Kconfig 66 KB

123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229230231232233234235236237238239240241242243244245246247248249250251252253254255256257258259260261262263264265266267268269270271272273274275276277278279280281282283284285286287288289290291292293294295296297298299300301302303304305306307308309310311312313314315316317318319320321322323324325326327328329330331332333334335336337338339340341342343344345346347348349350351352353354355356357358359360361362363364365366367368369370371372373374375376377378379380381382383384385386387388389390391392393394395396397398399400401402403404405406407408409410411412413414415416417418419420421422423424425426427428429430431432433434435436437438439440441442443444445446447448449450451452453454455456457458459460461462463464465466467468469470471472473474475476477478479480481482483484485486487488489490491492493494495496497498499500501502503504505506507508509510511512513514515516517518519520521522523524525526527528529530531532533534535536537538539540541542543544545546547548549550551552553554555556557558559560561562563564565566567568569570571572573574575576577578579580581582583584585586587588589590591592593594595596597598599600601602603604605606607608609610611612613614615616617618619620621622623624625626627628629630631632633634635636637638639640641642643644645646647648649650651652653654655656657658659660661662663664665666667668669670671672673674675676677678679680681682683684685686687688689690691692693694695696697698699700701702703704705706707708709710711712713714715716717718719720721722723724725726727728729730731732733734735736737738739740741742743744745746747748749750751752753754755756757758759760761762763764765766767768769770771772773774775776777778779780781782783784785786787788789790791792793794795796797798799800801802803804805806807808809810811812813814815816817818819820821822823824825826827828829830831832833834835836837838839840841842843844845846847848849850851852853854855856857858859860861862863864865866867868869870871872873874875876877878879880881882883884885886887888889890891892893894895896897898899900901902903904905906907908909910911912913914915916917918919920921922923924925926927928929930931932933934935936937938939940941942943944945946947948949950951952953954955956957958959960961962963964965966967968969970971972973974975976977978979980981982983984985986987988989990991992993994995996997998999100010011002100310041005100610071008100910101011101210131014101510161017101810191020102110221023102410251026102710281029103010311032103310341035103610371038103910401041104210431044104510461047104810491050105110521053105410551056105710581059106010611062106310641065106610671068106910701071107210731074107510761077107810791080108110821083108410851086108710881089109010911092109310941095109610971098109911001101110211031104110511061107110811091110111111121113111411151116111711181119112011211122112311241125112611271128112911301131113211331134113511361137113811391140114111421143114411451146114711481149115011511152115311541155115611571158115911601161116211631164116511661167116811691170117111721173117411751176117711781179118011811182118311841185118611871188118911901191119211931194119511961197119811991200120112021203120412051206120712081209121012111212121312141215121612171218121912201221122212231224122512261227122812291230123112321233123412351236123712381239124012411242124312441245124612471248124912501251125212531254125512561257125812591260126112621263126412651266126712681269127012711272127312741275127612771278127912801281128212831284128512861287128812891290129112921293129412951296129712981299130013011302130313041305130613071308130913101311131213131314131513161317131813191320132113221323132413251326132713281329133013311332133313341335133613371338133913401341134213431344134513461347134813491350135113521353135413551356135713581359136013611362136313641365136613671368136913701371137213731374137513761377137813791380138113821383138413851386138713881389139013911392139313941395139613971398139914001401140214031404140514061407140814091410141114121413141414151416141714181419142014211422142314241425142614271428142914301431143214331434143514361437143814391440144114421443144414451446144714481449145014511452145314541455145614571458145914601461146214631464146514661467146814691470147114721473147414751476147714781479148014811482148314841485148614871488148914901491149214931494149514961497149814991500150115021503150415051506150715081509151015111512151315141515151615171518151915201521152215231524152515261527152815291530153115321533153415351536153715381539154015411542154315441545154615471548154915501551155215531554155515561557155815591560156115621563156415651566156715681569157015711572157315741575157615771578157915801581158215831584158515861587158815891590159115921593159415951596159715981599160016011602160316041605160616071608160916101611161216131614161516161617161816191620162116221623162416251626162716281629163016311632163316341635163616371638163916401641164216431644164516461647164816491650165116521653165416551656165716581659166016611662166316641665166616671668166916701671167216731674167516761677167816791680168116821683168416851686168716881689169016911692169316941695169616971698169917001701170217031704170517061707170817091710171117121713171417151716171717181719172017211722172317241725172617271728172917301731173217331734173517361737173817391740174117421743174417451746174717481749175017511752175317541755175617571758175917601761176217631764176517661767176817691770177117721773177417751776177717781779178017811782178317841785178617871788178917901791179217931794179517961797
  1. menu "SCSI device support"
  2. config RAID_ATTRS
  3. tristate "RAID Transport Class"
  4. default n
  5. depends on BLOCK
  6. ---help---
  7. Provides RAID
  8. config SCSI
  9. tristate "SCSI device support"
  10. depends on BLOCK
  11. select SCSI_DMA if HAS_DMA
  12. ---help---
  13. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  14. any other SCSI device under Linux, say Y and make sure that you know
  15. the name of your SCSI host adapter (the card inside your computer
  16. that "speaks" the SCSI protocol, also called SCSI controller),
  17. because you will be asked for it.
  18. You also need to say Y here if you have a device which speaks
  19. the SCSI protocol. Examples of this include the parallel port
  20. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  21. Channel, FireWire storage and the IDE-SCSI emulation driver.
  22. To compile this driver as a module, choose M here and read
  23. <file:Documentation/scsi/scsi.txt>.
  24. The module will be called scsi_mod.
  25. However, do not compile this as a module if your root file system
  26. (the one containing the directory /) is located on a SCSI device.
  27. config SCSI_DMA
  28. bool
  29. default n
  30. config SCSI_TGT
  31. tristate "SCSI target support"
  32. depends on SCSI && EXPERIMENTAL
  33. ---help---
  34. If you want to use SCSI target mode drivers enable this option.
  35. If you choose M, the module will be called scsi_tgt.
  36. config SCSI_NETLINK
  37. bool
  38. default n
  39. select NET
  40. config SCSI_PROC_FS
  41. bool "legacy /proc/scsi/ support"
  42. depends on SCSI && PROC_FS
  43. default y
  44. ---help---
  45. This option enables support for the various files in
  46. /proc/scsi. In Linux 2.6 this has been superseded by
  47. files in sysfs but many legacy applications rely on this.
  48. If unsure say Y.
  49. comment "SCSI support type (disk, tape, CD-ROM)"
  50. depends on SCSI
  51. config BLK_DEV_SD
  52. tristate "SCSI disk support"
  53. depends on SCSI
  54. ---help---
  55. If you want to use SCSI hard disks, Fibre Channel disks,
  56. Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
  57. USB storage or the SCSI or parallel port version of
  58. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  59. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  60. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  61. CD-ROMs.
  62. To compile this driver as a module, choose M here and read
  63. <file:Documentation/scsi/scsi.txt>.
  64. The module will be called sd_mod.
  65. Do not compile this driver as a module if your root file system
  66. (the one containing the directory /) is located on a SCSI disk.
  67. In this case, do not compile the driver for your SCSI host adapter
  68. (below) as a module either.
  69. config CHR_DEV_ST
  70. tristate "SCSI tape support"
  71. depends on SCSI
  72. ---help---
  73. If you want to use a SCSI tape drive under Linux, say Y and read the
  74. SCSI-HOWTO, available from
  75. <http://www.tldp.org/docs.html#howto>, and
  76. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  77. for SCSI CD-ROMs.
