config SCSI_INIA100
  749. tristate "Initio INI-A100U2W support"
  750. depends on PCI && SCSI
  751. help
  752. This is support for the Initio INI-A100U2W SCSI host adapter.
  753. Please read the SCSI-HOWTO, available from
  754. <http://www.tldp.org/docs.html#howto>.
  755. To compile this driver as a module, choose M here: the
  756. module will be called a100u2w.
  757. config SCSI_PPA
  758. tristate "IOMEGA parallel port (ppa - older drives)"
  759. depends on SCSI && PARPORT_PC
  760. ---help---
  761. This driver supports older versions of IOMEGA's parallel port ZIP
  762. drive (a 100 MB removable media device).
  763. Note that you can say N here if you have the SCSI version of the ZIP
  764. drive: it will be supported automatically if you said Y to the
  765. generic "SCSI disk support", above.
  766. If you have the ZIP Plus drive or a more recent parallel port ZIP
  767. drive (if the supplied cable with the drive is labeled "AutoDetect")
  768. then you should say N here and Y to "IOMEGA parallel port (imm -
  769. newer drives)", below.
  770. For more information about this driver and how to use it you should
  771. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  772. the SCSI-HOWTO, which is available from
  773. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  774. you will still be able to use the parallel port for other tasks,
  775. such as a printer; it is safe to compile both drivers into the
  776. kernel.
  777. To compile this driver as a module, choose M here: the
  778. module will be called ppa.
  779. config SCSI_IMM
  780. tristate "IOMEGA parallel port (imm - newer drives)"
  781. depends on SCSI && PARPORT_PC
  782. ---help---
  783. This driver supports newer versions of IOMEGA's parallel port ZIP
  784. drive (a 100 MB removable media device).
  785. Note that you can say N here if you have the SCSI version of the ZIP
  786. drive: it will be supported automatically if you said Y to the
  787. generic "SCSI disk support", above.
  788. If you have the ZIP Plus drive or a more recent parallel port ZIP
  789. drive (if the supplied cable with the drive is labeled "AutoDetect")
  790. then you should say Y here; if you have an older ZIP drive, say N
  791. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  792. For more information about this driver and how to use it you should
  793. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  794. the SCSI-HOWTO, which is available from
  795. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  796. you will still be able to use the parallel port for other tasks,
  797. such as a printer; it is safe to compile both drivers into the
  798. kernel.
  799. To compile this driver as a module, choose M here: the
  800. module will be called imm.
  801. config SCSI_IZIP_EPP16
  802. bool "ppa/imm option - Use slow (but safe) EPP-16"
  803. depends on SCSI_PPA || SCSI_IMM
  804. ---help---
  805. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  806. allows them to act as expansion buses that can handle up to 64
  807. peripheral devices.
  808. Some parallel port chipsets are slower than their motherboard, and
  809. so we have to control the state of the chipset's FIFO queue every
  810. now and then to avoid data loss. This will be done if you say Y
  811. here.
  812. Generally, saying Y is the safe option and slows things down a bit.
  813. config SCSI_IZIP_SLOW_CTR
  814. bool "ppa/imm option - Assume slow parport control register"
  815. depends on SCSI_PPA || SCSI_IMM
  816. help
  817. Some parallel ports are known to have excessive delays between
  818. changing the parallel port control register and good data being
  819. available on the parallel port data/status register. This option
  820. forces a small delay (1.0 usec to be exact) after changing the
  821. control register to let things settle out. Enabling this option may
  822. result in a big drop in performance but some very old parallel ports
  823. (found in 386 vintage machines) will not work properly.
  824. Generally, saying N is fine.
  825. config SCSI_NCR53C406A
  826. tristate "NCR53c406a SCSI support"
  827. depends on ISA && SCSI
  828. help
  829. This is support for the NCR53c406a SCSI host adapter. For user
  830. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  831. in the kernel source. Also read the SCSI-HOWTO, available from
  832. <http://www.tldp.org/docs.html#howto>.
  833. To compile this driver as a module, choose M here: the
  834. module will be called NCR53c406.
  835. config SCSI_NCR_D700
  836. tristate "NCR Dual 700 MCA SCSI support"
  837. depends on MCA && SCSI
  838. select SCSI_SPI_ATTRS
  839. help
  840. This is a driver for the MicroChannel Dual 700 card produced by
  841. NCR and commonly used in 345x/35xx/4100 class machines. It always
  842. tries to negotiate sync and uses tag command queueing.
