Kconfig 66 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802
  1. menu "SCSI device support"
  2. config RAID_ATTRS
  3. tristate "RAID Transport Class"
  4. default n
  5. ---help---
  6. Provides RAID
  7. config SCSI
  8. tristate "SCSI device support"
  9. ---help---
  10. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  11. any other SCSI device under Linux, say Y and make sure that you know
  12. the name of your SCSI host adapter (the card inside your computer
  13. that "speaks" the SCSI protocol, also called SCSI controller),
  14. because you will be asked for it.
  15. You also need to say Y here if you have a device which speaks
  16. the SCSI protocol. Examples of this include the parallel port
  17. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  18. Channel, FireWire storage and the IDE-SCSI emulation driver.
  19. To compile this driver as a module, choose M here and read
  20. <file:Documentation/scsi/scsi.txt>.
  21. The module will be called scsi_mod.
  22. However, do not compile this as a module if your root file system
  23. (the one containing the directory /) is located on a SCSI device.
  24. config SCSI_PROC_FS
  25. bool "legacy /proc/scsi/ support"
  26. depends on SCSI && PROC_FS
  27. default y
  28. ---help---
  29. This option enables support for the various files in
  30. /proc/scsi. In Linux 2.6 this has been superceeded by
  31. files in sysfs but many legacy applications rely on this.
  32. If unusure say Y.
  33. comment "SCSI support type (disk, tape, CD-ROM)"
  34. depends on SCSI
  35. config BLK_DEV_SD
  36. tristate "SCSI disk support"
  37. depends on SCSI
  38. ---help---
  39. If you want to use SCSI hard disks, Fibre Channel disks,
  40. USB storage or the SCSI or parallel port version of
  41. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  42. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  43. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  44. CD-ROMs.
  45. To compile this driver as a module, choose M here and read
  46. <file:Documentation/scsi/scsi.txt>.
  47. The module will be called sd_mod.
  48. Do not compile this driver as a module if your root file system
  49. (the one containing the directory /) is located on a SCSI disk.
  50. In this case, do not compile the driver for your SCSI host adapter
  51. (below) as a module either.
  52. config CHR_DEV_ST
  53. tristate "SCSI tape support"
  54. depends on SCSI
  55. ---help---
  56. If you want to use a SCSI tape drive under Linux, say Y and read the
  57. SCSI-HOWTO, available from
  58. <http://www.tldp.org/docs.html#howto>, and
  59. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  60. for SCSI CD-ROMs.
  61. To compile this driver as a module, choose M here and read
  62. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  63. config CHR_DEV_OSST
  64. tristate "SCSI OnStream SC-x0 tape support"
  65. depends on SCSI
  66. ---help---
  67. The OnStream SC-x0 SCSI tape drives can not be driven by the
  68. standard st driver, but instead need this special osst driver and
  69. use the /dev/osstX char device nodes (major 206). Via usb-storage
  70. and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
  71. as well. Note that there is also a second generation of OnStream
  72. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  73. tapes (QIC-157) and can be driven by the standard driver st.
  74. For more information, you may have a look at the SCSI-HOWTO
  75. <http://www.tldp.org/docs.html#howto> and
  76. <file:Documentation/scsi/osst.txt> in the kernel source.
  77. More info on the OnStream driver may be found on
  78. <http://linux1.onstream.nl/test/>
  79. Please also have a look at the standard st docu, as most of it
  80. applies to osst as well.
  81. To compile this driver as a module, choose M here and read
  82. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  83. config BLK_DEV_SR
  84. tristate "SCSI CDROM support"
  85. depends on SCSI
  86. ---help---
  87. If you want to use a SCSI or FireWire CD-ROM under Linux,
  88. say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
  89. <http://www.tldp.org/docs.html#howto>. Also make sure to say
  90. Y or M to "ISO 9660 CD-ROM file system support" later.
  91. To compile this driver as a module, choose M here and read
  92. <file:Documentation/scsi/scsi.txt>.
  93. The module will be called sr_mod.
  94. config BLK_DEV_SR_VENDOR
  95. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  96. depends on BLK_DEV_SR
  97. help
  98. This enables the usage of vendor specific SCSI commands. This is
  99. required to support multisession CDs with old NEC/TOSHIBA cdrom
  100. drives (and HP Writers). If you have such a drive and get the first
  101. session only, try saying Y here; everybody else says N.
  102. config CHR_DEV_SG
  103. tristate "SCSI generic support"
  104. depends on SCSI
  105. ---help---
  106. If you want to use SCSI scanners, synthesizers or CD-writers or just
  107. about anything having "SCSI" in its name other than hard disks,
  108. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  109. directly, so you need some additional software which knows how to
  110. talk to these devices using the SCSI protocol:
  111. For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
  112. writer software look at Cdrtools
  113. (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
  114. and for burning a "disk at once": CDRDAO
  115. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  116. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  117. For other devices, it's possible that you'll have to write the
  118. driver software yourself. Please read the file
  119. <file:Documentation/scsi/scsi-generic.txt> for more information.
  120. To compile this driver as a module, choose M here and read
  121. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  122. If unsure, say N.
  123. config CHR_DEV_SCH
  124. tristate "SCSI media changer support"
  125. depends on SCSI
  126. ---help---
  127. This is a driver for SCSI media changers. Most common devices are
  128. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  129. don't need this for those tiny 6-slot cdrom changers. Media
  130. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  131. If you have such hardware and want to use it with linux, say Y
  132. here. Check <file:Documentation/scsi-changer.txt> for details.
  133. If you want to compile this as a module ( = code which can be
  134. inserted in and removed from the running kernel whenever you want),
  135. say M here and read <file:Documentation/modules.txt> and
  136. <file:Documentation/scsi.txt>. The module will be called ch.o.
  137. If unsure, say N.
  138. comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
  139. depends on SCSI
  140. config SCSI_MULTI_LUN
  141. bool "Probe all LUNs on each SCSI device"
  142. depends on SCSI
  143. help
  144. If you have a SCSI device that supports more than one LUN (Logical
  145. Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
  146. can say Y here to force the SCSI driver to probe for multiple LUNs.
  147. A SCSI device with multiple LUNs acts logically like multiple SCSI
  148. devices. The vast majority of SCSI devices have only one LUN, and
  149. so most people can say N here. The max_luns boot/module parameter
  150. allows to override this setting.
  151. config SCSI_CONSTANTS
  152. bool "Verbose SCSI error reporting (kernel size +=12K)"
  153. depends on SCSI
  154. help
  155. The error messages regarding your SCSI hardware will be easier to
  156. understand if you say Y here; it will enlarge your kernel by about
  157. 12 KB. If in doubt, say Y.
  158. config SCSI_LOGGING
  159. bool "SCSI logging facility"
  160. depends on SCSI
  161. ---help---
  162. This turns on a logging facility that can be used to debug a number
  163. of SCSI related problems.
  164. If you say Y here, no logging output will appear by default, but you
  165. can enable logging by saying Y to "/proc file system support" and
  166. "Sysctl support" below and executing the command
  167. echo "scsi log token [level]" > /proc/scsi/scsi
  168. at boot time after the /proc file system has been mounted.
  169. There are a number of things that can be used for 'token' (you can
  170. find them in the source: <file:drivers/scsi/scsi.c>), and this
  171. allows you to select the types of information you want, and the
  172. level allows you to select the level of verbosity.
  173. If you say N here, it may be harder to track down some types of SCSI
  174. problems. If you say Y here your kernel will be somewhat larger, but
  175. there should be no noticeable performance impact as long as you have
  176. logging turned off.
  177. menu "SCSI Transport Attributes"
  178. depends on SCSI
  179. config SCSI_SPI_ATTRS
  180. tristate "Parallel SCSI (SPI) Transport Attributes"
  181. depends on SCSI
  182. help
  183. If you wish to export transport-specific information about
  184. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  185. config SCSI_FC_ATTRS
  186. tristate "FiberChannel Transport Attributes"
  187. depends on SCSI
  188. help
  189. If you wish to export transport-specific information about
  190. each attached FiberChannel device to sysfs, say Y.
  191. Otherwise, say N.
  192. config SCSI_ISCSI_ATTRS
  193. tristate "iSCSI Transport Attributes"
  194. depends on SCSI
  195. help
  196. If you wish to export transport-specific information about
  197. each attached iSCSI device to sysfs, say Y.