  78. To compile this driver as a module, choose M here and read
  79. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  80. config CHR_DEV_OSST
  81. tristate "SCSI OnStream SC-x0 tape support"
  82. depends on SCSI
  83. ---help---
  84. The OnStream SC-x0 SCSI tape drives cannot be driven by the
  85. standard st driver, but instead need this special osst driver and
  86. use the /dev/osstX char device nodes (major 206). Via usb-storage
  87. and ide-scsi, you may be able to drive the USB-x0 and DI-x0 drives
  88. as well. Note that there is also a second generation of OnStream
  89. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  90. tapes (QIC-157) and can be driven by the standard driver st.
  91. For more information, you may have a look at the SCSI-HOWTO
  92. <http://www.tldp.org/docs.html#howto> and
  93. <file:Documentation/scsi/osst.txt> in the kernel source.
  94. More info on the OnStream driver may be found on
  95. <http://linux1.onstream.nl/test/>
  96. Please also have a look at the standard st docu, as most of it
  97. applies to osst as well.
  98. To compile this driver as a module, choose M here and read
  99. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  100. config BLK_DEV_SR
  101. tristate "SCSI CDROM support"
  102. depends on SCSI
  103. ---help---
  104. If you want to use a SCSI or FireWire CD-ROM under Linux,
  105. say Y and read the SCSI-HOWTO and the CDROM-HOWTO at
  106. <http://www.tldp.org/docs.html#howto>. Also make sure to say
  107. Y or M to "ISO 9660 CD-ROM file system support" later.
  108. To compile this driver as a module, choose M here and read
  109. <file:Documentation/scsi/scsi.txt>.
  110. The module will be called sr_mod.
  111. config BLK_DEV_SR_VENDOR
  112. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  113. depends on BLK_DEV_SR
  114. help
  115. This enables the usage of vendor specific SCSI commands. This is
  116. required to support multisession CDs with old NEC/TOSHIBA cdrom
  117. drives (and HP Writers). If you have such a drive and get the first
  118. session only, try saying Y here; everybody else says N.
  119. config CHR_DEV_SG
  120. tristate "SCSI generic support"
  121. depends on SCSI
  122. ---help---
  123. If you want to use SCSI scanners, synthesizers or CD-writers or just
  124. about anything having "SCSI" in its name other than hard disks,
  125. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  126. directly, so you need some additional software which knows how to
  127. talk to these devices using the SCSI protocol:
  128. For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
  129. writer software look at Cdrtools
  130. (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
  131. and for burning a "disk at once": CDRDAO
  132. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  133. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  134. For other devices, it's possible that you'll have to write the
  135. driver software yourself. Please read the file
  136. <file:Documentation/scsi/scsi-generic.txt> for more information.
  137. To compile this driver as a module, choose M here and read
  138. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  139. If unsure, say N.
  140. config CHR_DEV_SCH
  141. tristate "SCSI media changer support"
  142. depends on SCSI
  143. ---help---
  144. This is a driver for SCSI media changers. Most common devices are
  145. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  146. don't need this for those tiny 6-slot cdrom changers. Media
  147. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  148. If you have such hardware and want to use it with linux, say Y
  149. here. Check <file:Documentation/scsi/scsi-changer.txt> for details.
  150. If you want to compile this as a module ( = code which can be
  151. inserted in and removed from the running kernel whenever you want),
  152. say M here and read <file:Documentation/kbuild/modules.txt> and
  153. <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
  154. If unsure, say N.
  155. config SCSI_ENCLOSURE
  156. tristate "SCSI Enclosure Support"
  157. depends on SCSI && ENCLOSURE_SERVICES
  158. help
  159. Enclosures are devices sitting on or in SCSI backplanes that
  160. manage devices. If you have a disk cage, the chances are that
  161. it has an enclosure device. Selecting this option will just allow
  162. certain enclosure conditions to be reported and is not required.
  163. comment "Some SCSI devices (e.g. CD jukebox) support multiple LUNs"
  164. depends on SCSI
  165. config SCSI_MULTI_LUN
  166. bool "Probe all LUNs on each SCSI device"
  167. depends on SCSI
  168. help
  169. If you have a SCSI device that supports more than one LUN (Logical
  170. Unit Number), e.g. a CD jukebox, and only one LUN is detected, you
  171. can say Y here to force the SCSI driver to probe for multiple LUNs.
  172. A SCSI device with multiple LUNs acts logically like multiple SCSI
  173. devices. The vast majority of SCSI devices have only one LUN, and
  174. so most people can say N here. The max_luns boot/module parameter
  175. allows to override this setting.
  176. config SCSI_CONSTANTS
  177. bool "Verbose SCSI error reporting (kernel size +=12K)"
  178. depends on SCSI
  179. help
  180. The error messages regarding your SCSI hardware will be easier to
  181. understand if you say Y here; it will enlarge your kernel by about
  182. 12 KB. If in doubt, say Y.
  183. config SCSI_LOGGING
  184. bool "SCSI logging facility"
  185. depends on SCSI
  186. ---help---
  187. This turns on a logging facility that can be used to debug a number
  188. of SCSI related problems.
  189. If you say Y here, no logging output will appear by default, but you
  190. can enable logging by saying Y to "/proc file system support" and
  191. "Sysctl support" below and executing the command
  192. echo "scsi log token [level]" > /proc/scsi/scsi
  193. at boot time after the /proc file system has been mounted.
  194. There are a number of things that can be used for 'token' (you can
  195. find them in the source: <file:drivers/scsi/scsi.c>), and this
  196. allows you to select the types of information you want, and the
  197. level allows you to select the level of verbosity.
  198. If you say N here, it may be harder to track down some types of SCSI
  199. problems. If you say Y here your kernel will be somewhat larger, but
  200. there should be no noticeable performance impact as long as you have
  201. logging turned off.
  202. config SCSI_SCAN_ASYNC
  203. bool "Asynchronous SCSI scanning"
  204. depends on SCSI
  205. help
  206. The SCSI subsystem can probe for devices while the rest of the
  207. system continues booting, and even probe devices on different
  208. busses in parallel, leading to a significant speed-up.
  209. If you have built SCSI as modules, enabling this option can
  210. be a problem as the devices may not have been found by the
  211. time your system expects them to have been. You can load the
  212. scsi_wait_scan module to ensure that all scans have completed.
  213. If you build your SCSI drivers into the kernel, then everything
  214. will work fine if you say Y here.
  215. You can override this choice by specifying "scsi_mod.scan=sync"
  216. or async on the kernel's command line.
  217. config SCSI_WAIT_SCAN
  218. tristate
  219. default m
  220. depends on SCSI
  221. depends on MODULES
  222. menu "SCSI Transports"
  223. depends on SCSI
  224. config SCSI_SPI_ATTRS
  225. tristate "Parallel SCSI (SPI) Transport Attributes"
  226. depends on SCSI
  227. help
  228. If you wish to export transport-specific information about
  229. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  230. config SCSI_FC_ATTRS
  231. tristate "FiberChannel Transport Attributes"
  232. depends on SCSI
  233. select SCSI_NETLINK
  234. help
  235. If you wish to export transport-specific information about
  236. each attached FiberChannel device to sysfs, say Y.