  843. Unless you have an NCR manufactured machine, the chances are that
  844. you do not have this SCSI card, so say N.
  845. config SCSI_LASI700
  846. tristate "HP Lasi SCSI support for 53c700/710"
  847. depends on GSC && SCSI
  848. select SCSI_SPI_ATTRS
  849. help
  850. This is a driver for the SCSI controller in the Lasi chip found in
  851. many PA-RISC workstations & servers. If you do not know whether you
  852. have a Lasi chip, it is safe to say "Y" here.
  853. config 53C700_LE_ON_BE
  854. bool
  855. depends on SCSI_LASI700
  856. default y
  857. config SCSI_SYM53C8XX_2
  858. tristate "SYM53C8XX Version 2 SCSI support"
  859. depends on PCI && SCSI
  860. select SCSI_SPI_ATTRS
  861. ---help---
  862. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  863. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  864. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  865. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  866. controllers; you need to use the Fusion MPT driver for that.
  867. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  868. information.
  869. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  870. int "DMA addressing mode"
  871. depends on SCSI_SYM53C8XX_2
  872. default "1"
  873. ---help---
  874. This option only applies to PCI-SCSI chips that are PCI DAC
  875. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  876. When set to 0, the driver will program the chip to only perform
  877. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  878. to addresses up to 1TB. When set to 2, the driver supports the
  879. full 64-bit DMA address range, but can only address 16 segments
  880. of 4 GB each. This limits the total addressable range to 64 GB.
  881. Most machines with less than 4GB of memory should use a setting
  882. of 0 for best performance. If your machine has 4GB of memory
  883. or more, you should set this option to 1 (the default).
  884. The still experimental value 2 (64 bit DMA addressing with 16
  885. x 4GB segments limitation) can be used on systems that require
  886. PCI address bits past bit 39 to be set for the addressing of
  887. memory using PCI DAC cycles.
  888. config SCSI_SYM53C8XX_DEFAULT_TAGS
  889. int "default tagged command queue depth"
  890. depends on SCSI_SYM53C8XX_2
  891. default "16"
  892. help
  893. This is the default value of the command queue depth the
  894. driver will announce to the generic SCSI layer for devices
  895. that support tagged command queueing. This value can be changed
  896. from the boot command line. This is a soft limit that cannot
  897. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  898. config SCSI_SYM53C8XX_MAX_TAGS
  899. int "maximum number of queued commands"
  900. depends on SCSI_SYM53C8XX_2
  901. default "64"
  902. help
  903. This option allows you to specify the maximum number of commands
  904. that can be queued to any device, when tagged command queuing is
  905. possible. The driver supports up to 256 queued commands per device.
  906. This value is used as a compiled-in hard limit.
  907. config SCSI_SYM53C8XX_IOMAPPED
  908. bool "use port IO"
  909. depends on SCSI_SYM53C8XX_2
  910. help
  911. If you say Y here, the driver will use port IO to access
  912. the card. This is significantly slower then using memory
  913. mapped IO. Most people should answer N.
  914. config SCSI_IPR
  915. tristate "IBM Power Linux RAID adapter support"
  916. depends on PCI && SCSI
  917. select FW_LOADER
  918. ---help---
  919. This driver supports the IBM Power Linux family RAID adapters.
  920. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  921. as IBM iSeries 5702, 5703, 5709, and 570A.
  922. config SCSI_IPR_TRACE
  923. bool "enable driver internal trace"
  924. depends on SCSI_IPR
  925. help
  926. If you say Y here, the driver will trace all commands issued
  927. to the adapter. Performance impact is minimal. Trace can be
  928. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  929. config SCSI_IPR_DUMP
  930. bool "enable adapter dump support"
  931. depends on SCSI_IPR
  932. help
  933. If you say Y here, the driver will support adapter crash dump.
  934. If you enable this support, the iprdump daemon can be used
  935. to capture adapter failure analysis information.
  936. config SCSI_ZALON
  937. tristate "Zalon SCSI support"
  938. depends on GSC && SCSI
  939. select SCSI_SPI_ATTRS
  940. help
  941. The Zalon is a GSC/HSC bus interface chip that sits between the
  942. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  943. C110, J200, J210 and some D, K & R-class machines. It's also
  944. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  945. Say Y here if you have one of these machines or cards.