  198. Otherwise, say N.
  199. endmenu
  200. menu "SCSI low-level drivers"
  201. depends on SCSI!=n
  202. config SGIWD93_SCSI
  203. tristate "SGI WD93C93 SCSI Driver"
  204. depends on SGI_IP22 && SCSI
  205. help
  206. If you have a Western Digital WD93 SCSI controller on
  207. an SGI MIPS system, say Y. Otherwise, say N.
  208. config SCSI_DECNCR
  209. tristate "DEC NCR53C94 Scsi Driver"
  210. depends on MACH_DECSTATION && SCSI && TC
  211. help
  212. Say Y here to support the NCR53C94 SCSI controller chips on IOASIC
  213. based TURBOchannel DECstations and TURBOchannel PMAZ-A cards.
  214. config SCSI_DECSII
  215. tristate "DEC SII Scsi Driver"
  216. depends on MACH_DECSTATION && SCSI && MIPS32
  217. config BLK_DEV_3W_XXXX_RAID
  218. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  219. depends on PCI && SCSI
  220. help
  221. 3ware is the only hardware ATA-Raid product in Linux to date.
  222. This card is 2,4, or 8 channel master mode support only.
  223. SCSI support required!!!
  224. <http://www.3ware.com/>
  225. Please read the comments at the top of
  226. <file:drivers/scsi/3w-xxxx.c>.
  227. config SCSI_3W_9XXX
  228. tristate "3ware 9xxx SATA-RAID support"
  229. depends on PCI && SCSI
  230. help
  231. This driver supports the 9000 series 3ware SATA-RAID cards.
  232. <http://www.amcc.com>
  233. Please read the comments at the top of
  234. <file:drivers/scsi/3w-9xxx.c>.
  235. config SCSI_7000FASST
  236. tristate "7000FASST SCSI support"
  237. depends on ISA && SCSI && ISA_DMA_API
  238. help
  239. This driver supports the Western Digital 7000 SCSI host adapter
  240. family. Some information is in the source:
  241. <file:drivers/scsi/wd7000.c>.
  242. To compile this driver as a module, choose M here: the
  243. module will be called wd7000.
  244. config SCSI_ACARD
  245. tristate "ACARD SCSI support"
  246. depends on PCI && SCSI
  247. help
  248. This driver supports the ACARD SCSI host adapter.
  249. Support Chip <ATP870 ATP876 ATP880 ATP885>
  250. To compile this driver as a module, choose M here: the
  251. module will be called atp870u.
  252. config SCSI_AHA152X
  253. tristate "Adaptec AHA152X/2825 support"
  254. depends on ISA && SCSI && !64BIT
  255. ---help---
  256. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  257. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  258. must be manually specified in this case.
  259. It is explained in section 3.3 of the SCSI-HOWTO, available from
  260. <http://www.tldp.org/docs.html#howto>. You might also want to
  261. read the file <file:Documentation/scsi/aha152x.txt>.
  262. To compile this driver as a module, choose M here: the
  263. module will be called aha152x.
  264. config SCSI_AHA1542
  265. tristate "Adaptec AHA1542 support"
  266. depends on ISA && SCSI && ISA_DMA_API
  267. ---help---
  268. This is support for a SCSI host adapter. It is explained in section
  269. 3.4 of the SCSI-HOWTO, available from
  270. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  271. purchased by Adaptec, and some former Trantor products are being
  272. sold under the Adaptec name. If it doesn't work out of the box, you
  273. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  274. To compile this driver as a module, choose M here: the
  275. module will be called aha1542.
  276. config SCSI_AHA1740
  277. tristate "Adaptec AHA1740 support"
  278. depends on EISA && SCSI
  279. ---help---
  280. This is support for a SCSI host adapter. It is explained in section
  281. 3.5 of the SCSI-HOWTO, available from
  282. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  283. of the box, you may have to change some settings in
  284. <file:drivers/scsi/aha1740.h>.
  285. To compile this driver as a module, choose M here: the
  286. module will be called aha1740.
  287. config SCSI_AACRAID
  288. tristate "Adaptec AACRAID support"
  289. depends on SCSI && PCI
  290. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  291. config SCSI_AIC7XXX_OLD
  292. tristate "Adaptec AIC7xxx support (old driver)"
  293. depends on (ISA || EISA || PCI ) && SCSI
  294. help
  295. WARNING This driver is an older aic7xxx driver and is no longer
  296. under active development. Adaptec, Inc. is writing a new driver to
  297. take the place of this one, and it is recommended that whenever
  298. possible, people should use the new Adaptec written driver instead
  299. of this one. This driver will eventually be phased out entirely.
  300. This is support for the various aic7xxx based Adaptec SCSI
  301. controllers. These include the 274x EISA cards; 284x VLB cards;
  302. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  303. motherboard based SCSI controllers from Adaptec. It does not support
  304. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  305. support them. It does not support the 2920 cards from Adaptec that
  306. use the Future Domain SCSI controller chip. For those cards, you
  307. need the "Future Domain 16xx SCSI support" driver.
  308. In general, if the controller is based on an Adaptec SCSI controller
  309. chip from the aic777x series or the aic78xx series, this driver
  310. should work. The only exception is the 7810 which is specifically
  311. not supported (that's the RAID controller chip on the AAA-13x
  312. cards).
  313. Note that the AHA2920 SCSI host adapter is *not* supported by this
  314. driver; choose "Future Domain 16xx SCSI support" instead if you have
  315. one of those.
  316. Information on the configuration options for this controller can be
  317. found by checking the help file for each of the available
  318. configuration options. You should read
  319. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  320. contacting the maintainer with any questions. The SCSI-HOWTO,
  321. available from <http://www.tldp.org/docs.html#howto>, can also
  322. be of great help.
  323. To compile this driver as a module, choose M here: the
  324. module will be called aic7xxx_old.
  325. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  326. # All the I2O code and drivers do not seem to be 64bit safe.
  327. config SCSI_DPT_I2O
  328. tristate "Adaptec I2O RAID support "
  329. depends on !64BIT && SCSI && PCI
  330. help
  331. This driver supports all of Adaptec's I2O based RAID controllers as
  332. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  333. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  334. To compile this driver as a module, choose M here: the
  335. module will be called dpt_i2o.
  336. config SCSI_ADVANSYS
  337. tristate "AdvanSys SCSI support"
  338. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  339. help
  340. This is a driver for all SCSI host adapters manufactured by
  341. AdvanSys. It is documented in the kernel source in
  342. <file:drivers/scsi/advansys.c>.
  343. To compile this driver as a module, choose M here: the
  344. module will be called advansys.
  345. config SCSI_IN2000
  346. tristate "Always IN2000 SCSI support"
  347. depends on ISA && SCSI
  348. help
  349. This is support for an ISA bus SCSI host adapter. You'll find more
  350. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  351. out of the box, you may have to change the jumpers for IRQ or
  352. address selection.
  353. To compile this driver as a module, choose M here: the
  354. module will be called in2000.
  355. source "drivers/scsi/megaraid/Kconfig.megaraid"
  356. config SCSI_SATA
  357. bool "Serial ATA (SATA) support"
  358. depends on SCSI
  359. help
  360. This driver family supports Serial ATA host controllers
  361. and devices.
  362. If unsure, say N.
  363. config SCSI_SATA_AHCI
  364. tristate "AHCI SATA support"
  365. depends on SCSI_SATA && PCI
  366. help
  367. This option enables support for AHCI Serial ATA.
  368. If unsure, say N.
  369. config SCSI_SATA_SVW
  370. tristate "ServerWorks Frodo / Apple K2 SATA support"
  371. depends on SCSI_SATA && PCI
  372. help
  373. This option enables support for Broadcom/Serverworks/Apple K2
  374. SATA support.
  375. If unsure, say N.
  376. config SCSI_ATA_PIIX
  377. tristate "Intel PIIX/ICH SATA support"
  378. depends on SCSI_SATA && PCI
  379. help
  380. This option enables support for ICH5 Serial ATA.
  381. If PATA support was enabled previously, this enables
  382. support for select Intel PIIX/ICH PATA host controllers.