  237. Otherwise, say N.
  238. config SCSI_FC_TGT_ATTRS
  239. bool "SCSI target support for FiberChannel Transport Attributes"
  240. depends on SCSI_FC_ATTRS
  241. depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
  242. help
  243. If you want to use SCSI target mode drivers enable this option.
  244. config SCSI_ISCSI_ATTRS
  245. tristate "iSCSI Transport Attributes"
  246. depends on SCSI && NET
  247. help
  248. If you wish to export transport-specific information about
  249. each attached iSCSI device to sysfs, say Y.
  250. Otherwise, say N.
  251. config SCSI_SAS_ATTRS
  252. tristate "SAS Transport Attributes"
  253. depends on SCSI && BLK_DEV_BSG
  254. help
  255. If you wish to export transport-specific information about
  256. each attached SAS device to sysfs, say Y.
  257. source "drivers/scsi/libsas/Kconfig"
  258. config SCSI_SRP_ATTRS
  259. tristate "SRP Transport Attributes"
  260. depends on SCSI
  261. help
  262. If you wish to export transport-specific information about
  263. each attached SRP device to sysfs, say Y.
  264. config SCSI_SRP_TGT_ATTRS
  265. bool "SCSI target support for SRP Transport Attributes"
  266. depends on SCSI_SRP_ATTRS
  267. depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
  268. help
  269. If you want to use SCSI target mode drivers enable this option.
  270. endmenu
  271. menuconfig SCSI_LOWLEVEL
  272. bool "SCSI low-level drivers"
  273. depends on SCSI!=n
  274. default y
  275. if SCSI_LOWLEVEL && SCSI
  276. config ISCSI_TCP
  277. tristate "iSCSI Initiator over TCP/IP"
  278. depends on SCSI && INET
  279. select CRYPTO
  280. select CRYPTO_MD5
  281. select CRYPTO_CRC32C
  282. select SCSI_ISCSI_ATTRS
  283. help
  284. The iSCSI Driver provides a host with the ability to access storage
  285. through an IP network. The driver uses the iSCSI protocol to transport
  286. SCSI requests and responses over a TCP/IP network between the host
  287. (the "initiator") and "targets". Architecturally, the iSCSI driver
  288. combines with the host's TCP/IP stack, network drivers, and Network
  289. Interface Card (NIC) to provide the same functions as a SCSI or a
  290. Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
  291. To compile this driver as a module, choose M here: the
  292. module will be called iscsi_tcp.
  293. The userspace component needed to initialize the driver, documentation,
  294. and sample configuration files can be found here:
  295. http://open-iscsi.org
  296. config SGIWD93_SCSI
  297. tristate "SGI WD93C93 SCSI Driver"
  298. depends on SGI_HAS_WD93 && SCSI
  299. help
  300. If you have a Western Digital WD93 SCSI controller on
  301. an SGI MIPS system, say Y. Otherwise, say N.
  302. config BLK_DEV_3W_XXXX_RAID
  303. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  304. depends on PCI && SCSI
  305. help
  306. 3ware is the only hardware ATA-Raid product in Linux to date.
  307. This card is 2,4, or 8 channel master mode support only.
  308. SCSI support required!!!
  309. <http://www.3ware.com/>
  310. Please read the comments at the top of
  311. <file:drivers/scsi/3w-xxxx.c>.
  312. config SCSI_3W_9XXX
  313. tristate "3ware 9xxx SATA-RAID support"
  314. depends on PCI && SCSI
  315. help
  316. This driver supports the 9000 series 3ware SATA-RAID cards.
  317. <http://www.amcc.com>
  318. Please read the comments at the top of
  319. <file:drivers/scsi/3w-9xxx.c>.
  320. config SCSI_7000FASST
  321. tristate "7000FASST SCSI support"
  322. depends on ISA && SCSI && ISA_DMA_API
  323. select CHECK_SIGNATURE
  324. help
  325. This driver supports the Western Digital 7000 SCSI host adapter
  326. family. Some information is in the source:
  327. <file:drivers/scsi/wd7000.c>.
  328. To compile this driver as a module, choose M here: the
  329. module will be called wd7000.
  330. config SCSI_ACARD
  331. tristate "ACARD SCSI support"
  332. depends on PCI && SCSI
  333. help
  334. This driver supports the ACARD SCSI host adapter.
  335. Support Chip <ATP870 ATP876 ATP880 ATP885>
  336. To compile this driver as a module, choose M here: the
  337. module will be called atp870u.
  338. config SCSI_AHA152X
  339. tristate "Adaptec AHA152X/2825 support"
  340. depends on ISA && SCSI && !64BIT
  341. select SCSI_SPI_ATTRS
  342. select CHECK_SIGNATURE
  343. ---help---
  344. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  345. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  346. must be manually specified in this case.
  347. It is explained in section 3.3 of the SCSI-HOWTO, available from
  348. <http://www.tldp.org/docs.html#howto>. You might also want to
  349. read the file <file:Documentation/scsi/aha152x.txt>.
  350. To compile this driver as a module, choose M here: the
  351. module will be called aha152x.
  352. config SCSI_AHA1542
  353. tristate "Adaptec AHA1542 support"
  354. depends on ISA && SCSI && ISA_DMA_API
  355. ---help---
  356. This is support for a SCSI host adapter. It is explained in section
  357. 3.4 of the SCSI-HOWTO, available from
  358. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  359. purchased by Adaptec, and some former Trantor products are being
  360. sold under the Adaptec name. If it doesn't work out of the box, you
  361. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  362. To compile this driver as a module, choose M here: the
  363. module will be called aha1542.
  364. config SCSI_AHA1740
  365. tristate "Adaptec AHA1740 support"
  366. depends on EISA && SCSI
  367. ---help---
  368. This is support for a SCSI host adapter. It is explained in section
  369. 3.5 of the SCSI-HOWTO, available from
  370. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  371. of the box, you may have to change some settings in
  372. <file:drivers/scsi/aha1740.h>.
  373. To compile this driver as a module, choose M here: the
  374. module will be called aha1740.
  375. config SCSI_AACRAID
  376. tristate "Adaptec AACRAID support"
  377. depends on SCSI && PCI
  378. help
  379. This driver supports a variety of Dell, HP, Adaptec, IBM and
  380. ICP storage products. For a list of supported products, refer
  381. to <file:Documentation/scsi/aacraid.txt>.
  382. To compile this driver as a module, choose M here: the module
  383. will be called aacraid.
  384. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  385. config SCSI_AIC7XXX_OLD
  386. tristate "Adaptec AIC7xxx support (old driver)"
  387. depends on (ISA || EISA || PCI ) && SCSI
  388. help
  389. WARNING This driver is an older aic7xxx driver and is no longer
  390. under active development. Adaptec, Inc. is writing a new driver to
  391. take the place of this one, and it is recommended that whenever
  392. possible, people should use the new Adaptec written driver instead
  393. of this one. This driver will eventually be phased out entirely.
  394. This is support for the various aic7xxx based Adaptec SCSI
  395. controllers. These include the 274x EISA cards; 284x VLB cards;
  396. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  397. motherboard based SCSI controllers from Adaptec. It does not support
  398. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  399. support them. It does not support the 2920 cards from Adaptec that
  400. use the Future Domain SCSI controller chip. For those cards, you
  401. need the "Future Domain 16xx SCSI support" driver.
  402. In general, if the controller is based on an Adaptec SCSI controller
  403. chip from the aic777x series or the aic78xx series, this driver
  404. should work. The only exception is the 7810 which is specifically
  405. not supported (that's the RAID controller chip on the AAA-13x
  406. cards).