  946. config SCSI_NCR_Q720
  947. tristate "NCR Quad 720 MCA SCSI support"
  948. depends on MCA && SCSI
  949. select SCSI_SPI_ATTRS
  950. help
  951. This is a driver for the MicroChannel Quad 720 card produced by
  952. NCR and commonly used in 345x/35xx/4100 class machines. It always
  953. tries to negotiate sync and uses tag command queueing.
  954. Unless you have an NCR manufactured machine, the chances are that
  955. you do not have this SCSI card, so say N.
  956. config SCSI_NCR53C8XX_DEFAULT_TAGS
  957. int " default tagged command queue depth"
  958. depends on SCSI_ZALON || SCSI_NCR_Q720
  959. default "8"
  960. ---help---
  961. "Tagged command queuing" is a feature of SCSI-2 which improves
  962. performance: the host adapter can send several SCSI commands to a
  963. device's queue even if previous commands haven't finished yet.
  964. Because the device is intelligent, it can optimize its operations
  965. (like head positioning) based on its own request queue. Some SCSI
  966. devices don't implement this properly; if you want to disable this
  967. feature, enter 0 or 1 here (it doesn't matter which).
  968. The default value is 8 and should be supported by most hard disks.
  969. This value can be overridden from the boot command line using the
  970. 'tags' option as follows (example):
  971. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  972. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  973. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  974. The normal answer therefore is to go with the default 8 and to use
  975. a boot command line option for devices that need to use a different
  976. command queue depth.
  977. There is no safe option other than using good SCSI devices.
  978. config SCSI_NCR53C8XX_MAX_TAGS
  979. int " maximum number of queued commands"
  980. depends on SCSI_ZALON || SCSI_NCR_Q720
  981. default "32"
  982. ---help---
  983. This option allows you to specify the maximum number of commands
  984. that can be queued to any device, when tagged command queuing is
  985. possible. The default value is 32. Minimum is 2, maximum is 64.
  986. Modern hard disks are able to support 64 tags and even more, but
  987. do not seem to be faster when more than 32 tags are being used.
  988. So, the normal answer here is to go with the default value 32 unless
  989. you are using very large hard disks with large cache (>= 1 MB) that
  990. are able to take advantage of more than 32 tagged commands.
  991. There is no safe option and the default answer is recommended.
  992. config SCSI_NCR53C8XX_SYNC
  993. int " synchronous transfers frequency in MHz"
  994. depends on SCSI_ZALON || SCSI_NCR_Q720
  995. default "20"
  996. ---help---
  997. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  998. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  999. are respectively the maximum data transfer rates in mega-transfers
  1000. per second for each class. For example, a FAST-20 Wide 16 device is
  1001. able to transfer data at 20 million 16 bit packets per second for a
  1002. total rate of 40 MB/s.
  1003. You may specify 0 if you want to only use asynchronous data
  1004. transfers. This is the safest and slowest option. Otherwise, specify
  1005. a value between 5 and 80, depending on the capability of your SCSI
  1006. controller. The higher the number, the faster the data transfer.
  1007. Note that 80 should normally be ok since the driver decreases the
  1008. value automatically according to the controller's capabilities.
  1009. Your answer to this question is ignored for controllers with NVRAM,
  1010. since the driver will get this information from the user set-up. It
  1011. also can be overridden using a boot setup option, as follows
  1012. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  1013. for FAST-20 synchronous data transfer (20 mega-transfers per
  1014. second).
  1015. The normal answer therefore is not to go with the default but to
  1016. select the maximum value 80 allowing the driver to use the maximum
  1017. value supported by each controller. If this causes problems with
  1018. your SCSI devices, you should come back and decrease the value.
  1019. There is no safe option other than using good cabling, right
  1020. terminations and SCSI conformant devices.
  1021. config SCSI_NCR53C8XX_PROFILE
  1022. bool " enable profiling"
  1023. depends on SCSI_ZALON || SCSI_NCR_Q720
  1024. help
  1025. This option allows you to enable profiling information gathering.
  1026. These statistics are not very accurate due to the low frequency
  1027. of the kernel clock (100 Hz on i386) and have performance impact
  1028. on systems that use very fast devices.
  1029. The normal answer therefore is N.
  1030. config SCSI_NCR53C8XX_NO_DISCONNECT
  1031. bool " not allow targets to disconnect"
  1032. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  1033. help
  1034. This option is only provided for safety if you suspect some SCSI
  1035. device of yours to not support properly the target-disconnect
  1036. feature. In that case, you would say Y here. In general however, to
  1037. not allow targets to disconnect is not reasonable if there is more
  1038. than 1 device on a SCSI bus. The normal answer therefore is N.
