12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796
  1. menu "SCSI device support"
  2. config RAID_ATTRS
  3. tristate "RAID Transport Class"
  4. default n
  5. depends on BLOCK
  6. ---help---
  7. Provides RAID
  8. config SCSI
  9. tristate "SCSI device support"
  10. depends on BLOCK
  11. ---help---
  12. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  13. any other SCSI device under Linux, say Y and make sure that you know
  14. the name of your SCSI host adapter (the card inside your computer
  15. that "speaks" the SCSI protocol, also called SCSI controller),
  16. because you will be asked for it.
  17. You also need to say Y here if you have a device which speaks
  18. the SCSI protocol. Examples of this include the parallel port
  19. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  20. Channel, FireWire storage and the IDE-SCSI emulation driver.
  21. To compile this driver as a module, choose M here and read
  22. <file:Documentation/scsi/scsi.txt>.
  23. The module will be called scsi_mod.
  24. However, do not compile this as a module if your root file system
  25. (the one containing the directory /) is located on a SCSI device.
  26. config SCSI_TGT
  27. tristate "SCSI target support"
  28. depends on SCSI && EXPERIMENTAL
  29. ---help---
  30. If you want to use SCSI target mode drivers enable this option.
  31. If you choose M, the module will be called scsi_tgt.
  32. config SCSI_NETLINK
  33. bool
  34. default n
  35. select NET
  36. config SCSI_PROC_FS
  37. bool "legacy /proc/scsi/ support"
  38. depends on SCSI && PROC_FS
  39. default y
  40. ---help---
  41. This option enables support for the various files in
  42. /proc/scsi. In Linux 2.6 this has been superseded by
  43. files in sysfs but many legacy applications rely on this.
  44. If unsure say Y.
  45. comment "SCSI support type (disk, tape, CD-ROM)"
  46. depends on SCSI
  47. config BLK_DEV_SD
  48. tristate "SCSI disk support"
  49. depends on SCSI
  50. ---help---
  51. If you want to use SCSI hard disks, Fibre Channel disks,
  52. USB storage or the SCSI or parallel port version of
  53. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  54. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  55. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  56. CD-ROMs.
  57. To compile this driver as a module, choose M here and read
  58. <file:Documentation/scsi/scsi.txt>.
  59. The module will be called sd_mod.
  60. Do not compile this driver as a module if your root file system
  61. (the one containing the directory /) is located on a SCSI disk.
  62. In this case, do not compile the driver for your SCSI host adapter
  63. (below) as a module either.
  64. config CHR_DEV_ST
  65. tristate "SCSI tape support"
  66. depends on SCSI
  67. ---help---
  68. If you want to use a SCSI tape drive under Linux, say Y and read the
  69. SCSI-HOWTO, available from
  70. <http://www.tldp.org/docs.html#howto>, and
  71. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  72. for SCSI CD-ROMs.
  73. To compile this driver as a module, choose M here and read
  74. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  75. config CHR_DEV_OSST
  76. tristate "SCSI OnStream SC-x0 tape support"
  77. depends on SCSI
  78. ---help---
  79. The OnStream SC-x0 SCSI tape drives cannot be driven by the
  80. standard st driver, but instead need this special osst driver and
  81. use the /dev/osstX char device nodes (major 206). Via usb-storage
  82. and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
  83. as well. Note that there is also a second generation of OnStream
  84. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  85. tapes (QIC-157) and can be driven by the standard driver st.
  86. For more information, you may have a look at the SCSI-HOWTO
  87. <http://www.tldp.org/docs.html#howto> and
  88. <file:Documentation/scsi/osst.txt> in the kernel source.
  89. More info on the OnStream driver may be found on
  90. <http://linux1.onstream.nl/test/>
  91. Please also have a look at the standard st docu, as most of it
  92. applies to osst as well.
  93. To compile this driver as a module, choose M here and read
  94. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  95. config BLK_DEV_SR
  96. tristate "SCSI CDROM support"
  97. depends on SCSI
  98. ---help---
  99. If you want to use a SCSI or FireWire CD-ROM under Linux,
  100. say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
  101. <http://www.tldp.org/docs.html#howto>. Also make sure to say
  102. Y or M to "ISO 9660 CD-ROM file system support" later.
  103. To compile this driver as a module, choose M here and read
  104. <file:Documentation/scsi/scsi.txt>.
  105. The module will be called sr_mod.
  106. config BLK_DEV_SR_VENDOR
  107. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  108. depends on BLK_DEV_SR
  109. help
  110. This enables the usage of vendor specific SCSI commands. This is
  111. required to support multisession CDs with old NEC/TOSHIBA cdrom
  112. drives (and HP Writers). If you have such a drive and get the first
  113. session only, try saying Y here; everybody else says N.
  114. config CHR_DEV_SG
  115. tristate "SCSI generic support"
  116. depends on SCSI
  117. ---help---
  118. If you want to use SCSI scanners, synthesizers or CD-writers or just
  119. about anything having "SCSI" in its name other than hard disks,
  120. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  121. directly, so you need some additional software which knows how to
  122. talk to these devices using the SCSI protocol:
  123. For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
  124. writer software look at Cdrtools
  125. (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
  126. and for burning a "disk at once": CDRDAO
  127. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  128. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  129. For other devices, it's possible that you'll have to write the
  130. driver software yourself. Please read the file
  131. <file:Documentation/scsi/scsi-generic.txt> for more information.
  132. To compile this driver as a module, choose M here and read
  133. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  134. If unsure, say N.
  135. config CHR_DEV_SCH
  136. tristate "SCSI media changer support"
  137. depends on SCSI
  138. ---help---
  139. This is a driver for SCSI media changers. Most common devices are
  140. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  141. don't need this for those tiny 6-slot cdrom changers. Media
  142. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  143. If you have such hardware and want to use it with linux, say Y
  144. here. Check <file:Documentation/scsi-changer.txt> for details.
  145. If you want to compile this as a module ( = code which can be
  146. inserted in and removed from the running kernel whenever you want),
  147. say M here and read <file:Documentation/modules.txt> and
  148. <file:Documentation/scsi.txt>. The module will be called ch.o.
  149. If unsure, say N.
  150. comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
  151. depends on SCSI
  152. config SCSI_MULTI_LUN
  153. bool "Probe all LUNs on each SCSI device"
  154. depends on SCSI
  155. help
  156. If you have a SCSI device that supports more than one LUN (Logical
  157. Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
  158. can say Y here to force the SCSI driver to probe for multiple LUNs.
  159. A SCSI device with multiple LUNs acts logically like multiple SCSI
  160. devices. The vast majority of SCSI devices have only one LUN, and
  161. so most people can say N here. The max_luns boot/module parameter
  162. allows to override this setting.
  163. config SCSI_CONSTANTS
  164. bool "Verbose SCSI error reporting (kernel size +=12K)"
  165. depends on SCSI
  166. help
  167. The error messages regarding your SCSI hardware will be easier to
  168. understand if you say Y here; it will enlarge your kernel by about
  169. 12 KB. If in doubt, say Y.
  170. config SCSI_LOGGING
  171. bool "SCSI logging facility"
  172. depends on SCSI
  173. ---help---
  174. This turns on a logging facility that can be used to debug a number
  175. of SCSI related problems.
  176. If you say Y here, no logging output will appear by default, but you
  177. can enable logging by saying Y to "/proc file system support" and
  178. "Sysctl support" below and executing the command
  179. echo "scsi log token [level]" > /proc/scsi/scsi
  180. at boot time after the /proc file system has been mounted.
  181. There are a number of things that can be used for 'token' (you can
  182. find them in the source: <file:drivers/scsi/scsi.c>), and this
  183. allows you to select the types of information you want, and the
  184. level allows you to select the level of verbosity.
  185. If you say N here, it may be harder to track down some types of SCSI
  186. problems. If you say Y here your kernel will be somewhat larger, but
  187. there should be no noticeable performance impact as long as you have
  188. logging turned off.
  189. config SCSI_SCAN_ASYNC
  190. bool "Asynchronous SCSI scanning"
  191. depends on SCSI
  192. help
  193. The SCSI subsystem can probe for devices while the rest of the
  194. system continues booting, and even probe devices on different
  195. busses in parallel, leading to a significant speed-up.
  196. If you have built SCSI as modules, enabling this option can
  197. be a problem as the devices may not have been found by the
  198. time your system expects them to have been. You can load the
  199. scsi_wait_scan module to ensure that all scans have completed.