  407. Note that the AHA2920 SCSI host adapter is *not* supported by this
  408. driver; choose "Future Domain 16xx SCSI support" instead if you have
  409. one of those.
  410. Information on the configuration options for this controller can be
  411. found by checking the help file for each of the available
  412. configuration options. You should read
  413. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  414. contacting the maintainer with any questions. The SCSI-HOWTO,
  415. available from <http://www.tldp.org/docs.html#howto>, can also
  416. be of great help.
  417. To compile this driver as a module, choose M here: the
  418. module will be called aic7xxx_old.
  419. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  420. source "drivers/scsi/aic94xx/Kconfig"
  421. config SCSI_DPT_I2O
  422. tristate "Adaptec I2O RAID support "
  423. depends on SCSI && PCI && VIRT_TO_BUS
  424. help
  425. This driver supports all of Adaptec's I2O based RAID controllers as
  426. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  427. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  428. To compile this driver as a module, choose M here: the
  429. module will be called dpt_i2o.
  430. config SCSI_ADVANSYS
  431. tristate "AdvanSys SCSI support"
  432. depends on SCSI && VIRT_TO_BUS
  433. depends on ISA || EISA || PCI
  434. help
  435. This is a driver for all SCSI host adapters manufactured by
  436. AdvanSys. It is documented in the kernel source in
  437. <file:drivers/scsi/advansys.c>.
  438. To compile this driver as a module, choose M here: the
  439. module will be called advansys.
  440. config SCSI_IN2000
  441. tristate "Always IN2000 SCSI support"
  442. depends on ISA && SCSI
  443. help
  444. This is support for an ISA bus SCSI host adapter. You'll find more
  445. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  446. out of the box, you may have to change the jumpers for IRQ or
  447. address selection.
  448. To compile this driver as a module, choose M here: the
  449. module will be called in2000.
  450. config SCSI_ARCMSR
  451. tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
  452. depends on PCI && SCSI
  453. help
  454. This driver supports all of ARECA's SATA/SAS RAID controller cards.
  455. This is an ARECA-maintained driver by Erich Chen.
  456. If you have any problems, please mail to: <erich@areca.com.tw>.
  457. Areca supports Linux RAID config tools.
  458. Please link <http://www.areca.com.tw>
  459. To compile this driver as a module, choose M here: the
  460. module will be called arcmsr (modprobe arcmsr).
  461. config SCSI_ARCMSR_AER
  462. bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
  463. depends on SCSI_ARCMSR && PCIEAER
  464. default n
  465. help
  466. The advanced error reporting(AER) capability is "NOT" provided by
  467. ARC1200/1201/1202 SATA RAID controllers cards.
  468. If your card is one of ARC1200/1201/1202, please use the default setting, n.
  469. If your card is other models, you could pick it
  470. on condition that the kernel version is greater than 2.6.19.
  471. This function is maintained driver by Nick Cheng. If you have any
  472. problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
  473. To enable this function, choose Y here.
  474. source "drivers/scsi/megaraid/Kconfig.megaraid"
  475. config SCSI_HPTIOP
  476. tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
  477. depends on SCSI && PCI
  478. help
  479. This option enables support for HighPoint RocketRAID 3xxx/4xxx
  480. controllers.
  481. To compile this driver as a module, choose M here; the module
  482. will be called hptiop. If unsure, say N.
  483. config SCSI_BUSLOGIC
  484. tristate "BusLogic SCSI support"
  485. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
  486. ---help---
  487. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  488. Adapters. Consult the SCSI-HOWTO, available from
  489. <http://www.tldp.org/docs.html#howto>, and the files
  490. <file:Documentation/scsi/BusLogic.txt> and
  491. <file:Documentation/scsi/FlashPoint.txt> for more information.
  492. Note that support for FlashPoint is only available for 32-bit
  493. x86 configurations.
  494. To compile this driver as a module, choose M here: the
  495. module will be called BusLogic.
  496. config SCSI_FLASHPOINT
  497. bool "FlashPoint support"
  498. depends on SCSI_BUSLOGIC && PCI && X86_32
  499. help
  500. This option allows you to add FlashPoint support to the
  501. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  502. substantial, so users of MultiMaster Host Adapters may not
  503. wish to include it.
  504. config SCSI_DMX3191D
  505. tristate "DMX3191D SCSI support"
  506. depends on PCI && SCSI
  507. select SCSI_SPI_ATTRS
  508. help
  509. This is support for Domex DMX3191D SCSI Host Adapters.
  510. To compile this driver as a module, choose M here: the
  511. module will be called dmx3191d.
  512. config SCSI_DTC3280
  513. tristate "DTC3180/3280 SCSI support"
  514. depends on ISA && SCSI
  515. select SCSI_SPI_ATTRS
  516. select CHECK_SIGNATURE
  517. help
  518. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  519. the SCSI-HOWTO, available from
  520. <http://www.tldp.org/docs.html#howto>, and the file
  521. <file:Documentation/scsi/dtc3x80.txt>.
  522. To compile this driver as a module, choose M here: the
  523. module will be called dtc.
  524. config SCSI_EATA
  525. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  526. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  527. ---help---
  528. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  529. ISA and all EISA I/O addresses are probed looking for the "EATA"
  530. signature. The addresses of all the PCI SCSI controllers reported
  531. by the PCI subsystem are probed as well.
  532. You want to read the start of <file:drivers/scsi/eata.c> and the
  533. SCSI-HOWTO, available from
  534. <http://www.tldp.org/docs.html#howto>.
  535. To compile this driver as a module, choose M here: the
  536. module will be called eata.
  537. config SCSI_EATA_TAGGED_QUEUE
  538. bool "enable tagged command queueing"
  539. depends on SCSI_EATA
  540. help
  541. This is a feature of SCSI-2 which improves performance: the host
  542. adapter can send several SCSI commands to a device's queue even if
  543. previous commands haven't finished yet.
  544. This is equivalent to the "eata=tc:y" boot option.
  545. config SCSI_EATA_LINKED_COMMANDS
  546. bool "enable elevator sorting"
  547. depends on SCSI_EATA
  548. help
  549. This option enables elevator sorting for all probed SCSI disks and
  550. CD-ROMs. It definitely reduces the average seek distance when doing
  551. random seeks, but this does not necessarily result in a noticeable
  552. performance improvement: your mileage may vary...
  553. This is equivalent to the "eata=lc:y" boot option.
  554. config SCSI_EATA_MAX_TAGS
  555. int "maximum number of queued commands"
  556. depends on SCSI_EATA
  557. default "16"
  558. help
  559. This specifies how many SCSI commands can be maximally queued for
  560. each probed SCSI device. You should reduce the default value of 16
  561. only if you have disks with buggy or limited tagged command support.
  562. Minimum is 2 and maximum is 62. This value is also the window size
  563. used by the elevator sorting option above. The effective value used
  564. by the driver for each probed SCSI device is reported at boot time.
  565. This is equivalent to the "eata=mq:8" boot option.
  566. config SCSI_EATA_PIO
  567. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  568. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  569. ---help---
  570. This driver supports all EATA-PIO protocol compliant SCSI Host
  571. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  572. host adapters could also use this driver but are discouraged from
  573. doing so, since this driver only supports hard disks and lacks
  574. numerous features. You might want to have a look at the SCSI-HOWTO,
  575. available from <http://www.tldp.org/docs.html#howto>.
  576. To compile this driver as a module, choose M here: the
  577. module will be called eata_pio.