  1039. config SCSI_MCA_53C9X
  1040. tristate "NCR MCA 53C9x SCSI support"
  1041. depends on MCA_LEGACY && SCSI && BROKEN_ON_SMP
  1042. help
  1043. Some MicroChannel machines, notably the NCR 35xx line, use a SCSI
  1044. controller based on the NCR 53C94. This driver will allow use of
  1045. the controller on the 3550, and very possibly others.
  1046. To compile this driver as a module, choose M here: the
  1047. module will be called mca_53c9x.
  1048. config SCSI_PAS16
  1049. tristate "PAS16 SCSI support"
  1050. depends on ISA && SCSI
  1051. select SCSI_SPI_ATTRS
  1052. ---help---
  1053. This is support for a SCSI host adapter. It is explained in section
  1054. 3.10 of the SCSI-HOWTO, available from
  1055. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1056. of the box, you may have to change some settings in
  1057. <file:drivers/scsi/pas16.h>.
  1058. To compile this driver as a module, choose M here: the
  1059. module will be called pas16.
  1060. config SCSI_PSI240I
  1061. tristate "PSI240i support"
  1062. depends on ISA && SCSI
  1063. help
  1064. This is support for the PSI240i EIDE interface card which acts as a
  1065. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1066. <http://www.tldp.org/docs.html#howto>.
  1067. To compile this driver as a module, choose M here: the
  1068. module will be called psi240i.
  1069. config SCSI_QLOGIC_FAS
  1070. tristate "Qlogic FAS SCSI support"
  1071. depends on ISA && SCSI
  1072. ---help---
  1073. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1074. FastSCSI! cards as well as any other card based on the FASXX chip
  1075. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1076. This driver does NOT support the PCI versions of these cards. The
  1077. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1078. SCSI support"), below.
  1079. Information about this driver is contained in
  1080. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1081. SCSI-HOWTO, available from
  1082. <http://www.tldp.org/docs.html#howto>.
  1083. To compile this driver as a module, choose M here: the
  1084. module will be called qlogicfas.
  1085. config SCSI_QLOGIC_FC
  1086. tristate "Qlogic ISP FC SCSI support"
  1087. depends on PCI && SCSI
  1088. help
  1089. This is a driver for the QLogic ISP2100 SCSI-FCP host adapter.
  1090. To compile this driver as a module, choose M here: the
  1091. module will be called qlogicfc.
  1092. config SCSI_QLOGIC_FC_FIRMWARE
  1093. bool "Include loadable firmware in driver"
  1094. depends on SCSI_QLOGIC_FC
  1095. help
  1096. Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
  1097. expanded LUN addressing and FcTape (FCP-2) support, in the
  1098. qlogicfc driver. This is required on some platforms.
  1099. config SCSI_QLOGIC_1280
  1100. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1101. depends on PCI && SCSI
  1102. help
  1103. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1104. To compile this driver as a module, choose M here: the
  1105. module will be called qla1280.
  1106. config SCSI_QLOGICPTI
  1107. tristate "PTI Qlogic, ISP Driver"
  1108. depends on SBUS && SCSI
  1109. help
  1110. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1111. controllers are known under Solaris as qpti and in the openprom as
  1112. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1113. driven by a different driver.
  1114. To compile this driver as a module, choose M here: the
  1115. module will be called qlogicpti.
  1116. source "drivers/scsi/qla2xxx/Kconfig"
  1117. config SCSI_LPFC
  1118. tristate "Emulex LightPulse Fibre Channel Support"
  1119. depends on PCI && SCSI
  1120. select SCSI_FC_ATTRS
  1121. help
  1122. This lpfc driver supports the Emulex LightPulse
  1123. Family of Fibre Channel PCI host adapters.
  1124. config SCSI_SEAGATE
  1125. tristate "Seagate ST-02 and Future Domain TMC-8xx SCSI support"
  1126. depends on X86 && ISA && SCSI && BROKEN
  1127. ---help---
  1128. These are 8-bit SCSI controllers; the ST-01 is also supported by
  1129. this driver. It is explained in section 3.9 of the SCSI-HOWTO,
  1130. available from <http://www.tldp.org/docs.html#howto>. If it
  1131. doesn't work out of the box, you may have to change some settings in
  1132. <file:drivers/scsi/seagate.h>.