  383. If unsure, say N.
  384. config SCSI_SATA_NV
  385. tristate "NVIDIA SATA support"
  386. depends on SCSI_SATA && PCI && EXPERIMENTAL
  387. help
  388. This option enables support for NVIDIA Serial ATA.
  389. If unsure, say N.
  390. config SCSI_SATA_PROMISE
  391. tristate "Promise SATA TX2/TX4 support"
  392. depends on SCSI_SATA && PCI
  393. help
  394. This option enables support for Promise Serial ATA TX2/TX4.
  395. If unsure, say N.
  396. config SCSI_SATA_QSTOR
  397. tristate "Pacific Digital SATA QStor support"
  398. depends on SCSI_SATA && PCI
  399. help
  400. This option enables support for Pacific Digital Serial ATA QStor.
  401. If unsure, say N.
  402. config SCSI_SATA_SX4
  403. tristate "Promise SATA SX4 support"
  404. depends on SCSI_SATA && PCI && EXPERIMENTAL
  405. help
  406. This option enables support for Promise Serial ATA SX4.
  407. If unsure, say N.
  408. config SCSI_SATA_SIL
  409. tristate "Silicon Image SATA support"
  410. depends on SCSI_SATA && PCI && EXPERIMENTAL
  411. help
  412. This option enables support for Silicon Image Serial ATA.
  413. If unsure, say N.
  414. config SCSI_SATA_SIS
  415. tristate "SiS 964/180 SATA support"
  416. depends on SCSI_SATA && PCI && EXPERIMENTAL
  417. help
  418. This option enables support for SiS Serial ATA 964/180.
  419. If unsure, say N.
  420. config SCSI_SATA_ULI
  421. tristate "ULi Electronics SATA support"
  422. depends on SCSI_SATA && PCI && EXPERIMENTAL
  423. help
  424. This option enables support for ULi Electronics SATA.
  425. If unsure, say N.
  426. config SCSI_SATA_VIA
  427. tristate "VIA SATA support"
  428. depends on SCSI_SATA && PCI
  429. help
  430. This option enables support for VIA Serial ATA.
  431. If unsure, say N.
  432. config SCSI_SATA_VITESSE
  433. tristate "VITESSE VSC-7174 SATA support"
  434. depends on SCSI_SATA && PCI
  435. help
  436. This option enables support for Vitesse VSC7174 Serial ATA.
  437. If unsure, say N.
  438. config SCSI_BUSLOGIC
  439. tristate "BusLogic SCSI support"
  440. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API
  441. ---help---
  442. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  443. Adapters. Consult the SCSI-HOWTO, available from
  444. <http://www.tldp.org/docs.html#howto>, and the files
  445. <file:Documentation/scsi/BusLogic.txt> and
  446. <file:Documentation/scsi/FlashPoint.txt> for more information.
  447. To compile this driver as a module, choose M here: the
  448. module will be called BusLogic.
  449. config SCSI_OMIT_FLASHPOINT
  450. bool "Omit FlashPoint support"
  451. depends on SCSI_BUSLOGIC
  452. help
  453. This option allows you to omit the FlashPoint support from the
  454. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  455. substantial, so users of MultiMaster Host Adapters may wish to omit
  456. it.
  457. #
  458. # This is marked broken because it uses over 4kB of stack in
  459. # just two routines:
  460. # 2076 CpqTsProcessIMQEntry
  461. # 2052 PeekIMQEntry
  462. #
  463. config SCSI_CPQFCTS
  464. tristate "Compaq Fibre Channel 64-bit/66Mhz HBA support"
  465. depends on PCI && SCSI && BROKEN
  466. help
  467. Say Y here to compile in support for the Compaq StorageWorks Fibre
  468. Channel 64-bit/66Mhz Host Bus Adapter.
  469. config SCSI_DMX3191D
  470. tristate "DMX3191D SCSI support"
  471. depends on PCI && SCSI
  472. help
  473. This is support for Domex DMX3191D SCSI Host Adapters.
  474. To compile this driver as a module, choose M here: the
  475. module will be called dmx3191d.
  476. config SCSI_DTC3280
  477. tristate "DTC3180/3280 SCSI support"
  478. depends on ISA && SCSI
  479. help
  480. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  481. the SCSI-HOWTO, available from
  482. <http://www.tldp.org/docs.html#howto>, and the file
  483. <file:Documentation/scsi/dtc3x80.txt>.
  484. To compile this driver as a module, choose M here: the
  485. module will be called dtc.
  486. config SCSI_EATA
  487. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  488. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  489. ---help---
  490. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  491. ISA and all EISA I/O addresses are probed looking for the "EATA"
  492. signature. The addresses of all the PCI SCSI controllers reported
  493. by the PCI subsystem are probed as well.
  494. You want to read the start of <file:drivers/scsi/eata.c> and the
  495. SCSI-HOWTO, available from
  496. <http://www.tldp.org/docs.html#howto>.
  497. To compile this driver as a module, choose M here: the
  498. module will be called eata.
  499. config SCSI_EATA_TAGGED_QUEUE
  500. bool "enable tagged command queueing"
  501. depends on SCSI_EATA
  502. help
  503. This is a feature of SCSI-2 which improves performance: the host
  504. adapter can send several SCSI commands to a device's queue even if
  505. previous commands haven't finished yet.
  506. This is equivalent to the "eata=tc:y" boot option.
  507. config SCSI_EATA_LINKED_COMMANDS
  508. bool "enable elevator sorting"
  509. depends on SCSI_EATA
  510. help
  511. This option enables elevator sorting for all probed SCSI disks and
  512. CD-ROMs. It definitely reduces the average seek distance when doing
  513. random seeks, but this does not necessarily result in a noticeable
  514. performance improvement: your mileage may vary...
  515. This is equivalent to the "eata=lc:y" boot option.
  516. config SCSI_EATA_MAX_TAGS
  517. int "maximum number of queued commands"
  518. depends on SCSI_EATA
  519. default "16"
  520. help
  521. This specifies how many SCSI commands can be maximally queued for
  522. each probed SCSI device. You should reduce the default value of 16
  523. only if you have disks with buggy or limited tagged command support.
  524. Minimum is 2 and maximum is 62. This value is also the window size
  525. used by the elevator sorting option above. The effective value used
  526. by the driver for each probed SCSI device is reported at boot time.
  527. This is equivalent to the "eata=mq:8" boot option.
  528. config SCSI_EATA_PIO
  529. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  530. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  531. ---help---
  532. This driver supports all EATA-PIO protocol compliant SCSI Host
  533. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  534. host adapters could also use this driver but are discouraged from
  535. doing so, since this driver only supports hard disks and lacks
  536. numerous features. You might want to have a look at the SCSI-HOWTO,
  537. available from <http://www.tldp.org/docs.html#howto>.
  538. To compile this driver as a module, choose M here: the
  539. module will be called eata_pio.
  540. config SCSI_FUTURE_DOMAIN
  541. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  542. depends on (ISA || PCI) && SCSI
  543. ---help---
  544. This is support for Future Domain's 16-bit SCSI host adapters
  545. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  546. other adapters based on the Future Domain chipsets (Quantum
  547. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  548. It is explained in section 3.7 of the SCSI-HOWTO, available from
  549. <http://www.tldp.org/docs.html#howto>.
  550. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  551. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  552. controller support"). This Future Domain driver works with the older
  553. Adaptec AHA-2920A boards with a Future Domain chip on them.
  554. To compile this driver as a module, choose M here: the
  555. module will be called fdomain.
  556. config SCSI_FD_MCS
  557. tristate "Future Domain MCS-600/700 SCSI support"
  558. depends on MCA_LEGACY && SCSI
  559. ---help---
  560. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  561. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  562. is identical to the MCS 700 and hence also supported by this driver.
  563. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  564. It supports multiple adapters in the same system.
  565. To compile this driver as a module, choose M here: the
  566. module will be called fd_mcs.
  567. config SCSI_GDTH
  568. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  569. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  570. ---help---
  571. Formerly called GDT SCSI Disk Array Controller Support.
  572. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  573. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  574. in the kernel source in <file:drivers/scsi/gdth.c> and
  575. <file:drivers/scsi/gdth.h.>
  576. To compile this driver as a module, choose M here: the
  577. module will be called gdth.