  200. If you build your SCSI drivers into the kernel, then everything
  201. will work fine if you say Y here.
  202. You can override this choice by specifying scsi_mod.scan="sync"
  203. or "async" on the kernel's command line.
  204. menu "SCSI Transports"
  205. depends on SCSI
  206. config SCSI_SPI_ATTRS
  207. tristate "Parallel SCSI (SPI) Transport Attributes"
  208. depends on SCSI
  209. help
  210. If you wish to export transport-specific information about
  211. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  212. config SCSI_FC_ATTRS
  213. tristate "FiberChannel Transport Attributes"
  214. depends on SCSI
  215. select SCSI_NETLINK
  216. help
  217. If you wish to export transport-specific information about
  218. each attached FiberChannel device to sysfs, say Y.
  219. Otherwise, say N.
  220. config SCSI_ISCSI_ATTRS
  221. tristate "iSCSI Transport Attributes"
  222. depends on SCSI && NET
  223. help
  224. If you wish to export transport-specific information about
  225. each attached iSCSI device to sysfs, say Y.
  226. Otherwise, say N.
  227. config SCSI_SAS_ATTRS
  228. tristate "SAS Transport Attributes"
  229. depends on SCSI
  230. help
  231. If you wish to export transport-specific information about
  232. each attached SAS device to sysfs, say Y.
  233. source "drivers/scsi/libsas/Kconfig"
  234. endmenu
  235. menu "SCSI low-level drivers"
  236. depends on SCSI!=n
  237. config ISCSI_TCP
  238. tristate "iSCSI Initiator over TCP/IP"
  239. depends on SCSI && INET
  240. select CRYPTO
  241. select CRYPTO_MD5
  242. select CRYPTO_CRC32C
  243. select SCSI_ISCSI_ATTRS
  244. help
  245. The iSCSI Driver provides a host with the ability to access storage
  246. through an IP network. The driver uses the iSCSI protocol to transport
  247. SCSI requests and responses over a TCP/IP network between the host
  248. (the "initiator") and "targets". Architecturally, the iSCSI driver
  249. combines with the host's TCP/IP stack, network drivers, and Network
  250. Interface Card (NIC) to provide the same functions as a SCSI or a
  251. Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
  252. To compile this driver as a module, choose M here: the
  253. module will be called iscsi_tcp.
  254. The userspace component needed to initialize the driver, documentation,
  255. and sample configuration files can be found here:
  256. http://linux-iscsi.sf.net
  257. config SGIWD93_SCSI
  258. tristate "SGI WD93C93 SCSI Driver"
  259. depends on SGI_IP22 && SCSI
  260. help
  261. If you have a Western Digital WD93 SCSI controller on
  262. an SGI MIPS system, say Y. Otherwise, say N.
  263. config SCSI_DECNCR
  264. tristate "DEC NCR53C94 Scsi Driver"
  265. depends on MACH_DECSTATION && SCSI && TC
  266. help
  267. Say Y here to support the NCR53C94 SCSI controller chips on IOASIC
  268. based TURBOchannel DECstations and TURBOchannel PMAZ-A cards.
  269. config SCSI_DECSII
  270. tristate "DEC SII Scsi Driver"
  271. depends on MACH_DECSTATION && SCSI && 32BIT
  272. config BLK_DEV_3W_XXXX_RAID
  273. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  274. depends on PCI && SCSI
  275. help
  276. 3ware is the only hardware ATA-Raid product in Linux to date.
  277. This card is 2,4, or 8 channel master mode support only.
  278. SCSI support required!!!
  279. <http://www.3ware.com/>
  280. Please read the comments at the top of
  281. <file:drivers/scsi/3w-xxxx.c>.
  282. config SCSI_3W_9XXX
  283. tristate "3ware 9xxx SATA-RAID support"
  284. depends on PCI && SCSI
  285. help
  286. This driver supports the 9000 series 3ware SATA-RAID cards.
  287. <http://www.amcc.com>
  288. Please read the comments at the top of
  289. <file:drivers/scsi/3w-9xxx.c>.
  290. config SCSI_7000FASST
  291. tristate "7000FASST SCSI support"
  292. depends on ISA && SCSI && ISA_DMA_API
  293. help
  294. This driver supports the Western Digital 7000 SCSI host adapter
  295. family. Some information is in the source:
  296. <file:drivers/scsi/wd7000.c>.
  297. To compile this driver as a module, choose M here: the
  298. module will be called wd7000.
  299. config SCSI_ACARD
  300. tristate "ACARD SCSI support"
  301. depends on PCI && SCSI
  302. help
  303. This driver supports the ACARD SCSI host adapter.
  304. Support Chip <ATP870 ATP876 ATP880 ATP885>
  305. To compile this driver as a module, choose M here: the
  306. module will be called atp870u.
  307. config SCSI_AHA152X
  308. tristate "Adaptec AHA152X/2825 support"
  309. depends on ISA && SCSI && !64BIT
  310. select SCSI_SPI_ATTRS
  311. ---help---
  312. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  313. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  314. must be manually specified in this case.
  315. It is explained in section 3.3 of the SCSI-HOWTO, available from
  316. <http://www.tldp.org/docs.html#howto>. You might also want to
  317. read the file <file:Documentation/scsi/aha152x.txt>.
  318. To compile this driver as a module, choose M here: the
  319. module will be called aha152x.
  320. config SCSI_AHA1542
  321. tristate "Adaptec AHA1542 support"
  322. depends on ISA && SCSI && ISA_DMA_API
  323. ---help---
  324. This is support for a SCSI host adapter. It is explained in section
  325. 3.4 of the SCSI-HOWTO, available from
  326. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  327. purchased by Adaptec, and some former Trantor products are being
  328. sold under the Adaptec name. If it doesn't work out of the box, you
  329. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  330. To compile this driver as a module, choose M here: the
  331. module will be called aha1542.
  332. config SCSI_AHA1740
  333. tristate "Adaptec AHA1740 support"
  334. depends on EISA && SCSI
  335. ---help---
  336. This is support for a SCSI host adapter. It is explained in section
  337. 3.5 of the SCSI-HOWTO, available from
  338. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  339. of the box, you may have to change some settings in
  340. <file:drivers/scsi/aha1740.h>.
  341. To compile this driver as a module, choose M here: the
  342. module will be called aha1740.
  343. config SCSI_AACRAID
  344. tristate "Adaptec AACRAID support"
  345. depends on SCSI && PCI
  346. help
  347. This driver supports a variety of Dell, HP, Adaptec, IBM and
  348. ICP storage products. For a list of supported products, refer
  349. to <file:Documentation/scsi/aacraid.txt>.
  350. To compile this driver as a module, choose M here: the module
  351. will be called aacraid.
  352. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  353. config SCSI_AIC7XXX_OLD
  354. tristate "Adaptec AIC7xxx support (old driver)"
  355. depends on (ISA || EISA || PCI ) && SCSI
  356. help
  357. WARNING This driver is an older aic7xxx driver and is no longer
  358. under active development. Adaptec, Inc. is writing a new driver to
  359. take the place of this one, and it is recommended that whenever
  360. possible, people should use the new Adaptec written driver instead
  361. of this one. This driver will eventually be phased out entirely.
  362. This is support for the various aic7xxx based Adaptec SCSI
  363. controllers. These include the 274x EISA cards; 284x VLB cards;
  364. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  365. motherboard based SCSI controllers from Adaptec. It does not support
  366. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  367. support them. It does not support the 2920 cards from Adaptec that
  368. use the Future Domain SCSI controller chip. For those cards, you
  369. need the "Future Domain 16xx SCSI support" driver.
  370. In general, if the controller is based on an Adaptec SCSI controller
  371. chip from the aic777x series or the aic78xx series, this driver
  372. should work. The only exception is the 7810 which is specifically
  373. not supported (that's the RAID controller chip on the AAA-13x
  374. cards).
  375. Note that the AHA2920 SCSI host adapter is *not* supported by this
  376. driver; choose "Future Domain 16xx SCSI support" instead if you have
  377. one of those.
  378. Information on the configuration options for this controller can be
  379. found by checking the help file for each of the available
  380. configuration options. You should read
  381. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  382. contacting the maintainer with any questions. The SCSI-HOWTO,
  383. available from <http://www.tldp.org/docs.html#howto>, can also
  384. be of great help.