  1133. To compile this driver as a module, choose M here: the
  1134. module will be called seagate.
  1135. # definitely looks not 64bit safe:
  1136. config SCSI_SIM710
  1137. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1138. depends on (EISA || MCA) && SCSI
  1139. select SCSI_SPI_ATTRS
  1140. ---help---
  1141. This driver for NCR53c710 based SCSI host adapters.
  1142. It currently supports Compaq EISA cards and NCR MCA cards
  1143. config 53C700_IO_MAPPED
  1144. bool
  1145. depends on SCSI_SIM710
  1146. default y
  1147. config SCSI_SYM53C416
  1148. tristate "Symbios 53c416 SCSI support"
  1149. depends on ISA && SCSI
  1150. ---help---
  1151. This is support for the sym53c416 SCSI host adapter, the SCSI
  1152. adapter that comes with some HP scanners. This driver requires that
  1153. the sym53c416 is configured first using some sort of PnP
  1154. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1155. are using isapnp then you need to compile this driver as a module
  1156. and then load it using insmod after isapnp has run. The parameters
  1157. of the configured card(s) should be passed to the driver. The format
  1158. is:
  1159. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1160. To compile this driver as a module, choose M here: the
  1161. module will be called sym53c416.
  1162. config SCSI_DC395x
  1163. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1164. depends on PCI && SCSI && EXPERIMENTAL
  1165. ---help---
  1166. This driver supports PCI SCSI host adapters based on the ASIC
  1167. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1168. This driver works, but is still in experimental status. So better
  1169. have a bootable disk and a backup in case of emergency.
  1170. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1171. To compile this driver as a module, choose M here: the
  1172. module will be called dc395x.
  1173. config SCSI_DC390T
  1174. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1175. depends on PCI && SCSI
  1176. ---help---
  1177. This driver supports PCI SCSI host adapters based on the Am53C974A
  1178. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1179. PCscsi/PCnet (Am53/79C974) solutions.
  1180. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1181. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1182. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1183. To compile this driver as a module, choose M here: the
  1184. module will be called tmscsim.
  1185. config SCSI_T128
  1186. tristate "Trantor T128/T128F/T228 SCSI support"
  1187. depends on ISA && SCSI
  1188. select SCSI_SPI_ATTRS
  1189. ---help---
  1190. This is support for a SCSI host adapter. It is explained in section
  1191. 3.11 of the SCSI-HOWTO, available from
  1192. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1193. of the box, you may have to change some settings in
  1194. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1195. Adaptec, and some former Trantor products are being sold under the
  1196. Adaptec name.
  1197. To compile this driver as a module, choose M here: the
  1198. module will be called t128.
  1199. config SCSI_U14_34F
  1200. tristate "UltraStor 14F/34F support"
  1201. depends on ISA && SCSI && ISA_DMA_API
  1202. ---help---
  1203. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1204. The source at <file:drivers/scsi/u14-34f.c> contains some
  1205. information about this hardware. If the driver doesn't work out of
  1206. the box, you may have to change some settings in
  1207. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1208. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1209. another driver for the same hardware: "UltraStor SCSI support",
  1210. below. You should say Y to both only if you want 24F support as
  1211. well.
  1212. To compile this driver as a module, choose M here: the
  1213. module will be called u14-34f.
  1214. config SCSI_U14_34F_TAGGED_QUEUE
  1215. bool "enable tagged command queueing"
  1216. depends on SCSI_U14_34F
  1217. help
  1218. This is a feature of SCSI-2 which improves performance: the host
  1219. adapter can send several SCSI commands to a device's queue even if
  1220. previous commands haven't finished yet.
  1221. This is equivalent to the "u14-34f=tc:y" boot option.
  1222. config SCSI_U14_34F_LINKED_COMMANDS
  1223. bool "enable elevator sorting"
  1224. depends on SCSI_U14_34F
  1225. help
  1226. This option enables elevator sorting for all probed SCSI disks and
  1227. CD-ROMs. It definitely reduces the average seek distance when doing
  1228. random seeks, but this does not necessarily result in a noticeable
  1229. performance improvement: your mileage may vary...
  1230. This is equivalent to the "u14-34f=lc:y" boot option.
  1231. config SCSI_U14_34F_MAX_TAGS
  1232. int "maximum number of queued commands"
  1233. depends on SCSI_U14_34F
  1234. default "8"
  1235. help
  1236. This specifies how many SCSI commands can be maximally queued for
  1237. each probed SCSI device. You should reduce the default value of 8
  1238. only if you have disks with buggy or limited tagged command support.