  578. config SCSI_GENERIC_NCR5380
  579. tristate "Generic NCR5380/53c400 SCSI PIO support"
  580. depends on ISA && SCSI
  581. ---help---
  582. This is a driver for the old NCR 53c80 series of SCSI controllers
  583. on boards using PIO. Most boards such as the Trantor T130 fit this
  584. category, along with a large number of ISA 8bit controllers shipped
  585. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  586. you should select the specific driver for that card rather than
  587. generic 5380 support.
  588. It is explained in section 3.8 of the SCSI-HOWTO, available from
  589. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  590. of the box, you may have to change some settings in
  591. <file:drivers/scsi/g_NCR5380.h>.
  592. To compile this driver as a module, choose M here: the
  593. module will be called g_NCR5380.
  594. config SCSI_GENERIC_NCR5380_MMIO
  595. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  596. depends on ISA && SCSI
  597. ---help---
  598. This is a driver for the old NCR 53c80 series of SCSI controllers
  599. on boards using memory mapped I/O.
  600. It is explained in section 3.8 of the SCSI-HOWTO, available from
  601. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  602. of the box, you may have to change some settings in
  603. <file:drivers/scsi/g_NCR5380.h>.
  604. To compile this driver as a module, choose M here: the
  605. module will be called g_NCR5380_mmio.
  606. config SCSI_GENERIC_NCR53C400
  607. bool "Enable NCR53c400 extensions"
  608. depends on SCSI_GENERIC_NCR5380
  609. help
  610. This enables certain optimizations for the NCR53c400 SCSI cards.
  611. You might as well try it out. Note that this driver will only probe
  612. for the Trantor T130B in its default configuration; you might have
  613. to pass a command line option to the kernel at boot time if it does
  614. not detect your card. See the file
  615. <file:Documentation/scsi/g_NCR5380.txt> for details.
  616. config SCSI_IBMMCA
  617. tristate "IBMMCA SCSI support"
  618. depends on MCA_LEGACY && SCSI
  619. ---help---
  620. This is support for the IBM SCSI adapter found in many of the PS/2
  621. series computers. These machines have an MCA bus, so you need to
  622. answer Y to "MCA support" as well and read
  623. <file:Documentation/mca.txt>.
  624. If the adapter isn't found during boot (a common problem for models
  625. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  626. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  627. if that doesn't work check your reference diskette). Owners of
  628. model 95 with a LED-matrix-display can in addition activate some
  629. activity info like under OS/2, but more informative, by setting
  630. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  631. bootparam" or see the documentation of your boot loader about how to
  632. pass options to the kernel.
  633. To compile this driver as a module, choose M here: the
  634. module will be called ibmmca.
  635. config IBMMCA_SCSI_ORDER_STANDARD
  636. bool "Standard SCSI-order"
  637. depends on SCSI_IBMMCA
  638. ---help---
  639. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  640. are assigned to the drive letters, starting with the lowest SCSI-id
  641. (physical number -- pun) to be drive C:, as seen from DOS and
  642. similar operating systems. When looking into papers describing the
  643. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  644. The SCSI-standard follows a hardware-hierarchy which says that id 7
  645. has the highest priority and id 0 the lowest. Therefore, the host
  646. adapters are still today everywhere placed as SCSI-id 7 by default.
  647. In the SCSI-standard, the drive letters express the priority of the
  648. disk. C: should be the hard disk, or a partition on it, with the
  649. highest priority. This must therefore be the disk with the highest
  650. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  651. original definition of the SCSI-standard as also industrial- and
  652. process-control-machines, like VME-CPUs running under realtime-OSes
  653. (e.g. LynxOS, OS9) do.
  654. If you like to run Linux on your MCA-machine with the same
  655. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  656. machine, which is in addition conformant to the SCSI-standard, you
  657. must say Y here. This is also necessary for MCA-Linux users who want
  658. to keep downward compatibility to older releases of the
  659. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  660. June 1997).
  661. If you like to have the lowest SCSI-id assigned as drive C:, as
  662. modern SCSI-BIOSes do, which does not conform to the standard, but
  663. is widespread and common in the PC-world of today, you must say N
  664. here. If unsure, say Y.
  665. config IBMMCA_SCSI_DEV_RESET
  666. bool "Reset SCSI-devices at boottime"
  667. depends on SCSI_IBMMCA
  668. ---help---
  669. By default, SCSI-devices are reset when the machine is powered on.
  670. However, some devices exist, like special-control-devices,
  671. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  672. not reset when switched on. If you say Y here, each device connected
  673. to your SCSI-bus will be issued a reset-command after it has been
  674. probed, while the kernel is booting. This may cause problems with
  675. more modern devices, like hard disks, which do not appreciate these
  676. reset commands, and can cause your system to hang. So say Y only if
  677. you know that one of your older devices needs it; N is the safe
  678. answer.
  679. config SCSI_IPS
  680. tristate "IBM ServeRAID support"
  681. depends on PCI && SCSI
  682. ---help---
  683. This is support for the IBM ServeRAID hardware RAID controllers.
  684. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  685. for more information. If this driver does not work correctly
  686. without modification please contact the author by email at
  687. <ipslinux@adaptec.com>.
  688. To compile this driver as a module, choose M here: the
  689. module will be called ips.
  690. config SCSI_IBMVSCSI
  691. tristate "IBM Virtual SCSI support"
  692. depends on PPC_PSERIES || PPC_ISERIES
  693. help
  694. This is the IBM POWER Virtual SCSI Client
  695. To compile this driver as a module, choose M here: the
  696. module will be called ibmvscsic.
  697. config SCSI_INITIO
  698. tristate "Initio 9100U(W) support"
  699. depends on PCI && SCSI
  700. help
  701. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  702. read the SCSI-HOWTO, available from
  703. <http://www.tldp.org/docs.html#howto>.
  704. To compile this driver as a module, choose M here: the
  705. module will be called initio.
  706. config SCSI_INIA100
  707. tristate "Initio INI-A100U2W support"
  708. depends on PCI && SCSI
  709. help
  710. This is support for the Initio INI-A100U2W SCSI host adapter.
  711. Please read the SCSI-HOWTO, available from
  712. <http://www.tldp.org/docs.html#howto>.
  713. To compile this driver as a module, choose M here: the
  714. module will be called a100u2w.
  715. config SCSI_PPA
  716. tristate "IOMEGA parallel port (ppa - older drives)"
  717. depends on SCSI && PARPORT
  718. ---help---
  719. This driver supports older versions of IOMEGA's parallel port ZIP
  720. drive (a 100 MB removable media device).
  721. Note that you can say N here if you have the SCSI version of the ZIP
  722. drive: it will be supported automatically if you said Y to the
  723. generic "SCSI disk support", above.
  724. If you have the ZIP Plus drive or a more recent parallel port ZIP
  725. drive (if the supplied cable with the drive is labeled "AutoDetect")
  726. then you should say N here and Y to "IOMEGA parallel port (imm -
  727. newer drives)", below.
  728. For more information about this driver and how to use it you should
  729. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  730. the SCSI-HOWTO, which is available from
  731. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  732. you will still be able to use the parallel port for other tasks,
  733. such as a printer; it is safe to compile both drivers into the
  734. kernel.
  735. To compile this driver as a module, choose M here: the
  736. module will be called ppa.
  737. config SCSI_IMM
  738. tristate "IOMEGA parallel port (imm - newer drives)"
  739. depends on SCSI && PARPORT
  740. ---help---
  741. This driver supports newer versions of IOMEGA's parallel port ZIP
  742. drive (a 100 MB removable media device).
  743. Note that you can say N here if you have the SCSI version of the ZIP
  744. drive: it will be supported automatically if you said Y to the
  745. generic "SCSI disk support", above.
  746. If you have the ZIP Plus drive or a more recent parallel port ZIP
  747. drive (if the supplied cable with the drive is labeled "AutoDetect")
  748. then you should say Y here; if you have an older ZIP drive, say N
  749. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  750. For more information about this driver and how to use it you should
  751. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  752. the SCSI-HOWTO, which is available from
  753. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  754. you will still be able to use the parallel port for other tasks,
  755. such as a printer; it is safe to compile both drivers into the
  756. kernel.
  757. To compile this driver as a module, choose M here: the
  758. module will be called imm.
  759. config SCSI_IZIP_EPP16
  760. bool "ppa/imm option - Use slow (but safe) EPP-16"
  761. depends on PARPORT && (SCSI_PPA || SCSI_IMM)
  762. ---help---
  763. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  764. allows them to act as expansion buses that can handle up to 64
  765. peripheral devices.