  385. To compile this driver as a module, choose M here: the
  386. module will be called aic7xxx_old.
  387. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  388. source "drivers/scsi/aic94xx/Kconfig"
  389. # All the I2O code and drivers do not seem to be 64bit safe.
  390. config SCSI_DPT_I2O
  391. tristate "Adaptec I2O RAID support "
  392. depends on !64BIT && SCSI && PCI
  393. help
  394. This driver supports all of Adaptec's I2O based RAID controllers as
  395. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  396. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  397. To compile this driver as a module, choose M here: the
  398. module will be called dpt_i2o.
  399. config SCSI_ADVANSYS
  400. tristate "AdvanSys SCSI support"
  401. depends on SCSI
  402. depends on ISA || EISA || PCI
  403. depends on BROKEN || X86_32
  404. help
  405. This is a driver for all SCSI host adapters manufactured by
  406. AdvanSys. It is documented in the kernel source in
  407. <file:drivers/scsi/advansys.c>.
  408. To compile this driver as a module, choose M here: the
  409. module will be called advansys.
  410. config SCSI_IN2000
  411. tristate "Always IN2000 SCSI support"
  412. depends on ISA && SCSI
  413. help
  414. This is support for an ISA bus SCSI host adapter. You'll find more
  415. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  416. out of the box, you may have to change the jumpers for IRQ or
  417. address selection.
  418. To compile this driver as a module, choose M here: the
  419. module will be called in2000.
  420. config SCSI_ARCMSR
  421. tristate "ARECA ARC11X0[PCI-X]/ARC12X0[PCI-EXPRESS] SATA-RAID support"
  422. depends on PCI && SCSI
  423. help
  424. This driver supports all of ARECA's SATA RAID controller cards.
  425. This is an ARECA-maintained driver by Erich Chen.
  426. If you have any problems, please mail to: < erich@areca.com.tw >
  427. Areca supports Linux RAID config tools.
  428. < http://www.areca.com.tw >
  429. To compile this driver as a module, choose M here: the
  430. module will be called arcmsr (modprobe arcmsr).
  431. source "drivers/scsi/megaraid/Kconfig.megaraid"
  432. config SCSI_HPTIOP
  433. tristate "HighPoint RocketRAID 3xxx Controller support"
  434. depends on SCSI && PCI
  435. help
  436. This option enables support for HighPoint RocketRAID 3xxx
  437. controllers.
  438. To compile this driver as a module, choose M here; the module
  439. will be called hptiop. If unsure, say N.
  440. config SCSI_BUSLOGIC
  441. tristate "BusLogic SCSI support"
  442. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API
  443. ---help---
  444. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  445. Adapters. Consult the SCSI-HOWTO, available from
  446. <http://www.tldp.org/docs.html#howto>, and the files
  447. <file:Documentation/scsi/BusLogic.txt> and
  448. <file:Documentation/scsi/FlashPoint.txt> for more information.
  449. To compile this driver as a module, choose M here: the
  450. module will be called BusLogic.
  451. config SCSI_OMIT_FLASHPOINT
  452. bool "Omit FlashPoint support"
  453. depends on SCSI_BUSLOGIC
  454. help
  455. This option allows you to omit the FlashPoint support from the
  456. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  457. substantial, so users of MultiMaster Host Adapters may wish to omit
  458. it.
  459. config SCSI_DMX3191D
  460. tristate "DMX3191D SCSI support"
  461. depends on PCI && SCSI
  462. select SCSI_SPI_ATTRS
  463. help
  464. This is support for Domex DMX3191D SCSI Host Adapters.
  465. To compile this driver as a module, choose M here: the
  466. module will be called dmx3191d.
  467. config SCSI_DTC3280
  468. tristate "DTC3180/3280 SCSI support"
  469. depends on ISA && SCSI
  470. select SCSI_SPI_ATTRS
  471. help
  472. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  473. the SCSI-HOWTO, available from
  474. <http://www.tldp.org/docs.html#howto>, and the file
  475. <file:Documentation/scsi/dtc3x80.txt>.
  476. To compile this driver as a module, choose M here: the
  477. module will be called dtc.
  478. config SCSI_EATA
  479. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  480. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  481. ---help---
  482. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  483. ISA and all EISA I/O addresses are probed looking for the "EATA"
  484. signature. The addresses of all the PCI SCSI controllers reported
  485. by the PCI subsystem are probed as well.
  486. You want to read the start of <file:drivers/scsi/eata.c> and the
  487. SCSI-HOWTO, available from
  488. <http://www.tldp.org/docs.html#howto>.
  489. To compile this driver as a module, choose M here: the
  490. module will be called eata.
  491. config SCSI_EATA_TAGGED_QUEUE
  492. bool "enable tagged command queueing"
  493. depends on SCSI_EATA
  494. help
  495. This is a feature of SCSI-2 which improves performance: the host
  496. adapter can send several SCSI commands to a device's queue even if
  497. previous commands haven't finished yet.
  498. This is equivalent to the "eata=tc:y" boot option.
  499. config SCSI_EATA_LINKED_COMMANDS
  500. bool "enable elevator sorting"
  501. depends on SCSI_EATA
  502. help
  503. This option enables elevator sorting for all probed SCSI disks and
  504. CD-ROMs. It definitely reduces the average seek distance when doing
  505. random seeks, but this does not necessarily result in a noticeable
  506. performance improvement: your mileage may vary...
  507. This is equivalent to the "eata=lc:y" boot option.
  508. config SCSI_EATA_MAX_TAGS
  509. int "maximum number of queued commands"
  510. depends on SCSI_EATA
  511. default "16"
  512. help
  513. This specifies how many SCSI commands can be maximally queued for
  514. each probed SCSI device. You should reduce the default value of 16
  515. only if you have disks with buggy or limited tagged command support.
  516. Minimum is 2 and maximum is 62. This value is also the window size
  517. used by the elevator sorting option above. The effective value used
  518. by the driver for each probed SCSI device is reported at boot time.
  519. This is equivalent to the "eata=mq:8" boot option.
  520. config SCSI_EATA_PIO
  521. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  522. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  523. ---help---
  524. This driver supports all EATA-PIO protocol compliant SCSI Host
  525. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  526. host adapters could also use this driver but are discouraged from
  527. doing so, since this driver only supports hard disks and lacks
  528. numerous features. You might want to have a look at the SCSI-HOWTO,
  529. available from <http://www.tldp.org/docs.html#howto>.
  530. To compile this driver as a module, choose M here: the
  531. module will be called eata_pio.
  532. config SCSI_FUTURE_DOMAIN
  533. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  534. depends on (ISA || PCI) && SCSI
  535. ---help---
  536. This is support for Future Domain's 16-bit SCSI host adapters
  537. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  538. other adapters based on the Future Domain chipsets (Quantum
  539. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  540. It is explained in section 3.7 of the SCSI-HOWTO, available from
  541. <http://www.tldp.org/docs.html#howto>.
  542. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  543. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  544. controller support"). This Future Domain driver works with the older
  545. Adaptec AHA-2920A boards with a Future Domain chip on them.
  546. To compile this driver as a module, choose M here: the
  547. module will be called fdomain.
  548. config SCSI_FD_MCS
  549. tristate "Future Domain MCS-600/700 SCSI support"
  550. depends on MCA_LEGACY && SCSI
  551. ---help---
  552. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  553. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  554. is identical to the MCS 700 and hence also supported by this driver.
  555. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  556. It supports multiple adapters in the same system.
  557. To compile this driver as a module, choose M here: the
  558. module will be called fd_mcs.
  559. config SCSI_GDTH
  560. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  561. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  562. ---help---
  563. Formerly called GDT SCSI Disk Array Controller Support.
  564. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  565. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  566. in the kernel source in <file:drivers/scsi/gdth.c> and
  567. <file:drivers/scsi/gdth.h.>
  568. To compile this driver as a module, choose M here: the
  569. module will be called gdth.
  570. config SCSI_GENERIC_NCR5380
  571. tristate "Generic NCR5380/53c400 SCSI PIO support"
  572. depends on ISA && SCSI
  573. select SCSI_SPI_ATTRS
  574. ---help---
  575. This is a driver for the old NCR 53c80 series of SCSI controllers
  576. on boards using PIO. Most boards such as the Trantor T130 fit this
  577. category, along with a large number of ISA 8bit controllers shipped
  578. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  579. you should select the specific driver for that card rather than
  580. generic 5380 support.