  1239. Minimum is 2 and maximum is 14. This value is also the window size
  1240. used by the elevator sorting option above. The effective value used
  1241. by the driver for each probed SCSI device is reported at boot time.
  1242. This is equivalent to the "u14-34f=mq:8" boot option.
  1243. config SCSI_ULTRASTOR
  1244. tristate "UltraStor SCSI support"
  1245. depends on X86 && ISA && SCSI
  1246. ---help---
  1247. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1248. adapter family. This driver is explained in section 3.12 of the
  1249. SCSI-HOWTO, available from
  1250. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1251. of the box, you may have to change some settings in
  1252. <file:drivers/scsi/ultrastor.h>.
  1253. Note that there is also another driver for the same hardware:
  1254. "UltraStor 14F/34F support", above.
  1255. To compile this driver as a module, choose M here: the
  1256. module will be called ultrastor.
  1257. config SCSI_NSP32
  1258. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1259. depends on PCI && SCSI && !64BIT
  1260. help
  1261. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1262. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1263. <http://www.tldp.org/docs.html#howto>.
  1264. To compile this driver as a module, choose M here: the
  1265. module will be called nsp32.
  1266. config SCSI_DEBUG
  1267. tristate "SCSI debugging host simulator"
  1268. depends on SCSI
  1269. help
  1270. This is a host adapter simulator that can simulate multiple hosts
  1271. each with multiple dummy SCSI devices (disks). It defaults to one
  1272. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1273. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1274. dummy disks are simulated, they share the same kernel RAM for
  1275. their storage. See <http://www.torque.net/sg/sdebug.html> for more
  1276. information. This driver is primarily of use to those testing the
  1277. SCSI and block subsystems. If unsure, say N.
  1278. config SCSI_MESH
  1279. tristate "MESH (Power Mac internal SCSI) support"
  1280. depends on PPC32 && PPC_PMAC && SCSI
  1281. help
  1282. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1283. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1284. other Power Macintoshes do). Say Y to include support for this SCSI
  1285. adaptor.
  1286. To compile this driver as a module, choose M here: the
  1287. module will be called mesh.
  1288. config SCSI_MESH_SYNC_RATE
  1289. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1290. depends on SCSI_MESH
  1291. default "5"
  1292. help
  1293. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1294. drives a bus which is entirely internal to the machine (such as the
  1295. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1296. operation at up to 10 MB/s. On machines where the SCSI bus
  1297. controlled by the MESH can have external devices connected, it is
  1298. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1299. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1300. to disable synchronous operation.
  1301. config SCSI_MESH_RESET_DELAY_MS
  1302. int "initial bus reset delay (ms) (0 = no reset)"
  1303. depends on SCSI_MESH
  1304. default "4000"
  1305. config SCSI_MAC53C94
  1306. tristate "53C94 (Power Mac external SCSI) support"
  1307. depends on PPC32 && PPC_PMAC && SCSI
  1308. help
  1309. On Power Macintoshes (and clones) with two SCSI buses, the external
  1310. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1311. machines which only have one SCSI bus, such as the 7200, also use
  1312. the 53C94. Say Y to include support for the 53C94.
  1313. To compile this driver as a module, choose M here: the
  1314. module will be called mac53c94.
  1315. source "drivers/scsi/arm/Kconfig"
  1316. config JAZZ_ESP
  1317. bool "MIPS JAZZ FAS216 SCSI support"
  1318. depends on MACH_JAZZ && SCSI
  1319. help
  1320. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1321. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1322. systems.
  1323. config A3000_SCSI
  1324. tristate "A3000 WD33C93A support"
  1325. depends on AMIGA && SCSI
  1326. help
  1327. If you have an Amiga 3000 and have SCSI devices connected to the
  1328. built-in SCSI controller, say Y. Otherwise, say N.
  1329. To compile this driver as a module, choose M here: the
  1330. module will be called wd33c93.
  1331. config A2091_SCSI
  1332. tristate "A2091/A590 WD33C93A support"
  1333. depends on ZORRO && SCSI
  1334. help
  1335. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1336. say N.
  1337. To compile this driver as a module, choose M here: the
  1338. module will be called wd33c93.