  578. config SCSI_FUTURE_DOMAIN
  579. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  580. depends on (ISA || PCI) && SCSI
  581. select CHECK_SIGNATURE
  582. ---help---
  583. This is support for Future Domain's 16-bit SCSI host adapters
  584. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  585. other adapters based on the Future Domain chipsets (Quantum
  586. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  587. It is explained in section 3.7 of the SCSI-HOWTO, available from
  588. <http://www.tldp.org/docs.html#howto>.
  589. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  590. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  591. controller support"). This Future Domain driver works with the older
  592. Adaptec AHA-2920A boards with a Future Domain chip on them.
  593. To compile this driver as a module, choose M here: the
  594. module will be called fdomain.
  595. config SCSI_FD_MCS
  596. tristate "Future Domain MCS-600/700 SCSI support"
  597. depends on MCA_LEGACY && SCSI
  598. ---help---
  599. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  600. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  601. is identical to the MCS 700 and hence also supported by this driver.
  602. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  603. It supports multiple adapters in the same system.
  604. To compile this driver as a module, choose M here: the
  605. module will be called fd_mcs.
  606. config SCSI_GDTH
  607. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  608. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  609. ---help---
  610. Formerly called GDT SCSI Disk Array Controller Support.
  611. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  612. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  613. in the kernel source in <file:drivers/scsi/gdth.c> and
  614. <file:drivers/scsi/gdth.h>.
  615. To compile this driver as a module, choose M here: the
  616. module will be called gdth.
  617. config SCSI_GENERIC_NCR5380
  618. tristate "Generic NCR5380/53c400 SCSI PIO support"
  619. depends on ISA && SCSI
  620. select SCSI_SPI_ATTRS
  621. ---help---
  622. This is a driver for the old NCR 53c80 series of SCSI controllers
  623. on boards using PIO. Most boards such as the Trantor T130 fit this
  624. category, along with a large number of ISA 8bit controllers shipped
  625. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  626. you should select the specific driver for that card rather than
  627. generic 5380 support.
  628. It is explained in section 3.8 of the SCSI-HOWTO, available from
  629. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  630. of the box, you may have to change some settings in
  631. <file:drivers/scsi/g_NCR5380.h>.
  632. To compile this driver as a module, choose M here: the
  633. module will be called g_NCR5380.
  634. config SCSI_GENERIC_NCR5380_MMIO
  635. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  636. depends on ISA && SCSI
  637. select SCSI_SPI_ATTRS
  638. ---help---
  639. This is a driver for the old NCR 53c80 series of SCSI controllers
  640. on boards using memory mapped I/O.
  641. It is explained in section 3.8 of the SCSI-HOWTO, available from
  642. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  643. of the box, you may have to change some settings in
  644. <file:drivers/scsi/g_NCR5380.h>.
  645. To compile this driver as a module, choose M here: the
  646. module will be called g_NCR5380_mmio.
  647. config SCSI_GENERIC_NCR53C400
  648. bool "Enable NCR53c400 extensions"
  649. depends on SCSI_GENERIC_NCR5380
  650. help
  651. This enables certain optimizations for the NCR53c400 SCSI cards.
  652. You might as well try it out. Note that this driver will only probe
  653. for the Trantor T130B in its default configuration; you might have
  654. to pass a command line option to the kernel at boot time if it does
  655. not detect your card. See the file
  656. <file:Documentation/scsi/g_NCR5380.txt> for details.
  657. config SCSI_IBMMCA
  658. tristate "IBMMCA SCSI support"
  659. depends on MCA && SCSI
  660. ---help---
  661. This is support for the IBM SCSI adapter found in many of the PS/2
  662. series computers. These machines have an MCA bus, so you need to
  663. answer Y to "MCA support" as well and read
  664. <file:Documentation/mca.txt>.
  665. If the adapter isn't found during boot (a common problem for models
  666. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  667. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  668. if that doesn't work check your reference diskette). Owners of
  669. model 95 with a LED-matrix-display can in addition activate some
  670. activity info like under OS/2, but more informative, by setting
  671. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  672. bootparam" or see the documentation of your boot loader about how to
  673. pass options to the kernel.
  674. To compile this driver as a module, choose M here: the
  675. module will be called ibmmca.
  676. config IBMMCA_SCSI_ORDER_STANDARD
  677. bool "Standard SCSI-order"
  678. depends on SCSI_IBMMCA
  679. ---help---
  680. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  681. are assigned to the drive letters, starting with the lowest SCSI-id
  682. (physical number -- pun) to be drive C:, as seen from DOS and
  683. similar operating systems. When looking into papers describing the
  684. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  685. The SCSI-standard follows a hardware-hierarchy which says that id 7
  686. has the highest priority and id 0 the lowest. Therefore, the host
  687. adapters are still today everywhere placed as SCSI-id 7 by default.
  688. In the SCSI-standard, the drive letters express the priority of the
  689. disk. C: should be the hard disk, or a partition on it, with the
  690. highest priority. This must therefore be the disk with the highest
  691. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  692. original definition of the SCSI-standard as also industrial- and
  693. process-control-machines, like VME-CPUs running under realtime-OSes
  694. (e.g. LynxOS, OS9) do.
  695. If you like to run Linux on your MCA-machine with the same
  696. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  697. machine, which is in addition conformant to the SCSI-standard, you
  698. must say Y here. This is also necessary for MCA-Linux users who want
  699. to keep downward compatibility to older releases of the
  700. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  701. June 1997).
  702. If you like to have the lowest SCSI-id assigned as drive C:, as
  703. modern SCSI-BIOSes do, which does not conform to the standard, but
  704. is widespread and common in the PC-world of today, you must say N
  705. here. If unsure, say Y.
  706. config IBMMCA_SCSI_DEV_RESET
  707. bool "Reset SCSI-devices at boottime"
  708. depends on SCSI_IBMMCA
  709. ---help---
  710. By default, SCSI-devices are reset when the machine is powered on.
  711. However, some devices exist, like special-control-devices,
  712. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  713. not reset when switched on. If you say Y here, each device connected
  714. to your SCSI-bus will be issued a reset-command after it has been
  715. probed, while the kernel is booting. This may cause problems with
  716. more modern devices, like hard disks, which do not appreciate these
  717. reset commands, and can cause your system to hang. So say Y only if
  718. you know that one of your older devices needs it; N is the safe
  719. answer.
  720. config SCSI_IPS
  721. tristate "IBM ServeRAID support"
  722. depends on PCI && SCSI
  723. ---help---
  724. This is support for the IBM ServeRAID hardware RAID controllers.
  725. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  726. for more information. If this driver does not work correctly
  727. without modification please contact the author by email at
  728. <ipslinux@adaptec.com>.
  729. To compile this driver as a module, choose M here: the
  730. module will be called ips.
  731. config SCSI_IBMVSCSI
  732. tristate "IBM Virtual SCSI support"
  733. depends on PPC_PSERIES || PPC_ISERIES
  734. select SCSI_SRP_ATTRS
  735. help
  736. This is the IBM POWER Virtual SCSI Client
  737. To compile this driver as a module, choose M here: the
  738. module will be called ibmvscsic.
  739. config SCSI_IBMVSCSIS
  740. tristate "IBM Virtual SCSI Server support"
  741. depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
  742. help
  743. This is the SRP target driver for IBM pSeries virtual environments.
  744. The userspace component needed to initialize the driver and
  745. documentation can be found:
  746. http://stgt.berlios.de/
  747. To compile this driver as a module, choose M here: the
  748. module will be called ibmvstgt.