  581. It is explained in section 3.8 of the SCSI-HOWTO, available from
  582. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  583. of the box, you may have to change some settings in
  584. <file:drivers/scsi/g_NCR5380.h>.
  585. To compile this driver as a module, choose M here: the
  586. module will be called g_NCR5380.
  587. config SCSI_GENERIC_NCR5380_MMIO
  588. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  589. depends on ISA && SCSI
  590. select SCSI_SPI_ATTRS
  591. ---help---
  592. This is a driver for the old NCR 53c80 series of SCSI controllers
  593. on boards using memory mapped I/O.
  594. It is explained in section 3.8 of the SCSI-HOWTO, available from
  595. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  596. of the box, you may have to change some settings in
  597. <file:drivers/scsi/g_NCR5380.h>.
  598. To compile this driver as a module, choose M here: the
  599. module will be called g_NCR5380_mmio.
  600. config SCSI_GENERIC_NCR53C400
  601. bool "Enable NCR53c400 extensions"
  602. depends on SCSI_GENERIC_NCR5380
  603. help
  604. This enables certain optimizations for the NCR53c400 SCSI cards.
  605. You might as well try it out. Note that this driver will only probe
  606. for the Trantor T130B in its default configuration; you might have
  607. to pass a command line option to the kernel at boot time if it does
  608. not detect your card. See the file
  609. <file:Documentation/scsi/g_NCR5380.txt> for details.
  610. config SCSI_IBMMCA
  611. tristate "IBMMCA SCSI support"
  612. depends on MCA_LEGACY && SCSI
  613. ---help---
  614. This is support for the IBM SCSI adapter found in many of the PS/2
  615. series computers. These machines have an MCA bus, so you need to
  616. answer Y to "MCA support" as well and read
  617. <file:Documentation/mca.txt>.
  618. If the adapter isn't found during boot (a common problem for models
  619. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  620. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  621. if that doesn't work check your reference diskette). Owners of
  622. model 95 with a LED-matrix-display can in addition activate some
  623. activity info like under OS/2, but more informative, by setting
  624. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  625. bootparam" or see the documentation of your boot loader about how to
  626. pass options to the kernel.
  627. To compile this driver as a module, choose M here: the
  628. module will be called ibmmca.
  629. config IBMMCA_SCSI_ORDER_STANDARD
  630. bool "Standard SCSI-order"
  631. depends on SCSI_IBMMCA
  632. ---help---
  633. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  634. are assigned to the drive letters, starting with the lowest SCSI-id
  635. (physical number -- pun) to be drive C:, as seen from DOS and
  636. similar operating systems. When looking into papers describing the
  637. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  638. The SCSI-standard follows a hardware-hierarchy which says that id 7
  639. has the highest priority and id 0 the lowest. Therefore, the host
  640. adapters are still today everywhere placed as SCSI-id 7 by default.
  641. In the SCSI-standard, the drive letters express the priority of the
  642. disk. C: should be the hard disk, or a partition on it, with the
  643. highest priority. This must therefore be the disk with the highest
  644. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  645. original definition of the SCSI-standard as also industrial- and
  646. process-control-machines, like VME-CPUs running under realtime-OSes
  647. (e.g. LynxOS, OS9) do.
  648. If you like to run Linux on your MCA-machine with the same
  649. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  650. machine, which is in addition conformant to the SCSI-standard, you
  651. must say Y here. This is also necessary for MCA-Linux users who want
  652. to keep downward compatibility to older releases of the
  653. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  654. June 1997).
  655. If you like to have the lowest SCSI-id assigned as drive C:, as
  656. modern SCSI-BIOSes do, which does not conform to the standard, but
  657. is widespread and common in the PC-world of today, you must say N
  658. here. If unsure, say Y.
  659. config IBMMCA_SCSI_DEV_RESET
  660. bool "Reset SCSI-devices at boottime"
  661. depends on SCSI_IBMMCA
  662. ---help---
  663. By default, SCSI-devices are reset when the machine is powered on.
  664. However, some devices exist, like special-control-devices,
  665. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  666. not reset when switched on. If you say Y here, each device connected
  667. to your SCSI-bus will be issued a reset-command after it has been
  668. probed, while the kernel is booting. This may cause problems with
  669. more modern devices, like hard disks, which do not appreciate these
  670. reset commands, and can cause your system to hang. So say Y only if
  671. you know that one of your older devices needs it; N is the safe
  672. answer.
  673. config SCSI_IPS
  674. tristate "IBM ServeRAID support"
  675. depends on PCI && SCSI
  676. ---help---
  677. This is support for the IBM ServeRAID hardware RAID controllers.
  678. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  679. for more information. If this driver does not work correctly
  680. without modification please contact the author by email at
  681. <ipslinux@adaptec.com>.
  682. To compile this driver as a module, choose M here: the
  683. module will be called ips.
  684. config SCSI_IBMVSCSI
  685. tristate "IBM Virtual SCSI support"
  686. depends on PPC_PSERIES || PPC_ISERIES
  687. help
  688. This is the IBM POWER Virtual SCSI Client
  689. To compile this driver as a module, choose M here: the
  690. module will be called ibmvscsic.
  691. config SCSI_IBMVSCSIS
  692. tristate "IBM Virtual SCSI Server support"
  693. depends on PPC_PSERIES && SCSI_TGT && SCSI_SRP
  694. help
  695. This is the SRP target driver for IBM pSeries virtual environments.
  696. The userspace component needed to initialize the driver and
  697. documentation can be found:
  698. http://stgt.berlios.de/
  699. To compile this driver as a module, choose M here: the
  700. module will be called ibmvstgt.
  701. config SCSI_INITIO
  702. tristate "Initio 9100U(W) support"
  703. depends on PCI && SCSI
  704. help
  705. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  706. read the SCSI-HOWTO, available from
  707. <http://www.tldp.org/docs.html#howto>.
  708. To compile this driver as a module, choose M here: the
  709. module will be called initio.
  710. config SCSI_INIA100
  711. tristate "Initio INI-A100U2W support"
  712. depends on PCI && SCSI
  713. help
  714. This is support for the Initio INI-A100U2W SCSI host adapter.
  715. Please read the SCSI-HOWTO, available from
  716. <http://www.tldp.org/docs.html#howto>.
  717. To compile this driver as a module, choose M here: the
  718. module will be called a100u2w.
  719. config SCSI_PPA
  720. tristate "IOMEGA parallel port (ppa - older drives)"
  721. depends on SCSI && PARPORT_PC
  722. ---help---
  723. This driver supports older versions of IOMEGA's parallel port ZIP
  724. drive (a 100 MB removable media device).
  725. Note that you can say N here if you have the SCSI version of the ZIP
  726. drive: it will be supported automatically if you said Y to the
  727. generic "SCSI disk support", above.
  728. If you have the ZIP Plus drive or a more recent parallel port ZIP
  729. drive (if the supplied cable with the drive is labeled "AutoDetect")
  730. then you should say N here and Y to "IOMEGA parallel port (imm -
  731. newer drives)", below.
  732. For more information about this driver and how to use it you should
  733. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  734. the SCSI-HOWTO, which is available from
  735. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  736. you will still be able to use the parallel port for other tasks,
  737. such as a printer; it is safe to compile both drivers into the
  738. kernel.
  739. To compile this driver as a module, choose M here: the
  740. module will be called ppa.
  741. config SCSI_IMM
  742. tristate "IOMEGA parallel port (imm - newer drives)"
  743. depends on SCSI && PARPORT_PC
  744. ---help---
  745. This driver supports newer versions of IOMEGA's parallel port ZIP
  746. drive (a 100 MB removable media device).
  747. Note that you can say N here if you have the SCSI version of the ZIP
  748. drive: it will be supported automatically if you said Y to the
  749. generic "SCSI disk support", above.
  750. If you have the ZIP Plus drive or a more recent parallel port ZIP
  751. drive (if the supplied cable with the drive is labeled "AutoDetect")
  752. then you should say Y here; if you have an older ZIP drive, say N
  753. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  754. For more information about this driver and how to use it you should
  755. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  756. the SCSI-HOWTO, which is available from
  757. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  758. you will still be able to use the parallel port for other tasks,
  759. such as a printer; it is safe to compile both drivers into the
  760. kernel.