  1339. config GVP11_SCSI
  1340. tristate "GVP Series II WD33C93A support"
  1341. depends on ZORRO && SCSI
  1342. ---help---
  1343. If you have a Great Valley Products Series II SCSI controller,
  1344. answer Y. Also say Y if you have a later model of GVP SCSI
  1345. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1346. answer N. This driver does NOT work for the T-Rex series of
  1347. accelerators from TekMagic and GVP-M.
  1348. To compile this driver as a module, choose M here: the
  1349. module will be called gvp11.
  1350. config CYBERSTORM_SCSI
  1351. tristate "CyberStorm SCSI support"
  1352. depends on ZORRO && SCSI
  1353. help
  1354. If you have an Amiga with an original (MkI) Phase5 Cyberstorm
  1355. accelerator board and the optional Cyberstorm SCSI controller,
  1356. answer Y. Otherwise, say N.
  1357. config CYBERSTORMII_SCSI
  1358. tristate "CyberStorm Mk II SCSI support"
  1359. depends on ZORRO && SCSI
  1360. help
  1361. If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
  1362. and the optional Cyberstorm SCSI controller, say Y. Otherwise,
  1363. answer N.
  1364. config BLZ2060_SCSI
  1365. tristate "Blizzard 2060 SCSI support"
  1366. depends on ZORRO && SCSI
  1367. help
  1368. If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
  1369. and want to use the onboard SCSI controller, say Y. Otherwise,
  1370. answer N.
  1371. config BLZ1230_SCSI
  1372. tristate "Blizzard 1230IV/1260 SCSI support"
  1373. depends on ZORRO && SCSI
  1374. help
  1375. If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
  1376. 1260 accelerator, and the optional SCSI module, say Y. Otherwise,
  1377. say N.
  1378. config FASTLANE_SCSI
  1379. tristate "Fastlane SCSI support"
  1380. depends on ZORRO && SCSI
  1381. help
  1382. If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
  1383. one in the near future, say Y to this question. Otherwise, say N.
  1384. config SCSI_AMIGA7XX
  1385. bool "Amiga NCR53c710 SCSI support (EXPERIMENTAL)"
  1386. depends on AMIGA && SCSI && EXPERIMENTAL && BROKEN
  1387. help
  1388. Support for various NCR53c710-based SCSI controllers on the Amiga.
  1389. This includes:
  1390. - the builtin SCSI controller on the Amiga 4000T,
  1391. - the Amiga 4091 Zorro III SCSI-2 controller,
  1392. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1393. (info at
  1394. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1395. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1396. accelerator card for the Amiga 1200,
  1397. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1398. Note that all of the above SCSI controllers, except for the builtin
  1399. SCSI controller on the Amiga 4000T, reside on the Zorro expansion
  1400. bus, so you also have to enable Zorro bus support if you want to use
  1401. them.
  1402. config OKTAGON_SCSI
  1403. tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
  1404. depends on ZORRO && SCSI && EXPERIMENTAL
  1405. help
  1406. If you have the BSC Oktagon SCSI disk controller for the Amiga, say
  1407. Y to this question. If you're in doubt about whether you have one,
  1408. see the picture at
  1409. <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
  1410. config ATARI_SCSI
  1411. tristate "Atari native SCSI support"
  1412. depends on ATARI && SCSI && BROKEN
  1413. select SCSI_SPI_ATTRS
  1414. ---help---
  1415. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1416. Falcon, ...) say Y to get it supported. Of course also, if you have
  1417. a compatible SCSI controller (e.g. for Medusa).
  1418. To compile this driver as a module, choose M here: the
  1419. module will be called atari_scsi.
  1420. This driver supports both styles of NCR integration into the
  1421. system: the TT style (separate DMA), and the Falcon style (via
  1422. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1423. in the Hades (without DMA).
  1424. config ATARI_SCSI_TOSHIBA_DELAY
  1425. bool "Long delays for Toshiba CD-ROMs"
  1426. depends on ATARI_SCSI
  1427. help
  1428. This option increases the delay after a SCSI arbitration to
  1429. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1430. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1431. would impact performance a bit, so say N.
  1432. config ATARI_SCSI_RESET_BOOT
  1433. bool "Reset SCSI-devices at boottime"
  1434. depends on ATARI_SCSI
  1435. help
  1436. Reset the devices on your Atari whenever it boots. This makes the
  1437. boot process fractionally longer but may assist recovery from errors
  1438. that leave the devices with SCSI operations partway completed.