  749. config SCSI_IBMVFC
  750. tristate "IBM Virtual FC support"
  751. depends on PPC_PSERIES && SCSI
  752. select SCSI_FC_ATTRS
  753. help
  754. This is the IBM POWER Virtual FC Client
  755. To compile this driver as a module, choose M here: the
  756. module will be called ibmvfc.
  757. config SCSI_IBMVFC_TRACE
  758. bool "enable driver internal trace"
  759. depends on SCSI_IBMVFC
  760. default y
  761. help
  762. If you say Y here, the driver will trace all commands issued
  763. to the adapter. Performance impact is minimal. Trace can be
  764. dumped using /sys/class/scsi_host/hostXX/trace.
  765. config SCSI_INITIO
  766. tristate "Initio 9100U(W) support"
  767. depends on PCI && SCSI
  768. help
  769. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  770. read the SCSI-HOWTO, available from
  771. <http://www.tldp.org/docs.html#howto>.
  772. To compile this driver as a module, choose M here: the
  773. module will be called initio.
  774. config SCSI_INIA100
  775. tristate "Initio INI-A100U2W support"
  776. depends on PCI && SCSI
  777. help
  778. This is support for the Initio INI-A100U2W SCSI host adapter.
  779. Please read the SCSI-HOWTO, available from
  780. <http://www.tldp.org/docs.html#howto>.
  781. To compile this driver as a module, choose M here: the
  782. module will be called a100u2w.
  783. config SCSI_PPA
  784. tristate "IOMEGA parallel port (ppa - older drives)"
  785. depends on SCSI && PARPORT_PC
  786. ---help---
  787. This driver supports older versions of IOMEGA's parallel port ZIP
  788. drive (a 100 MB removable media device).
  789. Note that you can say N here if you have the SCSI version of the ZIP
  790. drive: it will be supported automatically if you said Y to the
  791. generic "SCSI disk support", above.
  792. If you have the ZIP Plus drive or a more recent parallel port ZIP
  793. drive (if the supplied cable with the drive is labeled "AutoDetect")
  794. then you should say N here and Y to "IOMEGA parallel port (imm -
  795. newer drives)", below.
  796. For more information about this driver and how to use it you should
  797. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  798. the SCSI-HOWTO, which is available from
  799. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  800. you will still be able to use the parallel port for other tasks,
  801. such as a printer; it is safe to compile both drivers into the
  802. kernel.
  803. To compile this driver as a module, choose M here: the
  804. module will be called ppa.
  805. config SCSI_IMM
  806. tristate "IOMEGA parallel port (imm - newer drives)"
  807. depends on SCSI && PARPORT_PC
  808. ---help---
  809. This driver supports newer versions of IOMEGA's parallel port ZIP
  810. drive (a 100 MB removable media device).
  811. Note that you can say N here if you have the SCSI version of the ZIP
  812. drive: it will be supported automatically if you said Y to the
  813. generic "SCSI disk support", above.
  814. If you have the ZIP Plus drive or a more recent parallel port ZIP
  815. drive (if the supplied cable with the drive is labeled "AutoDetect")
  816. then you should say Y here; if you have an older ZIP drive, say N
  817. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  818. For more information about this driver and how to use it you should
  819. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  820. the SCSI-HOWTO, which is available from
  821. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  822. you will still be able to use the parallel port for other tasks,
  823. such as a printer; it is safe to compile both drivers into the
  824. kernel.
  825. To compile this driver as a module, choose M here: the
  826. module will be called imm.
  827. config SCSI_IZIP_EPP16
  828. bool "ppa/imm option - Use slow (but safe) EPP-16"
  829. depends on SCSI_PPA || SCSI_IMM
  830. ---help---
  831. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  832. allows them to act as expansion buses that can handle up to 64
  833. peripheral devices.
  834. Some parallel port chipsets are slower than their motherboard, and
  835. so we have to control the state of the chipset's FIFO queue every
  836. now and then to avoid data loss. This will be done if you say Y
  837. here.
  838. Generally, saying Y is the safe option and slows things down a bit.
  839. config SCSI_IZIP_SLOW_CTR
  840. bool "ppa/imm option - Assume slow parport control register"
  841. depends on SCSI_PPA || SCSI_IMM
  842. help
  843. Some parallel ports are known to have excessive delays between
  844. changing the parallel port control register and good data being
  845. available on the parallel port data/status register. This option
  846. forces a small delay (1.0 usec to be exact) after changing the
  847. control register to let things settle out. Enabling this option may
  848. result in a big drop in performance but some very old parallel ports
  849. (found in 386 vintage machines) will not work properly.
  850. Generally, saying N is fine.
  851. config SCSI_MVSAS
  852. tristate "Marvell 88SE6440 SAS/SATA support"
  853. depends on PCI && SCSI
  854. select SCSI_SAS_LIBSAS
  855. help
  856. This driver supports Marvell SAS/SATA PCI devices.
  857. To compiler this driver as a module, choose M here: the module
  858. will be called mvsas.
  859. config SCSI_NCR53C406A
  860. tristate "NCR53c406a SCSI support"
  861. depends on ISA && SCSI
  862. help
  863. This is support for the NCR53c406a SCSI host adapter. For user
  864. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  865. in the kernel source. Also read the SCSI-HOWTO, available from
  866. <http://www.tldp.org/docs.html#howto>.
  867. To compile this driver as a module, choose M here: the
  868. module will be called NCR53c406.
  869. config SCSI_NCR_D700
  870. tristate "NCR Dual 700 MCA SCSI support"
  871. depends on MCA && SCSI
  872. select SCSI_SPI_ATTRS
  873. help
  874. This is a driver for the MicroChannel Dual 700 card produced by
  875. NCR and commonly used in 345x/35xx/4100 class machines. It always
  876. tries to negotiate sync and uses tag command queueing.
  877. Unless you have an NCR manufactured machine, the chances are that
  878. you do not have this SCSI card, so say N.
  879. config SCSI_LASI700
  880. tristate "HP Lasi SCSI support for 53c700/710"
  881. depends on GSC && SCSI
  882. select SCSI_SPI_ATTRS
  883. help
  884. This is a driver for the SCSI controller in the Lasi chip found in
  885. many PA-RISC workstations & servers. If you do not know whether you
  886. have a Lasi chip, it is safe to say "Y" here.
  887. config SCSI_SNI_53C710
  888. tristate "SNI RM SCSI support for 53c710"
  889. depends on SNI_RM && SCSI
  890. select SCSI_SPI_ATTRS
  891. select 53C700_LE_ON_BE
  892. help
  893. This is a driver for the onboard SCSI controller found in older
  894. SNI RM workstations & servers.
  895. config 53C700_LE_ON_BE
  896. bool
  897. depends on SCSI_LASI700
  898. default y
  899. config SCSI_STEX
  900. tristate "Promise SuperTrak EX Series support"
  901. depends on PCI && SCSI
  902. ---help---
  903. This driver supports Promise SuperTrak EX series storage controllers.
  904. Promise provides Linux RAID configuration utility for these
  905. controllers. Please visit <http://www.promise.com> to download.
  906. To compile this driver as a module, choose M here: the
  907. module will be called stex.