  761. To compile this driver as a module, choose M here: the
  762. module will be called imm.
  763. config SCSI_IZIP_EPP16
  764. bool "ppa/imm option - Use slow (but safe) EPP-16"
  765. depends on SCSI_PPA || SCSI_IMM
  766. ---help---
  767. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  768. allows them to act as expansion buses that can handle up to 64
  769. peripheral devices.
  770. Some parallel port chipsets are slower than their motherboard, and
  771. so we have to control the state of the chipset's FIFO queue every
  772. now and then to avoid data loss. This will be done if you say Y
  773. here.
  774. Generally, saying Y is the safe option and slows things down a bit.
  775. config SCSI_IZIP_SLOW_CTR
  776. bool "ppa/imm option - Assume slow parport control register"
  777. depends on SCSI_PPA || SCSI_IMM
  778. help
  779. Some parallel ports are known to have excessive delays between
  780. changing the parallel port control register and good data being
  781. available on the parallel port data/status register. This option
  782. forces a small delay (1.0 usec to be exact) after changing the
  783. control register to let things settle out. Enabling this option may
  784. result in a big drop in performance but some very old parallel ports
  785. (found in 386 vintage machines) will not work properly.
  786. Generally, saying N is fine.
  787. config SCSI_NCR53C406A
  788. tristate "NCR53c406a SCSI support"
  789. depends on ISA && SCSI
  790. help
  791. This is support for the NCR53c406a SCSI host adapter. For user
  792. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  793. in the kernel source. Also read the SCSI-HOWTO, available from
  794. <http://www.tldp.org/docs.html#howto>.
  795. To compile this driver as a module, choose M here: the
  796. module will be called NCR53c406.
  797. config SCSI_NCR_D700
  798. tristate "NCR Dual 700 MCA SCSI support"
  799. depends on MCA && SCSI
  800. select SCSI_SPI_ATTRS
  801. help
  802. This is a driver for the MicroChannel Dual 700 card produced by
  803. NCR and commonly used in 345x/35xx/4100 class machines. It always
  804. tries to negotiate sync and uses tag command queueing.
  805. Unless you have an NCR manufactured machine, the chances are that
  806. you do not have this SCSI card, so say N.
  807. config SCSI_LASI700
  808. tristate "HP Lasi SCSI support for 53c700/710"
  809. depends on GSC && SCSI
  810. select SCSI_SPI_ATTRS
  811. help
  812. This is a driver for the SCSI controller in the Lasi chip found in
  813. many PA-RISC workstations & servers. If you do not know whether you
  814. have a Lasi chip, it is safe to say "Y" here.
  815. config 53C700_LE_ON_BE
  816. bool
  817. depends on SCSI_LASI700
  818. default y
  819. config SCSI_STEX
  820. tristate "Promise SuperTrak EX Series support"
  821. depends on PCI && SCSI
  822. ---help---
  823. This driver supports Promise SuperTrak EX series storage controllers.
  824. Promise provides Linux RAID configuration utility for these
  825. controllers. Please visit <http://www.promise.com> to download.
  826. To compile this driver as a module, choose M here: the
  827. module will be called stex.
  828. config SCSI_SYM53C8XX_2
  829. tristate "SYM53C8XX Version 2 SCSI support"
  830. depends on PCI && SCSI
  831. select SCSI_SPI_ATTRS
  832. ---help---
  833. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  834. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  835. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  836. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  837. controllers; you need to use the Fusion MPT driver for that.
  838. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  839. information.
  840. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  841. int "DMA addressing mode"
  842. depends on SCSI_SYM53C8XX_2
  843. default "1"
  844. ---help---
  845. This option only applies to PCI-SCSI chips that are PCI DAC
  846. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  847. When set to 0, the driver will program the chip to only perform
  848. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  849. to addresses up to 1TB. When set to 2, the driver supports the
  850. full 64-bit DMA address range, but can only address 16 segments
  851. of 4 GB each. This limits the total addressable range to 64 GB.
  852. Most machines with less than 4GB of memory should use a setting
  853. of 0 for best performance. If your machine has 4GB of memory
  854. or more, you should set this option to 1 (the default).
  855. The still experimental value 2 (64 bit DMA addressing with 16
  856. x 4GB segments limitation) can be used on systems that require
  857. PCI address bits past bit 39 to be set for the addressing of
  858. memory using PCI DAC cycles.
  859. config SCSI_SYM53C8XX_DEFAULT_TAGS
  860. int "Default tagged command queue depth"
  861. depends on SCSI_SYM53C8XX_2
  862. default "16"
  863. help
  864. This is the default value of the command queue depth the
  865. driver will announce to the generic SCSI layer for devices
  866. that support tagged command queueing. This value can be changed
  867. from the boot command line. This is a soft limit that cannot
  868. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  869. config SCSI_SYM53C8XX_MAX_TAGS
  870. int "Maximum number of queued commands"
  871. depends on SCSI_SYM53C8XX_2
  872. default "64"
  873. help
  874. This option allows you to specify the maximum number of commands
  875. that can be queued to any device, when tagged command queuing is
  876. possible. The driver supports up to 256 queued commands per device.
  877. This value is used as a compiled-in hard limit.
  878. config SCSI_SYM53C8XX_MMIO
  879. bool "Use memory mapped IO"
  880. depends on SCSI_SYM53C8XX_2
  881. default y
  882. help
  883. Memory mapped IO is faster than Port IO. Most people should
  884. answer Y here, but some machines may have problems. If you have
  885. to answer N here, please report the problem to the maintainer.
  886. config SCSI_IPR
  887. tristate "IBM Power Linux RAID adapter support"
  888. depends on PCI && SCSI && ATA
  889. select FW_LOADER
  890. ---help---
  891. This driver supports the IBM Power Linux family RAID adapters.
  892. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  893. as IBM iSeries 5702, 5703, 5709, and 570A.
  894. config SCSI_IPR_TRACE
  895. bool "enable driver internal trace"
  896. depends on SCSI_IPR
  897. default y
  898. help
  899. If you say Y here, the driver will trace all commands issued
  900. to the adapter. Performance impact is minimal. Trace can be
  901. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  902. config SCSI_IPR_DUMP
  903. bool "enable adapter dump support"
  904. depends on SCSI_IPR
  905. default y
  906. help
  907. If you say Y here, the driver will support adapter crash dump.
  908. If you enable this support, the iprdump daemon can be used
  909. to capture adapter failure analysis information.
  910. config SCSI_ZALON
  911. tristate "Zalon SCSI support"
  912. depends on GSC && SCSI
  913. select SCSI_SPI_ATTRS
  914. help
  915. The Zalon is a GSC/HSC bus interface chip that sits between the
  916. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  917. C110, J200, J210 and some D, K & R-class machines. It's also
  918. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  919. Say Y here if you have one of these machines or cards.
  920. config SCSI_NCR_Q720
  921. tristate "NCR Quad 720 MCA SCSI support"
  922. depends on MCA && SCSI
  923. select SCSI_SPI_ATTRS
  924. help
  925. This is a driver for the MicroChannel Quad 720 card produced by
  926. NCR and commonly used in 345x/35xx/4100 class machines. It always
  927. tries to negotiate sync and uses tag command queueing.
  928. Unless you have an NCR manufactured machine, the chances are that
  929. you do not have this SCSI card, so say N.
  930. config SCSI_NCR53C8XX_DEFAULT_TAGS
  931. int "default tagged command queue depth"
  932. depends on SCSI_ZALON || SCSI_NCR_Q720
  933. default "8"
  934. ---help---
  935. "Tagged command queuing" is a feature of SCSI-2 which improves
  936. performance: the host adapter can send several SCSI commands to a
  937. device's queue even if previous commands haven't finished yet.
  938. Because the device is intelligent, it can optimize its operations
  939. (like head positioning) based on its own request queue. Some SCSI
  940. devices don't implement this properly; if you want to disable this
  941. feature, enter 0 or 1 here (it doesn't matter which).
  942. The default value is 8 and should be supported by most hard disks.
  943. This value can be overridden from the boot command line using the
  944. 'tags' option as follows (example):
  945. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  946. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  947. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  948. The normal answer therefore is to go with the default 8 and to use
  949. a boot command line option for devices that need to use a different
  950. command queue depth.