  1439. config TT_DMA_EMUL
  1440. bool "Hades SCSI DMA emulator"
  1441. depends on ATARI_SCSI && HADES
  1442. help
  1443. This option enables code which emulates the TT SCSI DMA chip on the
  1444. Hades. This increases the SCSI transfer rates at least ten times
  1445. compared to PIO transfers.
  1446. config MAC_SCSI
  1447. bool "Macintosh NCR5380 SCSI"
  1448. depends on MAC && SCSI=y
  1449. select SCSI_SPI_ATTRS
  1450. help
  1451. This is the NCR 5380 SCSI controller included on most of the 68030
  1452. based Macintoshes. If you have one of these say Y and read the
  1453. SCSI-HOWTO, available from
  1454. <http://www.tldp.org/docs.html#howto>.
  1455. config SCSI_MAC_ESP
  1456. tristate "Macintosh NCR53c9[46] SCSI"
  1457. depends on MAC && SCSI
  1458. help
  1459. This is the NCR 53c9x SCSI controller found on most of the 68040
  1460. based Macintoshes. If you have one of these say Y and read the
  1461. SCSI-HOWTO, available from
  1462. <http://www.tldp.org/docs.html#howto>.
  1463. To compile this driver as a module, choose M here: the
  1464. module will be called mac_esp.
  1465. config MVME147_SCSI
  1466. bool "WD33C93 SCSI driver for MVME147"
  1467. depends on MVME147 && SCSI=y
  1468. select SCSI_SPI_ATTRS
  1469. help
  1470. Support for the on-board SCSI controller on the Motorola MVME147
  1471. single-board computer.
  1472. config MVME16x_SCSI
  1473. bool "NCR53C710 SCSI driver for MVME16x"
  1474. depends on MVME16x && SCSI && BROKEN
  1475. select SCSI_SPI_ATTRS
  1476. help
  1477. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1478. SCSI controller chip. Almost everyone using one of these boards
  1479. will want to say Y to this question.
  1480. config BVME6000_SCSI
  1481. bool "NCR53C710 SCSI driver for BVME6000"
  1482. depends on BVME6000 && SCSI && BROKEN
  1483. select SCSI_SPI_ATTRS
  1484. help
  1485. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1486. SCSI controller chip. Almost everyone using one of these boards
  1487. will want to say Y to this question.
  1488. config SCSI_NCR53C7xx_FAST
  1489. bool "allow FAST-SCSI [10MHz]"
  1490. depends on SCSI_AMIGA7XX || MVME16x_SCSI || BVME6000_SCSI
  1491. help
  1492. This will enable 10MHz FAST-SCSI transfers with your host
  1493. adapter. Some systems have problems with that speed, so it's safest
  1494. to say N here.
  1495. config SUN3_SCSI
  1496. tristate "Sun3 NCR5380 SCSI"
  1497. depends on SUN3 && SCSI && BROKEN
  1498. select SCSI_SPI_ATTRS
  1499. help
  1500. This option will enable support for the OBIO (onboard io) NCR5380
  1501. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1502. "Sun3" type VME scsi controllers also based on the NCR5380.
  1503. General Linux information on the Sun 3 series (now discontinued)
  1504. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1505. config SUN3X_ESP
  1506. bool "Sun3x ESP SCSI"
  1507. depends on SUN3X && SCSI=y
  1508. help
  1509. The ESP was an on-board SCSI controller used on Sun 3/80
  1510. machines. Say Y here to compile in support for it.
  1511. config SCSI_SUNESP
  1512. tristate "Sparc ESP Scsi Driver"
  1513. depends on SBUS && SCSI
  1514. help
  1515. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1516. chipset is present in most SPARC SBUS-based computers.
  1517. To compile this driver as a module, choose M here: the
  1518. module will be called esp.
  1519. # bool 'Cyberstorm Mk III SCSI support (EXPERIMENTAL)' CONFIG_CYBERSTORMIII_SCSI
  1520. config ZFCP
  1521. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1522. depends on S390 && QDIO && SCSI
  1523. select SCSI_FC_ATTRS
  1524. help
  1525. If you want to access SCSI devices attached to your IBM eServer
  1526. zSeries by means of Fibre Channel interfaces say Y.
  1527. For details please refer to the documentation provided by IBM at
  1528. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1529. This driver is also available as a module. This module will be
  1530. called zfcp. If you want to compile it as a module, say M here
  1531. and read <file:Documentation/modules.txt>.
  1532. endmenu
  1533. source "drivers/scsi/pcmcia/Kconfig"
  1534. endmenu