  766. Some parallel port chipsets are slower than their motherboard, and
  767. so we have to control the state of the chipset's FIFO queue every
  768. now and then to avoid data loss. This will be done if you say Y
  769. here.
  770. Generally, saying Y is the safe option and slows things down a bit.
  771. config SCSI_IZIP_SLOW_CTR
  772. bool "ppa/imm option - Assume slow parport control register"
  773. depends on PARPORT && (SCSI_PPA || SCSI_IMM)
  774. help
  775. Some parallel ports are known to have excessive delays between
  776. changing the parallel port control register and good data being
  777. available on the parallel port data/status register. This option
  778. forces a small delay (1.0 usec to be exact) after changing the
  779. control register to let things settle out. Enabling this option may
  780. result in a big drop in performance but some very old parallel ports
  781. (found in 386 vintage machines) will not work properly.
  782. Generally, saying N is fine.
  783. config SCSI_NCR53C406A
  784. tristate "NCR53c406a SCSI support"
  785. depends on ISA && SCSI
  786. help
  787. This is support for the NCR53c406a SCSI host adapter. For user
  788. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  789. in the kernel source. Also read the SCSI-HOWTO, available from
  790. <http://www.tldp.org/docs.html#howto>.
  791. To compile this driver as a module, choose M here: the
  792. module will be called NCR53c406.
  793. config SCSI_NCR_D700
  794. tristate "NCR Dual 700 MCA SCSI support"
  795. depends on MCA && SCSI
  796. select SCSI_SPI_ATTRS
  797. help
  798. This is a driver for the MicroChannel Dual 700 card produced by
  799. NCR and commonly used in 345x/35xx/4100 class machines. It always
  800. tries to negotiate sync and uses tag command queueing.
  801. Unless you have an NCR manufactured machine, the chances are that
  802. you do not have this SCSI card, so say N.
  803. config SCSI_LASI700
  804. tristate "HP Lasi SCSI support for 53c700/710"
  805. depends on GSC && SCSI
  806. select SCSI_SPI_ATTRS
  807. help
  808. This is a driver for the SCSI controller in the Lasi chip found in
  809. many PA-RISC workstations & servers. If you do not know whether you
  810. have a Lasi chip, it is safe to say "Y" here.
  811. config 53C700_LE_ON_BE
  812. bool
  813. depends on SCSI_LASI700
  814. default y
  815. config SCSI_SYM53C8XX_2
  816. tristate "SYM53C8XX Version 2 SCSI support"
  817. depends on PCI && SCSI
  818. select SCSI_SPI_ATTRS
  819. ---help---
  820. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  821. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  822. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  823. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  824. controllers; you need to use the Fusion MPT driver for that.
  825. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  826. information.
  827. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  828. int "DMA addressing mode"
  829. depends on SCSI_SYM53C8XX_2
  830. default "1"
  831. ---help---
  832. This option only applies to PCI-SCSI chips that are PCI DAC
  833. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  834. When set to 0, the driver will program the chip to only perform
  835. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  836. to addresses up to 1TB. When set to 2, the driver supports the
  837. full 64-bit DMA address range, but can only address 16 segments
  838. of 4 GB each. This limits the total addressable range to 64 GB.
  839. Most machines with less than 4GB of memory should use a setting
  840. of 0 for best performance. If your machine has 4GB of memory
  841. or more, you should set this option to 1 (the default).
  842. The still experimental value 2 (64 bit DMA addressing with 16
  843. x 4GB segments limitation) can be used on systems that require
  844. PCI address bits past bit 39 to be set for the addressing of
  845. memory using PCI DAC cycles.
  846. config SCSI_SYM53C8XX_DEFAULT_TAGS
  847. int "default tagged command queue depth"
  848. depends on SCSI_SYM53C8XX_2
  849. default "16"
  850. help
  851. This is the default value of the command queue depth the
  852. driver will announce to the generic SCSI layer for devices
  853. that support tagged command queueing. This value can be changed
  854. from the boot command line. This is a soft limit that cannot
  855. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  856. config SCSI_SYM53C8XX_MAX_TAGS
  857. int "maximum number of queued commands"
  858. depends on SCSI_SYM53C8XX_2
  859. default "64"
  860. help
  861. This option allows you to specify the maximum number of commands
  862. that can be queued to any device, when tagged command queuing is
  863. possible. The driver supports up to 256 queued commands per device.
  864. This value is used as a compiled-in hard limit.
  865. config SCSI_SYM53C8XX_IOMAPPED
  866. bool "use port IO"
  867. depends on SCSI_SYM53C8XX_2
  868. help
  869. If you say Y here, the driver will use port IO to access
  870. the card. This is significantly slower then using memory
  871. mapped IO. Most people should answer N.
  872. config SCSI_IPR
  873. tristate "IBM Power Linux RAID adapter support"
  874. depends on PCI && SCSI
  875. select FW_LOADER
  876. ---help---
  877. This driver supports the IBM Power Linux family RAID adapters.
  878. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  879. as IBM iSeries 5702, 5703, 5709, and 570A.
  880. config SCSI_IPR_TRACE
  881. bool "enable driver internal trace"
  882. depends on SCSI_IPR
  883. help
  884. If you say Y here, the driver will trace all commands issued
  885. to the adapter. Performance impact is minimal. Trace can be
  886. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  887. config SCSI_IPR_DUMP
  888. bool "enable adapter dump support"
  889. depends on SCSI_IPR
  890. help
  891. If you say Y here, the driver will support adapter crash dump.
  892. If you enable this support, the iprdump daemon can be used
  893. to capture adapter failure analysis information.
  894. config SCSI_ZALON
  895. tristate "Zalon SCSI support"
  896. depends on GSC && SCSI
  897. select SCSI_SPI_ATTRS
  898. help
  899. The Zalon is a GSC/HSC bus interface chip that sits between the
  900. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  901. C110, J200, J210 and some D, K & R-class machines. It's also
  902. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  903. Say Y here if you have one of these machines or cards.
  904. config SCSI_NCR_Q720
  905. tristate "NCR Quad 720 MCA SCSI support"
  906. depends on MCA && SCSI
  907. select SCSI_SPI_ATTRS
  908. help
  909. This is a driver for the MicroChannel Quad 720 card produced by
  910. NCR and commonly used in 345x/35xx/4100 class machines. It always
  911. tries to negotiate sync and uses tag command queueing.
  912. Unless you have an NCR manufactured machine, the chances are that
  913. you do not have this SCSI card, so say N.
  914. config SCSI_NCR53C8XX_DEFAULT_TAGS
  915. int " default tagged command queue depth"
  916. depends on SCSI_ZALON || SCSI_NCR_Q720
  917. default "8"
  918. ---help---
  919. "Tagged command queuing" is a feature of SCSI-2 which improves
  920. performance: the host adapter can send several SCSI commands to a
  921. device's queue even if previous commands haven't finished yet.
  922. Because the device is intelligent, it can optimize its operations
  923. (like head positioning) based on its own request queue. Some SCSI
  924. devices don't implement this properly; if you want to disable this
  925. feature, enter 0 or 1 here (it doesn't matter which).
  926. The default value is 8 and should be supported by most hard disks.
  927. This value can be overridden from the boot command line using the
  928. 'tags' option as follows (example):
  929. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  930. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  931. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  932. The normal answer therefore is to go with the default 8 and to use
  933. a boot command line option for devices that need to use a different
  934. command queue depth.
  935. There is no safe option other than using good SCSI devices.
  936. config SCSI_NCR53C8XX_MAX_TAGS
  937. int " maximum number of queued commands"
  938. depends on SCSI_ZALON || SCSI_NCR_Q720
  939. default "32"
  940. ---help---
  941. This option allows you to specify the maximum number of commands
  942. that can be queued to any device, when tagged command queuing is
  943. possible. The default value is 32. Minimum is 2, maximum is 64.
  944. Modern hard disks are able to support 64 tags and even more, but
  945. do not seem to be faster when more than 32 tags are being used.
  946. So, the normal answer here is to go with the default value 32 unless
  947. you are using very large hard disks with large cache (>= 1 MB) that
  948. are able to take advantage of more than 32 tagged commands.