  951. There is no safe option other than using good SCSI devices.
  952. config SCSI_NCR53C8XX_MAX_TAGS
  953. int "maximum number of queued commands"
  954. depends on SCSI_ZALON || SCSI_NCR_Q720
  955. default "32"
  956. ---help---
  957. This option allows you to specify the maximum number of commands
  958. that can be queued to any device, when tagged command queuing is
  959. possible. The default value is 32. Minimum is 2, maximum is 64.
  960. Modern hard disks are able to support 64 tags and even more, but
  961. do not seem to be faster when more than 32 tags are being used.
  962. So, the normal answer here is to go with the default value 32 unless
  963. you are using very large hard disks with large cache (>= 1 MB) that
  964. are able to take advantage of more than 32 tagged commands.
  965. There is no safe option and the default answer is recommended.
  966. config SCSI_NCR53C8XX_SYNC
  967. int "synchronous transfers frequency in MHz"
  968. depends on SCSI_ZALON || SCSI_NCR_Q720
  969. default "20"
  970. ---help---
  971. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  972. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  973. are respectively the maximum data transfer rates in mega-transfers
  974. per second for each class. For example, a FAST-20 Wide 16 device is
  975. able to transfer data at 20 million 16 bit packets per second for a
  976. total rate of 40 MB/s.
  977. You may specify 0 if you want to only use asynchronous data
  978. transfers. This is the safest and slowest option. Otherwise, specify
  979. a value between 5 and 80, depending on the capability of your SCSI
  980. controller. The higher the number, the faster the data transfer.
  981. Note that 80 should normally be ok since the driver decreases the
  982. value automatically according to the controller's capabilities.
  983. Your answer to this question is ignored for controllers with NVRAM,
  984. since the driver will get this information from the user set-up. It
  985. also can be overridden using a boot setup option, as follows
  986. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  987. for FAST-20 synchronous data transfer (20 mega-transfers per
  988. second).
  989. The normal answer therefore is not to go with the default but to
  990. select the maximum value 80 allowing the driver to use the maximum
  991. value supported by each controller. If this causes problems with
  992. your SCSI devices, you should come back and decrease the value.
  993. There is no safe option other than using good cabling, right
  994. terminations and SCSI conformant devices.
  995. config SCSI_NCR53C8XX_PROFILE
  996. bool "enable profiling"
  997. depends on SCSI_ZALON || SCSI_NCR_Q720
  998. help
  999. This option allows you to enable profiling information gathering.
  1000. These statistics are not very accurate due to the low frequency
  1001. of the kernel clock (100 Hz on i386) and have performance impact
  1002. on systems that use very fast devices.
  1003. The normal answer therefore is N.
  1004. config SCSI_NCR53C8XX_NO_DISCONNECT
  1005. bool "not allow targets to disconnect"
  1006. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  1007. help
  1008. This option is only provided for safety if you suspect some SCSI
  1009. device of yours to not support properly the target-disconnect
  1010. feature. In that case, you would say Y here. In general however, to
  1011. not allow targets to disconnect is not reasonable if there is more
  1012. than 1 device on a SCSI bus. The normal answer therefore is N.
  1013. config SCSI_MCA_53C9X
  1014. tristate "NCR MCA 53C9x SCSI support"
  1015. depends on MCA_LEGACY && SCSI && BROKEN_ON_SMP
  1016. help
  1017. Some MicroChannel machines, notably the NCR 35xx line, use a SCSI
  1018. controller based on the NCR 53C94. This driver will allow use of
  1019. the controller on the 3550, and very possibly others.
  1020. To compile this driver as a module, choose M here: the
  1021. module will be called mca_53c9x.
  1022. config SCSI_PAS16
  1023. tristate "PAS16 SCSI support"
  1024. depends on ISA && SCSI
  1025. select SCSI_SPI_ATTRS
  1026. ---help---
  1027. This is support for a SCSI host adapter. It is explained in section
  1028. 3.10 of the SCSI-HOWTO, available from
  1029. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1030. of the box, you may have to change some settings in
  1031. <file:drivers/scsi/pas16.h>.
  1032. To compile this driver as a module, choose M here: the
  1033. module will be called pas16.
  1034. config SCSI_PSI240I
  1035. tristate "PSI240i support"
  1036. depends on ISA && SCSI
  1037. help
  1038. This is support for the PSI240i EIDE interface card which acts as a
  1039. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1040. <http://www.tldp.org/docs.html#howto>.
  1041. To compile this driver as a module, choose M here: the
  1042. module will be called psi240i.
  1043. config SCSI_QLOGIC_FAS
  1044. tristate "Qlogic FAS SCSI support"
  1045. depends on ISA && SCSI
  1046. ---help---
  1047. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1048. FastSCSI! cards as well as any other card based on the FASXX chip
  1049. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1050. This driver does NOT support the PCI versions of these cards. The
  1051. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1052. SCSI support"), below.
  1053. Information about this driver is contained in
  1054. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1055. SCSI-HOWTO, available from
  1056. <http://www.tldp.org/docs.html#howto>.
  1057. To compile this driver as a module, choose M here: the
  1058. module will be called qlogicfas.
  1059. config SCSI_QLOGIC_FC_FIRMWARE
  1060. bool "Include loadable firmware in driver"
  1061. depends on SCSI_QLOGIC_FC
  1062. help
  1063. Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
  1064. expanded LUN addressing and FcTape (FCP-2) support, in the
  1065. qlogicfc driver. This is required on some platforms.
  1066. config SCSI_QLOGIC_1280
  1067. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1068. depends on PCI && SCSI
  1069. help
  1070. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1071. To compile this driver as a module, choose M here: the
  1072. module will be called qla1280.
  1073. config SCSI_QLOGICPTI
  1074. tristate "PTI Qlogic, ISP Driver"
  1075. depends on SBUS && SCSI
  1076. help
  1077. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1078. controllers are known under Solaris as qpti and in the openprom as
  1079. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1080. driven by a different driver.
  1081. To compile this driver as a module, choose M here: the
  1082. module will be called qlogicpti.
  1083. source "drivers/scsi/qla2xxx/Kconfig"
  1084. source "drivers/scsi/qla4xxx/Kconfig"
  1085. config SCSI_LPFC
  1086. tristate "Emulex LightPulse Fibre Channel Support"
  1087. depends on PCI && SCSI
  1088. select SCSI_FC_ATTRS
  1089. help
  1090. This lpfc driver supports the Emulex LightPulse
  1091. Family of Fibre Channel PCI host adapters.
  1092. config SCSI_SEAGATE
  1093. tristate "Seagate ST-02 and Future Domain TMC-8xx SCSI support"
  1094. depends on X86 && ISA && SCSI
  1095. ---help---
  1096. These are 8-bit SCSI controllers; the ST-01 is also supported by
  1097. this driver. It is explained in section 3.9 of the SCSI-HOWTO,
  1098. available from <http://www.tldp.org/docs.html#howto>. If it
  1099. doesn't work out of the box, you may have to change some macros at
  1100. compiletime, which are described in <file:drivers/scsi/seagate.c>.
  1101. To compile this driver as a module, choose M here: the
  1102. module will be called seagate.
  1103. # definitely looks not 64bit safe:
  1104. config SCSI_SIM710
  1105. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1106. depends on (EISA || MCA) && SCSI
  1107. select SCSI_SPI_ATTRS
  1108. ---help---
  1109. This driver for NCR53c710 based SCSI host adapters.
  1110. It currently supports Compaq EISA cards and NCR MCA cards
  1111. config 53C700_IO_MAPPED
  1112. bool
  1113. depends on SCSI_SIM710
  1114. default y
  1115. config SCSI_SYM53C416
  1116. tristate "Symbios 53c416 SCSI support"
  1117. depends on ISA && SCSI
  1118. ---help---
  1119. This is support for the sym53c416 SCSI host adapter, the SCSI
  1120. adapter that comes with some HP scanners. This driver requires that
  1121. the sym53c416 is configured first using some sort of PnP
  1122. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1123. are using isapnp then you need to compile this driver as a module
  1124. and then load it using insmod after isapnp has run. The parameters
  1125. of the configured card(s) should be passed to the driver. The format
  1126. is:
  1127. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1128. To compile this driver as a module, choose M here: the
  1129. module will be called sym53c416.
  1130. config SCSI_DC395x
  1131. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1132. depends on PCI && SCSI && EXPERIMENTAL
  1133. ---help---
  1134. This driver supports PCI SCSI host adapters based on the ASIC
  1135. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1136. This driver works, but is still in experimental status. So better
  1137. have a bootable disk and a backup in case of emergency.