  908. config 53C700_BE_BUS
  909. bool
  910. depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
  911. default y
  912. config SCSI_SYM53C8XX_2
  913. tristate "SYM53C8XX Version 2 SCSI support"
  914. depends on PCI && SCSI
  915. select SCSI_SPI_ATTRS
  916. ---help---
  917. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  918. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  919. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  920. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  921. controllers; you need to use the Fusion MPT driver for that.
  922. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  923. information.
  924. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  925. int "DMA addressing mode"
  926. depends on SCSI_SYM53C8XX_2
  927. default "1"
  928. ---help---
  929. This option only applies to PCI-SCSI chips that are PCI DAC
  930. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  931. When set to 0, the driver will program the chip to only perform
  932. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  933. to addresses up to 1TB. When set to 2, the driver supports the
  934. full 64-bit DMA address range, but can only address 16 segments
  935. of 4 GB each. This limits the total addressable range to 64 GB.
  936. Most machines with less than 4GB of memory should use a setting
  937. of 0 for best performance. If your machine has 4GB of memory
  938. or more, you should set this option to 1 (the default).
  939. The still experimental value 2 (64 bit DMA addressing with 16
  940. x 4GB segments limitation) can be used on systems that require
  941. PCI address bits past bit 39 to be set for the addressing of
  942. memory using PCI DAC cycles.
  943. config SCSI_SYM53C8XX_DEFAULT_TAGS
  944. int "Default tagged command queue depth"
  945. depends on SCSI_SYM53C8XX_2
  946. default "16"
  947. help
  948. This is the default value of the command queue depth the
  949. driver will announce to the generic SCSI layer for devices
  950. that support tagged command queueing. This value can be changed
  951. from the boot command line. This is a soft limit that cannot
  952. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  953. config SCSI_SYM53C8XX_MAX_TAGS
  954. int "Maximum number of queued commands"
  955. depends on SCSI_SYM53C8XX_2
  956. default "64"
  957. help
  958. This option allows you to specify the maximum number of commands
  959. that can be queued to any device, when tagged command queuing is
  960. possible. The driver supports up to 256 queued commands per device.
  961. This value is used as a compiled-in hard limit.
  962. config SCSI_SYM53C8XX_MMIO
  963. bool "Use memory mapped IO"
  964. depends on SCSI_SYM53C8XX_2
  965. default y
  966. help
  967. Memory mapped IO is faster than Port IO. Most people should
  968. answer Y here, but some machines may have problems. If you have
  969. to answer N here, please report the problem to the maintainer.
  970. config SCSI_IPR
  971. tristate "IBM Power Linux RAID adapter support"
  972. depends on PCI && SCSI && ATA
  973. select FW_LOADER
  974. ---help---
  975. This driver supports the IBM Power Linux family RAID adapters.
  976. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  977. as IBM iSeries 5702, 5703, 5709, and 570A.
  978. config SCSI_IPR_TRACE
  979. bool "enable driver internal trace"
  980. depends on SCSI_IPR
  981. default y
  982. help
  983. If you say Y here, the driver will trace all commands issued
  984. to the adapter. Performance impact is minimal. Trace can be
  985. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  986. config SCSI_IPR_DUMP
  987. bool "enable adapter dump support"
  988. depends on SCSI_IPR
  989. default y
  990. help
  991. If you say Y here, the driver will support adapter crash dump.
  992. If you enable this support, the iprdump daemon can be used
  993. to capture adapter failure analysis information.
  994. config SCSI_ZALON
  995. tristate "Zalon SCSI support"
  996. depends on GSC && SCSI
  997. select SCSI_SPI_ATTRS
  998. help
  999. The Zalon is a GSC/HSC bus interface chip that sits between the
  1000. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  1001. C110, J200, J210 and some D, K & R-class machines. It's also
  1002. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  1003. Say Y here if you have one of these machines or cards.
  1004. config SCSI_NCR_Q720
  1005. tristate "NCR Quad 720 MCA SCSI support"
  1006. depends on MCA && SCSI
  1007. select SCSI_SPI_ATTRS
  1008. help
  1009. This is a driver for the MicroChannel Quad 720 card produced by
  1010. NCR and commonly used in 345x/35xx/4100 class machines. It always
  1011. tries to negotiate sync and uses tag command queueing.
  1012. Unless you have an NCR manufactured machine, the chances are that
  1013. you do not have this SCSI card, so say N.
  1014. config SCSI_NCR53C8XX_DEFAULT_TAGS
  1015. int "default tagged command queue depth"
  1016. depends on SCSI_ZALON || SCSI_NCR_Q720
  1017. default "8"
  1018. ---help---
  1019. "Tagged command queuing" is a feature of SCSI-2 which improves
  1020. performance: the host adapter can send several SCSI commands to a
  1021. device's queue even if previous commands haven't finished yet.
  1022. Because the device is intelligent, it can optimize its operations
  1023. (like head positioning) based on its own request queue. Some SCSI
  1024. devices don't implement this properly; if you want to disable this
  1025. feature, enter 0 or 1 here (it doesn't matter which).
  1026. The default value is 8 and should be supported by most hard disks.
  1027. This value can be overridden from the boot command line using the
  1028. 'tags' option as follows (example):
  1029. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  1030. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  1031. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  1032. The normal answer therefore is to go with the default 8 and to use
  1033. a boot command line option for devices that need to use a different
  1034. command queue depth.
  1035. There is no safe option other than using good SCSI devices.
  1036. config SCSI_NCR53C8XX_MAX_TAGS
  1037. int "maximum number of queued commands"
  1038. depends on SCSI_ZALON || SCSI_NCR_Q720
  1039. default "32"
  1040. ---help---
  1041. This option allows you to specify the maximum number of commands
  1042. that can be queued to any device, when tagged command queuing is
  1043. possible. The default value is 32. Minimum is 2, maximum is 64.
  1044. Modern hard disks are able to support 64 tags and even more, but
  1045. do not seem to be faster when more than 32 tags are being used.
  1046. So, the normal answer here is to go with the default value 32 unless
  1047. you are using very large hard disks with large cache (>= 1 MB) that
  1048. are able to take advantage of more than 32 tagged commands.
  1049. There is no safe option and the default answer is recommended.
  1050. config SCSI_NCR53C8XX_SYNC
  1051. int "synchronous transfers frequency in MHz"
  1052. depends on SCSI_ZALON || SCSI_NCR_Q720
  1053. default "20"
  1054. ---help---
  1055. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  1056. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  1057. are respectively the maximum data transfer rates in mega-transfers
  1058. per second for each class. For example, a FAST-20 Wide 16 device is
  1059. able to transfer data at 20 million 16 bit packets per second for a
  1060. total rate of 40 MB/s.
  1061. You may specify 0 if you want to only use asynchronous data
  1062. transfers. This is the safest and slowest option. Otherwise, specify
  1063. a value between 5 and 80, depending on the capability of your SCSI
  1064. controller. The higher the number, the faster the data transfer.
  1065. Note that 80 should normally be ok since the driver decreases the
  1066. value automatically according to the controller's capabilities.
  1067. Your answer to this question is ignored for controllers with NVRAM,
  1068. since the driver will get this information from the user set-up. It
  1069. also can be overridden using a boot setup option, as follows
  1070. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  1071. for FAST-20 synchronous data transfer (20 mega-transfers per
  1072. second).
  1073. The normal answer therefore is not to go with the default but to
  1074. select the maximum value 80 allowing the driver to use the maximum
  1075. value supported by each controller. If this causes problems with
  1076. your SCSI devices, you should come back and decrease the value.
  1077. There is no safe option other than using good cabling, right
  1078. terminations and SCSI conformant devices.