  949. There is no safe option and the default answer is recommended.
  950. config SCSI_NCR53C8XX_SYNC
  951. int " synchronous transfers frequency in MHz"
  952. depends on SCSI_ZALON || SCSI_NCR_Q720
  953. default "20"
  954. ---help---
  955. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  956. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  957. are respectively the maximum data transfer rates in mega-transfers
  958. per second for each class. For example, a FAST-20 Wide 16 device is
  959. able to transfer data at 20 million 16 bit packets per second for a
  960. total rate of 40 MB/s.
  961. You may specify 0 if you want to only use asynchronous data
  962. transfers. This is the safest and slowest option. Otherwise, specify
  963. a value between 5 and 80, depending on the capability of your SCSI
  964. controller. The higher the number, the faster the data transfer.
  965. Note that 80 should normally be ok since the driver decreases the
  966. value automatically according to the controller's capabilities.
  967. Your answer to this question is ignored for controllers with NVRAM,
  968. since the driver will get this information from the user set-up. It
  969. also can be overridden using a boot setup option, as follows
  970. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  971. for FAST-20 synchronous data transfer (20 mega-transfers per
  972. second).
  973. The normal answer therefore is not to go with the default but to
  974. select the maximum value 80 allowing the driver to use the maximum
  975. value supported by each controller. If this causes problems with
  976. your SCSI devices, you should come back and decrease the value.
  977. There is no safe option other than using good cabling, right
  978. terminations and SCSI conformant devices.
  979. config SCSI_NCR53C8XX_PROFILE
  980. bool " enable profiling"
  981. depends on SCSI_ZALON || SCSI_NCR_Q720
  982. help
  983. This option allows you to enable profiling information gathering.
  984. These statistics are not very accurate due to the low frequency
  985. of the kernel clock (100 Hz on i386) and have performance impact
  986. on systems that use very fast devices.
  987. The normal answer therefore is N.
  988. config SCSI_NCR53C8XX_NO_DISCONNECT
  989. bool " not allow targets to disconnect"
  990. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  991. help
  992. This option is only provided for safety if you suspect some SCSI
  993. device of yours to not support properly the target-disconnect
  994. feature. In that case, you would say Y here. In general however, to
  995. not allow targets to disconnect is not reasonable if there is more
  996. than 1 device on a SCSI bus. The normal answer therefore is N.
  997. config SCSI_MCA_53C9X
  998. tristate "NCR MCA 53C9x SCSI support"
  999. depends on MCA_LEGACY && SCSI && BROKEN_ON_SMP
  1000. help
  1001. Some MicroChannel machines, notably the NCR 35xx line, use a SCSI
  1002. controller based on the NCR 53C94. This driver will allow use of
  1003. the controller on the 3550, and very possibly others.
  1004. To compile this driver as a module, choose M here: the
  1005. module will be called mca_53c9x.
  1006. config SCSI_PAS16
  1007. tristate "PAS16 SCSI support"
  1008. depends on ISA && SCSI
  1009. ---help---
  1010. This is support for a SCSI host adapter. It is explained in section
  1011. 3.10 of the SCSI-HOWTO, available from
  1012. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1013. of the box, you may have to change some settings in
  1014. <file:drivers/scsi/pas16.h>.
  1015. To compile this driver as a module, choose M here: the
  1016. module will be called pas16.
  1017. config SCSI_PSI240I
  1018. tristate "PSI240i support"
  1019. depends on ISA && SCSI
  1020. help
  1021. This is support for the PSI240i EIDE interface card which acts as a
  1022. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1023. <http://www.tldp.org/docs.html#howto>.
  1024. To compile this driver as a module, choose M here: the
  1025. module will be called psi240i.
  1026. config SCSI_QLOGIC_FAS
  1027. tristate "Qlogic FAS SCSI support"
  1028. depends on ISA && SCSI
  1029. ---help---
  1030. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1031. FastSCSI! cards as well as any other card based on the FASXX chip
  1032. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1033. This driver does NOT support the PCI versions of these cards. The
  1034. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1035. SCSI support"), below.
  1036. Information about this driver is contained in
  1037. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1038. SCSI-HOWTO, available from
  1039. <http://www.tldp.org/docs.html#howto>.
  1040. To compile this driver as a module, choose M here: the
  1041. module will be called qlogicfas.
  1042. config SCSI_QLOGIC_ISP
  1043. tristate "Qlogic ISP SCSI support (old driver)"
  1044. depends on PCI && SCSI && BROKEN
  1045. ---help---
  1046. This driver works for all QLogic PCI SCSI host adapters (IQ-PCI,
  1047. IQ-PCI-10, IQ_PCI-D) except for the PCI-basic card. (This latter
  1048. card is supported by the "AM53/79C974 PCI SCSI" driver.)
  1049. If you say Y here, make sure to choose "BIOS" at the question "PCI
  1050. access mode".
  1051. Please read the file <file:Documentation/scsi/qlogicisp.txt>. You
  1052. should also read the SCSI-HOWTO, available from
  1053. <http://www.tldp.org/docs.html#howto>.
  1054. To compile this driver as a module, choose M here: the
  1055. module will be called qlogicisp.
  1056. These days the hardware is also supported by the more modern qla1280
  1057. driver. In doubt use that one instead of qlogicisp.
  1058. config SCSI_QLOGIC_FC
  1059. tristate "Qlogic ISP FC SCSI support"
  1060. depends on PCI && SCSI
  1061. help
  1062. This is a driver for the QLogic ISP2100 SCSI-FCP host adapter.
  1063. To compile this driver as a module, choose M here: the
  1064. module will be called qlogicfc.
  1065. config SCSI_QLOGIC_FC_FIRMWARE
  1066. bool "Include loadable firmware in driver"
  1067. depends on SCSI_QLOGIC_FC
  1068. help
  1069. Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
  1070. expanded LUN addressing and FcTape (FCP-2) support, in the
  1071. qlogicfc driver. This is required on some platforms.
  1072. config SCSI_QLOGIC_1280
  1073. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1074. depends on PCI && SCSI
  1075. help
  1076. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1077. To compile this driver as a module, choose M here: the
  1078. module will be called qla1280.
  1079. config SCSI_QLOGIC_1280_1040
  1080. bool "Qlogic QLA 1020/1040 SCSI support"
  1081. depends on SCSI_QLOGIC_1280 && SCSI_QLOGIC_ISP!=y
  1082. help
  1083. Say Y here if you have a QLogic ISP1020/1040 SCSI host adapter and
  1084. do not want to use the old driver. This option enables support in
  1085. the qla1280 driver for those host adapters.
  1086. config SCSI_QLOGICPTI
  1087. tristate "PTI Qlogic, ISP Driver"
  1088. depends on SBUS && SCSI
  1089. help
  1090. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1091. controllers are known under Solaris as qpti and in the openprom as
  1092. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1093. driven by a different driver.
  1094. To compile this driver as a module, choose M here: the
  1095. module will be called qlogicpti.
  1096. source "drivers/scsi/qla2xxx/Kconfig"
  1097. config SCSI_LPFC
  1098. tristate "Emulex LightPulse Fibre Channel Support"
  1099. depends on PCI && SCSI
  1100. select SCSI_FC_ATTRS
  1101. help
  1102. This lpfc driver supports the Emulex LightPulse
  1103. Family of Fibre Channel PCI host adapters.
  1104. config SCSI_SEAGATE
  1105. tristate "Seagate ST-02 and Future Domain TMC-8xx SCSI support"
  1106. depends on X86 && ISA && SCSI && BROKEN
  1107. ---help---
  1108. These are 8-bit SCSI controllers; the ST-01 is also supported by
  1109. this driver. It is explained in section 3.9 of the SCSI-HOWTO,
  1110. available from <http://www.tldp.org/docs.html#howto>. If it
  1111. doesn't work out of the box, you may have to change some settings in
  1112. <file:drivers/scsi/seagate.h>.
  1113. To compile this driver as a module, choose M here: the
  1114. module will be called seagate.