  1138. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1139. To compile this driver as a module, choose M here: the
  1140. module will be called dc395x.
  1141. config SCSI_DC390T
  1142. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1143. depends on PCI && SCSI
  1144. ---help---
  1145. This driver supports PCI SCSI host adapters based on the Am53C974A
  1146. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1147. PCscsi/PCnet (Am53/79C974) solutions.
  1148. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1149. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1150. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1151. To compile this driver as a module, choose M here: the
  1152. module will be called tmscsim.
  1153. config SCSI_T128
  1154. tristate "Trantor T128/T128F/T228 SCSI support"
  1155. depends on ISA && SCSI
  1156. select SCSI_SPI_ATTRS
  1157. ---help---
  1158. This is support for a SCSI host adapter. It is explained in section
  1159. 3.11 of the SCSI-HOWTO, available from
  1160. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1161. of the box, you may have to change some settings in
  1162. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1163. Adaptec, and some former Trantor products are being sold under the
  1164. Adaptec name.
  1165. To compile this driver as a module, choose M here: the
  1166. module will be called t128.
  1167. config SCSI_U14_34F
  1168. tristate "UltraStor 14F/34F support"
  1169. depends on ISA && SCSI && ISA_DMA_API
  1170. ---help---
  1171. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1172. The source at <file:drivers/scsi/u14-34f.c> contains some
  1173. information about this hardware. If the driver doesn't work out of
  1174. the box, you may have to change some settings in
  1175. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1176. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1177. another driver for the same hardware: "UltraStor SCSI support",
  1178. below. You should say Y to both only if you want 24F support as
  1179. well.
  1180. To compile this driver as a module, choose M here: the
  1181. module will be called u14-34f.
  1182. config SCSI_U14_34F_TAGGED_QUEUE
  1183. bool "enable tagged command queueing"
  1184. depends on SCSI_U14_34F
  1185. help
  1186. This is a feature of SCSI-2 which improves performance: the host
  1187. adapter can send several SCSI commands to a device's queue even if
  1188. previous commands haven't finished yet.
  1189. This is equivalent to the "u14-34f=tc:y" boot option.
  1190. config SCSI_U14_34F_LINKED_COMMANDS
  1191. bool "enable elevator sorting"
  1192. depends on SCSI_U14_34F
  1193. help
  1194. This option enables elevator sorting for all probed SCSI disks and
  1195. CD-ROMs. It definitely reduces the average seek distance when doing
  1196. random seeks, but this does not necessarily result in a noticeable
  1197. performance improvement: your mileage may vary...
  1198. This is equivalent to the "u14-34f=lc:y" boot option.
  1199. config SCSI_U14_34F_MAX_TAGS
  1200. int "maximum number of queued commands"
  1201. depends on SCSI_U14_34F
  1202. default "8"
  1203. help
  1204. This specifies how many SCSI commands can be maximally queued for
  1205. each probed SCSI device. You should reduce the default value of 8
  1206. only if you have disks with buggy or limited tagged command support.
  1207. Minimum is 2 and maximum is 14. This value is also the window size
  1208. used by the elevator sorting option above. The effective value used
  1209. by the driver for each probed SCSI device is reported at boot time.
  1210. This is equivalent to the "u14-34f=mq:8" boot option.
  1211. config SCSI_ULTRASTOR
  1212. tristate "UltraStor SCSI support"
  1213. depends on X86 && ISA && SCSI
  1214. ---help---
  1215. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1216. adapter family. This driver is explained in section 3.12 of the
  1217. SCSI-HOWTO, available from
  1218. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1219. of the box, you may have to change some settings in
  1220. <file:drivers/scsi/ultrastor.h>.
  1221. Note that there is also another driver for the same hardware:
  1222. "UltraStor 14F/34F support", above.
  1223. To compile this driver as a module, choose M here: the
  1224. module will be called ultrastor.
  1225. config SCSI_NSP32
  1226. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1227. depends on PCI && SCSI && !64BIT
  1228. help
  1229. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1230. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1231. <http://www.tldp.org/docs.html#howto>.
  1232. To compile this driver as a module, choose M here: the
  1233. module will be called nsp32.
  1234. config SCSI_DEBUG
  1235. tristate "SCSI debugging host simulator"
  1236. depends on SCSI
  1237. help
  1238. This is a host adapter simulator that can simulate multiple hosts
  1239. each with multiple dummy SCSI devices (disks). It defaults to one
  1240. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1241. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1242. dummy disks are simulated, they share the same kernel RAM for
  1243. their storage. See <http://www.torque.net/sg/sdebug.html> for more
  1244. information. This driver is primarily of use to those testing the
  1245. SCSI and block subsystems. If unsure, say N.
  1246. config SCSI_MESH
  1247. tristate "MESH (Power Mac internal SCSI) support"
  1248. depends on PPC32 && PPC_PMAC && SCSI
  1249. help
  1250. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1251. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1252. other Power Macintoshes do). Say Y to include support for this SCSI
  1253. adaptor.
  1254. To compile this driver as a module, choose M here: the
  1255. module will be called mesh.
  1256. config SCSI_MESH_SYNC_RATE
  1257. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1258. depends on SCSI_MESH
  1259. default "5"
  1260. help
  1261. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1262. drives a bus which is entirely internal to the machine (such as the
  1263. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1264. operation at up to 10 MB/s. On machines where the SCSI bus
  1265. controlled by the MESH can have external devices connected, it is
  1266. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1267. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1268. to disable synchronous operation.
  1269. config SCSI_MESH_RESET_DELAY_MS
  1270. int "initial bus reset delay (ms) (0 = no reset)"
  1271. depends on SCSI_MESH
  1272. default "4000"
  1273. config SCSI_MAC53C94
  1274. tristate "53C94 (Power Mac external SCSI) support"
  1275. depends on PPC32 && PPC_PMAC && SCSI
  1276. help
  1277. On Power Macintoshes (and clones) with two SCSI buses, the external
  1278. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1279. machines which only have one SCSI bus, such as the 7200, also use
  1280. the 53C94. Say Y to include support for the 53C94.
  1281. To compile this driver as a module, choose M here: the
  1282. module will be called mac53c94.
  1283. source "drivers/scsi/arm/Kconfig"
  1284. config JAZZ_ESP
  1285. bool "MIPS JAZZ FAS216 SCSI support"
  1286. depends on MACH_JAZZ && SCSI
  1287. help
  1288. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1289. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1290. systems.
  1291. config A3000_SCSI
  1292. tristate "A3000 WD33C93A support"
  1293. depends on AMIGA && SCSI
  1294. help
  1295. If you have an Amiga 3000 and have SCSI devices connected to the
  1296. built-in SCSI controller, say Y. Otherwise, say N.
  1297. To compile this driver as a module, choose M here: the
  1298. module will be called wd33c93.
  1299. config A2091_SCSI
  1300. tristate "A2091/A590 WD33C93A support"
  1301. depends on ZORRO && SCSI
  1302. help
  1303. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1304. say N.
  1305. To compile this driver as a module, choose M here: the
  1306. module will be called wd33c93.
  1307. config GVP11_SCSI
  1308. tristate "GVP Series II WD33C93A support"
  1309. depends on ZORRO && SCSI
  1310. ---help---
  1311. If you have a Great Valley Products Series II SCSI controller,
  1312. answer Y. Also say Y if you have a later model of GVP SCSI
  1313. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1314. answer N. This driver does NOT work for the T-Rex series of
  1315. accelerators from TekMagic and GVP-M.
  1316. To compile this driver as a module, choose M here: the
  1317. module will be called gvp11.
  1318. config CYBERSTORM_SCSI
  1319. tristate "CyberStorm SCSI support"
  1320. depends on ZORRO && SCSI
  1321. help
  1322. If you have an Amiga with an original (MkI) Phase5 Cyberstorm
  1323. accelerator board and the optional Cyberstorm SCSI controller,
  1324. answer Y. Otherwise, say N.
  1325. config CYBERSTORMII_SCSI
  1326. tristate "CyberStorm Mk II SCSI support"
  1327. depends on ZORRO && SCSI
  1328. help
  1329. If you have an Amiga with a Phase5 Cyberstorm MkII accelerator board
  1330. and the optional Cyberstorm SCSI controller, say Y. Otherwise,
  1331. answer N.