  1115. # definitely looks not 64bit safe:
  1116. config SCSI_SIM710
  1117. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1118. depends on (EISA || MCA) && SCSI
  1119. select SCSI_SPI_ATTRS
  1120. ---help---
  1121. This driver for NCR53c710 based SCSI host adapters.
  1122. It currently supports Compaq EISA cards and NCR MCA cards
  1123. config 53C700_IO_MAPPED
  1124. bool
  1125. depends on SCSI_SIM710
  1126. default y
  1127. config SCSI_SYM53C416
  1128. tristate "Symbios 53c416 SCSI support"
  1129. depends on ISA && SCSI
  1130. ---help---
  1131. This is support for the sym53c416 SCSI host adapter, the SCSI
  1132. adapter that comes with some HP scanners. This driver requires that
  1133. the sym53c416 is configured first using some sort of PnP
  1134. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1135. are using isapnp then you need to compile this driver as a module
  1136. and then load it using insmod after isapnp has run. The parameters
  1137. of the configured card(s) should be passed to the driver. The format
  1138. is:
  1139. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1140. To compile this driver as a module, choose M here: the
  1141. module will be called sym53c416.
  1142. config SCSI_DC395x
  1143. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1144. depends on PCI && SCSI && EXPERIMENTAL
  1145. ---help---
  1146. This driver supports PCI SCSI host adapters based on the ASIC
  1147. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1148. This driver works, but is still in experimental status. So better
  1149. have a bootable disk and a backup in case of emergency.
  1150. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1151. To compile this driver as a module, choose M here: the
  1152. module will be called dc395x.
  1153. config SCSI_DC390T
  1154. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1155. depends on PCI && SCSI
  1156. ---help---
  1157. This driver supports PCI SCSI host adapters based on the Am53C974A
  1158. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1159. PCscsi/PCnet (Am53/79C974) solutions.
  1160. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1161. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1162. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1163. To compile this driver as a module, choose M here: the
  1164. module will be called tmscsim.
  1165. config SCSI_T128
  1166. tristate "Trantor T128/T128F/T228 SCSI support"
  1167. depends on ISA && SCSI
  1168. ---help---
  1169. This is support for a SCSI host adapter. It is explained in section
  1170. 3.11 of the SCSI-HOWTO, available from
  1171. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1172. of the box, you may have to change some settings in
  1173. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1174. Adaptec, and some former Trantor products are being sold under the
  1175. Adaptec name.
  1176. To compile this driver as a module, choose M here: the
  1177. module will be called t128.
  1178. config SCSI_U14_34F
  1179. tristate "UltraStor 14F/34F support"
  1180. depends on ISA && SCSI && ISA_DMA_API
  1181. ---help---
  1182. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1183. The source at <file:drivers/scsi/u14-34f.c> contains some
  1184. information about this hardware. If the driver doesn't work out of
  1185. the box, you may have to change some settings in
  1186. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1187. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1188. another driver for the same hardware: "UltraStor SCSI support",
  1189. below. You should say Y to both only if you want 24F support as
  1190. well.
  1191. To compile this driver as a module, choose M here: the
  1192. module will be called u14-34f.
  1193. config SCSI_U14_34F_TAGGED_QUEUE
  1194. bool "enable tagged command queueing"
  1195. depends on SCSI_U14_34F
  1196. help
  1197. This is a feature of SCSI-2 which improves performance: the host
  1198. adapter can send several SCSI commands to a device's queue even if
  1199. previous commands haven't finished yet.
  1200. This is equivalent to the "u14-34f=tc:y" boot option.
  1201. config SCSI_U14_34F_LINKED_COMMANDS
  1202. bool "enable elevator sorting"
  1203. depends on SCSI_U14_34F
  1204. help
  1205. This option enables elevator sorting for all probed SCSI disks and
  1206. CD-ROMs. It definitely reduces the average seek distance when doing
  1207. random seeks, but this does not necessarily result in a noticeable
  1208. performance improvement: your mileage may vary...
  1209. This is equivalent to the "u14-34f=lc:y" boot option.
  1210. config SCSI_U14_34F_MAX_TAGS
  1211. int "maximum number of queued commands"
  1212. depends on SCSI_U14_34F
  1213. default "8"
  1214. help
  1215. This specifies how many SCSI commands can be maximally queued for
  1216. each probed SCSI device. You should reduce the default value of 8
  1217. only if you have disks with buggy or limited tagged command support.
  1218. Minimum is 2 and maximum is 14. This value is also the window size
  1219. used by the elevator sorting option above. The effective value used
  1220. by the driver for each probed SCSI device is reported at boot time.
  1221. This is equivalent to the "u14-34f=mq:8" boot option.
  1222. config SCSI_ULTRASTOR
  1223. tristate "UltraStor SCSI support"
  1224. depends on X86 && ISA && SCSI
  1225. ---help---
  1226. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1227. adapter family. This driver is explained in section 3.12 of the
  1228. SCSI-HOWTO, available from
  1229. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1230. of the box, you may have to change some settings in
  1231. <file:drivers/scsi/ultrastor.h>.
  1232. Note that there is also another driver for the same hardware:
  1233. "UltraStor 14F/34F support", above.
  1234. To compile this driver as a module, choose M here: the
  1235. module will be called ultrastor.
  1236. config SCSI_NSP32
  1237. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1238. depends on PCI && SCSI && !64BIT
  1239. help
  1240. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1241. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1242. <http://www.tldp.org/docs.html#howto>.
  1243. To compile this driver as a module, choose M here: the
  1244. module will be called nsp32.
  1245. config SCSI_DEBUG
  1246. tristate "SCSI debugging host simulator"
  1247. depends on SCSI
  1248. help
  1249. This is a host adapter simulator that can simulate multiple hosts
  1250. each with multiple dummy SCSI devices (disks). It defaults to one
  1251. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1252. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1253. dummy disks are simulated, they share the same kernel RAM for
  1254. their storage. See <http://www.torque.net/sg/sdebug.html> for more
  1255. information. This driver is primarily of use to those testing the
  1256. SCSI and block subsystems. If unsure, say N.
  1257. config SCSI_MESH
  1258. tristate "MESH (Power Mac internal SCSI) support"
  1259. depends on PPC32 && PPC_PMAC && SCSI
  1260. help
  1261. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1262. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1263. other Power Macintoshes do). Say Y to include support for this SCSI
  1264. adaptor.
  1265. To compile this driver as a module, choose M here: the
  1266. module will be called mesh.
  1267. config SCSI_MESH_SYNC_RATE
  1268. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1269. depends on SCSI_MESH
  1270. default "5"
  1271. help
  1272. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1273. drives a bus which is entirely internal to the machine (such as the
  1274. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1275. operation at up to 10 MB/s. On machines where the SCSI bus
  1276. controlled by the MESH can have external devices connected, it is
  1277. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1278. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1279. to disable synchronous operation.
  1280. config SCSI_MESH_RESET_DELAY_MS
  1281. int "initial bus reset delay (ms) (0 = no reset)"
  1282. depends on SCSI_MESH
  1283. default "4000"
  1284. config SCSI_MAC53C94
  1285. tristate "53C94 (Power Mac external SCSI) support"
  1286. depends on PPC32 && PPC_PMAC && SCSI
  1287. help
  1288. On Power Macintoshes (and clones) with two SCSI buses, the external
  1289. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1290. machines which only have one SCSI bus, such as the 7200, also use
  1291. the 53C94. Say Y to include support for the 53C94.
  1292. To compile this driver as a module, choose M here: the
  1293. module will be called mac53c94.
  1294. source "drivers/scsi/arm/Kconfig"
  1295. config JAZZ_ESP
  1296. bool "MIPS JAZZ FAS216 SCSI support"
  1297. depends on MACH_JAZZ && SCSI
  1298. help
  1299. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1300. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1301. systems.
  1302. config A3000_SCSI
  1303. tristate "A3000 WD33C93A support"
  1304. depends on AMIGA && SCSI
  1305. help
  1306. If you have an Amiga 3000 and have SCSI devices connected to the
  1307. built-in SCSI controller, say Y. Otherwise, say N.
  1308. To compile this driver as a module, choose M here: the
  1309. module will be called wd33c93.
  1310. config A2091_SCSI
  1311. tristate "A2091/A590 WD33C93A support"
  1312. depends on ZORRO && SCSI
  1313. help
  1314. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1315. say N.
  1316. To compile this driver as a module, choose M here: the
  1317. module will be called wd33c93.
  1318. config GVP11_SCSI
  1319. tristate "GVP Series II WD33C93A support"
  1320. depends on ZORRO && SCSI
  1321. ---help---
  1322. If you have a Great Valley Products Series II SCSI controller,
  1323. answer Y. Also say Y if you have a later model of GVP SCSI
  1324. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1325. answer N. This driver does NOT work for the T-Rex series of
  1326. accelerators from TekMagic and GVP-M.