  1332. config BLZ2060_SCSI
  1333. tristate "Blizzard 2060 SCSI support"
  1334. depends on ZORRO && SCSI
  1335. help
  1336. If you have an Amiga with a Phase5 Blizzard 2060 accelerator board
  1337. and want to use the onboard SCSI controller, say Y. Otherwise,
  1338. answer N.
  1339. config BLZ1230_SCSI
  1340. tristate "Blizzard 1230IV/1260 SCSI support"
  1341. depends on ZORRO && SCSI
  1342. help
  1343. If you have an Amiga 1200 with a Phase5 Blizzard 1230IV or Blizzard
  1344. 1260 accelerator, and the optional SCSI module, say Y. Otherwise,
  1345. say N.
  1346. config FASTLANE_SCSI
  1347. tristate "Fastlane SCSI support"
  1348. depends on ZORRO && SCSI
  1349. help
  1350. If you have the Phase5 Fastlane Z3 SCSI controller, or plan to use
  1351. one in the near future, say Y to this question. Otherwise, say N.
  1352. config SCSI_AMIGA7XX
  1353. bool "Amiga NCR53c710 SCSI support (EXPERIMENTAL)"
  1354. depends on AMIGA && SCSI && EXPERIMENTAL && BROKEN
  1355. help
  1356. Support for various NCR53c710-based SCSI controllers on the Amiga.
  1357. This includes:
  1358. - the builtin SCSI controller on the Amiga 4000T,
  1359. - the Amiga 4091 Zorro III SCSI-2 controller,
  1360. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1361. (info at
  1362. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1363. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1364. accelerator card for the Amiga 1200,
  1365. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1366. Note that all of the above SCSI controllers, except for the builtin
  1367. SCSI controller on the Amiga 4000T, reside on the Zorro expansion
  1368. bus, so you also have to enable Zorro bus support if you want to use
  1369. them.
  1370. config OKTAGON_SCSI
  1371. tristate "BSC Oktagon SCSI support (EXPERIMENTAL)"
  1372. depends on ZORRO && SCSI && EXPERIMENTAL
  1373. help
  1374. If you have the BSC Oktagon SCSI disk controller for the Amiga, say
  1375. Y to this question. If you're in doubt about whether you have one,
  1376. see the picture at
  1377. <http://amiga.resource.cx/exp/search.pl?product=oktagon>.
  1378. config ATARI_SCSI
  1379. tristate "Atari native SCSI support"
  1380. depends on ATARI && SCSI && BROKEN
  1381. select SCSI_SPI_ATTRS
  1382. ---help---
  1383. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1384. Falcon, ...) say Y to get it supported. Of course also, if you have
  1385. a compatible SCSI controller (e.g. for Medusa).
  1386. To compile this driver as a module, choose M here: the
  1387. module will be called atari_scsi.
  1388. This driver supports both styles of NCR integration into the
  1389. system: the TT style (separate DMA), and the Falcon style (via
  1390. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1391. in the Hades (without DMA).
  1392. config ATARI_SCSI_TOSHIBA_DELAY
  1393. bool "Long delays for Toshiba CD-ROMs"
  1394. depends on ATARI_SCSI
  1395. help
  1396. This option increases the delay after a SCSI arbitration to
  1397. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1398. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1399. would impact performance a bit, so say N.
  1400. config ATARI_SCSI_RESET_BOOT
  1401. bool "Reset SCSI-devices at boottime"
  1402. depends on ATARI_SCSI
  1403. help
  1404. Reset the devices on your Atari whenever it boots. This makes the
  1405. boot process fractionally longer but may assist recovery from errors
  1406. that leave the devices with SCSI operations partway completed.
  1407. config TT_DMA_EMUL
  1408. bool "Hades SCSI DMA emulator"
  1409. depends on ATARI_SCSI && HADES
  1410. help
  1411. This option enables code which emulates the TT SCSI DMA chip on the
  1412. Hades. This increases the SCSI transfer rates at least ten times
  1413. compared to PIO transfers.
  1414. config MAC_SCSI
  1415. bool "Macintosh NCR5380 SCSI"
  1416. depends on MAC && SCSI=y
  1417. select SCSI_SPI_ATTRS
  1418. help
  1419. This is the NCR 5380 SCSI controller included on most of the 68030
  1420. based Macintoshes. If you have one of these say Y and read the
  1421. SCSI-HOWTO, available from
  1422. <http://www.tldp.org/docs.html#howto>.
  1423. config SCSI_MAC_ESP
  1424. tristate "Macintosh NCR53c9[46] SCSI"
  1425. depends on MAC && SCSI
  1426. help
  1427. This is the NCR 53c9x SCSI controller found on most of the 68040
  1428. based Macintoshes. If you have one of these say Y and read the
  1429. SCSI-HOWTO, available from
  1430. <http://www.tldp.org/docs.html#howto>.
  1431. To compile this driver as a module, choose M here: the
  1432. module will be called mac_esp.
  1433. config MVME147_SCSI
  1434. bool "WD33C93 SCSI driver for MVME147"
  1435. depends on MVME147 && SCSI=y
  1436. select SCSI_SPI_ATTRS
  1437. help
  1438. Support for the on-board SCSI controller on the Motorola MVME147
  1439. single-board computer.
  1440. config MVME16x_SCSI
  1441. bool "NCR53C710 SCSI driver for MVME16x"
  1442. depends on MVME16x && SCSI && BROKEN
  1443. select SCSI_SPI_ATTRS
  1444. help
  1445. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1446. SCSI controller chip. Almost everyone using one of these boards
  1447. will want to say Y to this question.
  1448. config BVME6000_SCSI
  1449. bool "NCR53C710 SCSI driver for BVME6000"
  1450. depends on BVME6000 && SCSI && BROKEN
  1451. select SCSI_SPI_ATTRS
  1452. help
  1453. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1454. SCSI controller chip. Almost everyone using one of these boards
  1455. will want to say Y to this question.
  1456. config SCSI_NCR53C7xx_FAST
  1457. bool "allow FAST-SCSI [10MHz]"
  1458. depends on SCSI_AMIGA7XX || MVME16x_SCSI || BVME6000_SCSI
  1459. help
  1460. This will enable 10MHz FAST-SCSI transfers with your host
  1461. adapter. Some systems have problems with that speed, so it's safest
  1462. to say N here.
  1463. config SUN3_SCSI
  1464. tristate "Sun3 NCR5380 SCSI"
  1465. depends on SUN3 && SCSI
  1466. select SCSI_SPI_ATTRS
  1467. help
  1468. This option will enable support for the OBIO (onboard io) NCR5380
  1469. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1470. "Sun3" type VME scsi controllers also based on the NCR5380.
  1471. General Linux information on the Sun 3 series (now discontinued)
  1472. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1473. config SUN3X_ESP
  1474. bool "Sun3x ESP SCSI"
  1475. depends on SUN3X && SCSI=y
  1476. help
  1477. The ESP was an on-board SCSI controller used on Sun 3/80
  1478. machines. Say Y here to compile in support for it.
  1479. config SCSI_SUNESP
  1480. tristate "Sparc ESP Scsi Driver"
  1481. depends on SBUS && SCSI
  1482. help
  1483. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1484. chipset is present in most SPARC SBUS-based computers.
  1485. To compile this driver as a module, choose M here: the
  1486. module will be called esp.
  1487. # bool 'Cyberstorm Mk III SCSI support (EXPERIMENTAL)' CONFIG_CYBERSTORMIII_SCSI
  1488. config ZFCP
  1489. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1490. depends on S390 && QDIO && SCSI
  1491. select SCSI_FC_ATTRS
  1492. help
  1493. If you want to access SCSI devices attached to your IBM eServer
  1494. zSeries by means of Fibre Channel interfaces say Y.
  1495. For details please refer to the documentation provided by IBM at
  1496. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1497. This driver is also available as a module. This module will be
  1498. called zfcp. If you want to compile it as a module, say M here
  1499. and read <file:Documentation/modules.txt>.
  1500. config SCSI_SRP
  1501. tristate "SCSI RDMA Protocol helper library"
  1502. depends on SCSI && PCI
  1503. select SCSI_TGT
  1504. help
  1505. If you wish to use SRP target drivers, say Y.
  1506. To compile this driver as a module, choose M here: the
  1507. module will be called libsrp.
  1508. endmenu