  1327. To compile this driver as a module, choose M here: the
  1328. module will be called gvp11.
  1329. config CYBERSTORM_SCSI
  1330. tristate "CyberStorm SCSI support"
  1331. depends on ZORRO && SCSI
  1332. help
  1333. If you have an Amiga with an original (MkI) Phase5 Cyberstorm
  1334. accelerator board and the optional Cyberstorm SCSI controller,
  1335. answer Y. Otherwise, say N.
  1336. config CYBERSTORMII_SCSI
  1337. tristate "CyberStorm Mk II SCSI support"
  1338. depends on ZORRO && SCSI
  1339. help
  1340. If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
  1341. and the optional Cyberstorm SCSI controller, say Y. Otherwise,
  1342. answer N.
  1343. config BLZ2060_SCSI
  1344. tristate "Blizzard 2060 SCSI support"
  1345. depends on ZORRO && SCSI
  1346. help
  1347. If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
  1348. and want to use the onboard SCSI controller, say Y. Otherwise,
  1349. answer N.
  1350. config BLZ1230_SCSI
  1351. tristate "Blizzard 1230IV/1260 SCSI support"
  1352. depends on ZORRO && SCSI
  1353. help
  1354. If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
  1355. 1260 accelerator, and the optional SCSI module, say Y. Otherwise,
  1356. say N.
  1357. config FASTLANE_SCSI
  1358. tristate "Fastlane SCSI support"
  1359. depends on ZORRO && SCSI
  1360. help
  1361. If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
  1362. one in the near future, say Y to this question. Otherwise, say N.
  1363. config SCSI_AMIGA7XX
  1364. bool "Amiga NCR53c710 SCSI support (EXPERIMENTAL)"
  1365. depends on AMIGA && SCSI && EXPERIMENTAL && BROKEN
  1366. help
  1367. Support for various NCR53c710-based SCSI controllers on the Amiga.
  1368. This includes:
  1369. - the builtin SCSI controller on the Amiga 4000T,
  1370. - the Amiga 4091 Zorro III SCSI-2 controller,
  1371. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1372. (info at
  1373. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1374. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1375. accelerator card for the Amiga 1200,
  1376. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1377. Note that all of the above SCSI controllers, except for the builtin
  1378. SCSI controller on the Amiga 4000T, reside on the Zorro expansion
  1379. bus, so you also have to enable Zorro bus support if you want to use
  1380. them.
  1381. config OKTAGON_SCSI
  1382. tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
  1383. depends on ZORRO && SCSI && EXPERIMENTAL
  1384. help
  1385. If you have the BSC Oktagon SCSI disk controller for the Amiga, say
  1386. Y to this question. If you're in doubt about whether you have one,
  1387. see the picture at
  1388. <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
  1389. config ATARI_SCSI
  1390. tristate "Atari native SCSI support"
  1391. depends on ATARI && SCSI && BROKEN
  1392. ---help---
  1393. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1394. Falcon, ...) say Y to get it supported. Of course also, if you have
  1395. a compatible SCSI controller (e.g. for Medusa).
  1396. To compile this driver as a module, choose M here: the
  1397. module will be called atari_scsi.
  1398. This driver supports both styles of NCR integration into the
  1399. system: the TT style (separate DMA), and the Falcon style (via
  1400. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1401. in the Hades (without DMA).
  1402. config ATARI_SCSI_TOSHIBA_DELAY
  1403. bool "Long delays for Toshiba CD-ROMs"
  1404. depends on ATARI_SCSI
  1405. help
  1406. This option increases the delay after a SCSI arbitration to
  1407. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1408. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1409. would impact performance a bit, so say N.
  1410. config ATARI_SCSI_RESET_BOOT
  1411. bool "Reset SCSI-devices at boottime"
  1412. depends on ATARI_SCSI
  1413. help
  1414. Reset the devices on your Atari whenever it boots. This makes the
  1415. boot process fractionally longer but may assist recovery from errors
  1416. that leave the devices with SCSI operations partway completed.
  1417. config TT_DMA_EMUL
  1418. bool "Hades SCSI DMA emulator"
  1419. depends on ATARI_SCSI && HADES
  1420. help
  1421. This option enables code which emulates the TT SCSI DMA chip on the
  1422. Hades. This increases the SCSI transfer rates at least ten times
  1423. compared to PIO transfers.
  1424. config MAC_SCSI
  1425. bool "Macintosh NCR5380 SCSI"
  1426. depends on MAC && SCSI
  1427. help
  1428. This is the NCR 5380 SCSI controller included on most of the 68030
  1429. based Macintoshes. If you have one of these say Y and read the
  1430. SCSI-HOWTO, available from
  1431. <http://www.tldp.org/docs.html#howto>.
  1432. config SCSI_MAC_ESP
  1433. tristate "Macintosh NCR53c9[46] SCSI"
  1434. depends on MAC && SCSI
  1435. help
  1436. This is the NCR 53c9x SCSI controller found on most of the 68040
  1437. based Macintoshes. If you have one of these say Y and read the
  1438. SCSI-HOWTO, available from
  1439. <http://www.tldp.org/docs.html#howto>.
  1440. To compile this driver as a module, choose M here: the
  1441. module will be called mac_esp.
  1442. config MVME147_SCSI
  1443. bool "WD33C93 SCSI driver for MVME147"
  1444. depends on MVME147 && SCSI
  1445. help
  1446. Support for the on-board SCSI controller on the Motorola MVME147
  1447. single-board computer.
  1448. config MVME16x_SCSI
  1449. bool "NCR53C710 SCSI driver for MVME16x"
  1450. depends on MVME16x && SCSI && BROKEN
  1451. help
  1452. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1453. SCSI controller chip. Almost everyone using one of these boards
  1454. will want to say Y to this question.
  1455. config BVME6000_SCSI
  1456. bool "NCR53C710 SCSI driver for BVME6000"
  1457. depends on BVME6000 && SCSI && BROKEN
  1458. help
  1459. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1460. SCSI controller chip. Almost everyone using one of these boards
  1461. will want to say Y to this question.
  1462. config SCSI_NCR53C7xx_FAST
  1463. bool "allow FAST-SCSI [10MHz]"
  1464. depends on SCSI_AMIGA7XX || MVME16x_SCSI || BVME6000_SCSI
  1465. help
  1466. This will enable 10MHz FAST-SCSI transfers with your host
  1467. adapter. Some systems have problems with that speed, so it's safest
  1468. to say N here.
  1469. config SUN3_SCSI
  1470. tristate "Sun3 NCR5380 SCSI"
  1471. depends on SUN3 && SCSI && BROKEN
  1472. help
  1473. This option will enable support for the OBIO (onboard io) NCR5380
  1474. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1475. "Sun3" type VME scsi controllers also based on the NCR5380.
  1476. General Linux information on the Sun 3 series (now discontinued)
  1477. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1478. config SUN3X_ESP
  1479. bool "Sun3x ESP SCSI"
  1480. depends on SUN3X && SCSI
  1481. help
  1482. The ESP was an on-board SCSI controller used on Sun 3/80
  1483. machines. Say Y here to compile in support for it.
  1484. config SCSI_SUNESP
  1485. tristate "Sparc ESP Scsi Driver"
  1486. depends on SBUS && SCSI
  1487. help
  1488. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1489. chipset is present in most SPARC SBUS-based computers.
  1490. To compile this driver as a module, choose M here: the
  1491. module will be called esp.
  1492. # bool 'Cyberstorm Mk III SCSI support (EXPERIMENTAL)' CONFIG_CYBERSTORMIII_SCSI
  1493. config ZFCP
  1494. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1495. depends on ARCH_S390 && QDIO && SCSI
  1496. select SCSI_FC_ATTRS
  1497. help
  1498. If you want to access SCSI devices attached to your IBM eServer
  1499. zSeries by means of Fibre Channel interfaces say Y.
  1500. For details please refer to the documentation provided by IBM at
  1501. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1502. This driver is also available as a module. This module will be
  1503. called zfcp. If you want to compile it as a module, say M here
  1504. and read <file:Documentation/modules.txt>.
  1505. endmenu
  1506. source "drivers/scsi/pcmcia/Kconfig"
  1507. endmenu