  1079. config SCSI_NCR53C8XX_NO_DISCONNECT
  1080. bool "not allow targets to disconnect"
  1081. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  1082. help
  1083. This option is only provided for safety if you suspect some SCSI
  1084. device of yours to not support properly the target-disconnect
  1085. feature. In that case, you would say Y here. In general however, to
  1086. not allow targets to disconnect is not reasonable if there is more
  1087. than 1 device on a SCSI bus. The normal answer therefore is N.
  1088. config SCSI_PAS16
  1089. tristate "PAS16 SCSI support"
  1090. depends on ISA && SCSI
  1091. select SCSI_SPI_ATTRS
  1092. ---help---
  1093. This is support for a SCSI host adapter. It is explained in section
  1094. 3.10 of the SCSI-HOWTO, available from
  1095. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1096. of the box, you may have to change some settings in
  1097. <file:drivers/scsi/pas16.h>.
  1098. To compile this driver as a module, choose M here: the
  1099. module will be called pas16.
  1100. config SCSI_QLOGIC_FAS
  1101. tristate "Qlogic FAS SCSI support"
  1102. depends on ISA && SCSI
  1103. ---help---
  1104. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1105. FastSCSI! cards as well as any other card based on the FASXX chip
  1106. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1107. This driver does NOT support the PCI versions of these cards. The
  1108. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1109. SCSI support"), below.
  1110. Information about this driver is contained in
  1111. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1112. SCSI-HOWTO, available from
  1113. <http://www.tldp.org/docs.html#howto>.
  1114. To compile this driver as a module, choose M here: the
  1115. module will be called qlogicfas.
  1116. config SCSI_QLOGIC_FC_FIRMWARE
  1117. bool "Include loadable firmware in driver"
  1118. depends on SCSI_QLOGIC_FC
  1119. help
  1120. Say Y to include ISP2X00 Fabric Initiator/Target Firmware, with
  1121. expanded LUN addressing and FcTape (FCP-2) support, in the
  1122. qlogicfc driver. This is required on some platforms.
  1123. config SCSI_QLOGIC_1280
  1124. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1125. depends on PCI && SCSI
  1126. help
  1127. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1128. To compile this driver as a module, choose M here: the
  1129. module will be called qla1280.
  1130. config SCSI_QLOGICPTI
  1131. tristate "PTI Qlogic, ISP Driver"
  1132. depends on SBUS && SCSI
  1133. help
  1134. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1135. controllers are known under Solaris as qpti and in the openprom as
  1136. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1137. driven by a different driver.
  1138. To compile this driver as a module, choose M here: the
  1139. module will be called qlogicpti.
  1140. source "drivers/scsi/qla2xxx/Kconfig"
  1141. source "drivers/scsi/qla4xxx/Kconfig"
  1142. config SCSI_LPFC
  1143. tristate "Emulex LightPulse Fibre Channel Support"
  1144. depends on PCI && SCSI
  1145. select SCSI_FC_ATTRS
  1146. help
  1147. This lpfc driver supports the Emulex LightPulse
  1148. Family of Fibre Channel PCI host adapters.
  1149. config SCSI_SIM710
  1150. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1151. depends on (EISA || MCA) && SCSI
  1152. select SCSI_SPI_ATTRS
  1153. ---help---
  1154. This driver for NCR53c710 based SCSI host adapters.
  1155. It currently supports Compaq EISA cards and NCR MCA cards
  1156. config SCSI_SYM53C416
  1157. tristate "Symbios 53c416 SCSI support"
  1158. depends on ISA && SCSI
  1159. ---help---
  1160. This is support for the sym53c416 SCSI host adapter, the SCSI
  1161. adapter that comes with some HP scanners. This driver requires that
  1162. the sym53c416 is configured first using some sort of PnP
  1163. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1164. are using isapnp then you need to compile this driver as a module
  1165. and then load it using insmod after isapnp has run. The parameters
  1166. of the configured card(s) should be passed to the driver. The format
  1167. is:
  1168. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1169. To compile this driver as a module, choose M here: the
  1170. module will be called sym53c416.
  1171. config SCSI_DC395x
  1172. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1173. depends on PCI && SCSI && EXPERIMENTAL
  1174. ---help---
  1175. This driver supports PCI SCSI host adapters based on the ASIC
  1176. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1177. This driver works, but is still in experimental status. So better
  1178. have a bootable disk and a backup in case of emergency.
  1179. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1180. To compile this driver as a module, choose M here: the
  1181. module will be called dc395x.
  1182. config SCSI_DC390T
  1183. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1184. depends on PCI && SCSI
  1185. ---help---
  1186. This driver supports PCI SCSI host adapters based on the Am53C974A
  1187. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1188. PCscsi/PCnet (Am53/79C974) solutions.
  1189. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1190. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1191. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1192. To compile this driver as a module, choose M here: the
  1193. module will be called tmscsim.
  1194. config SCSI_T128
  1195. tristate "Trantor T128/T128F/T228 SCSI support"
  1196. depends on ISA && SCSI
  1197. select SCSI_SPI_ATTRS
  1198. select CHECK_SIGNATURE
  1199. ---help---
  1200. This is support for a SCSI host adapter. It is explained in section
  1201. 3.11 of the SCSI-HOWTO, available from
  1202. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1203. of the box, you may have to change some settings in
  1204. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1205. Adaptec, and some former Trantor products are being sold under the
  1206. Adaptec name.
  1207. To compile this driver as a module, choose M here: the
  1208. module will be called t128.
  1209. config SCSI_U14_34F
  1210. tristate "UltraStor 14F/34F support"
  1211. depends on ISA && SCSI && ISA_DMA_API
  1212. ---help---
  1213. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1214. The source at <file:drivers/scsi/u14-34f.c> contains some
  1215. information about this hardware. If the driver doesn't work out of
  1216. the box, you may have to change some settings in
  1217. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1218. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1219. another driver for the same hardware: "UltraStor SCSI support",
  1220. below. You should say Y to both only if you want 24F support as
  1221. well.
  1222. To compile this driver as a module, choose M here: the
  1223. module will be called u14-34f.
  1224. config SCSI_U14_34F_TAGGED_QUEUE
  1225. bool "enable tagged command queueing"
  1226. depends on SCSI_U14_34F
  1227. help
  1228. This is a feature of SCSI-2 which improves performance: the host
  1229. adapter can send several SCSI commands to a device's queue even if
  1230. previous commands haven't finished yet.
  1231. This is equivalent to the "u14-34f=tc:y" boot option.
  1232. config SCSI_U14_34F_LINKED_COMMANDS
  1233. bool "enable elevator sorting"
  1234. depends on SCSI_U14_34F
  1235. help
  1236. This option enables elevator sorting for all probed SCSI disks and
  1237. CD-ROMs. It definitely reduces the average seek distance when doing
  1238. random seeks, but this does not necessarily result in a noticeable
  1239. performance improvement: your mileage may vary...
  1240. This is equivalent to the "u14-34f=lc:y" boot option.
  1241. config SCSI_U14_34F_MAX_TAGS
  1242. int "maximum number of queued commands"
  1243. depends on SCSI_U14_34F
  1244. default "8"
  1245. help
  1246. This specifies how many SCSI commands can be maximally queued for
  1247. each probed SCSI device. You should reduce the default value of 8
  1248. only if you have disks with buggy or limited tagged command support.
  1249. Minimum is 2 and maximum is 14. This value is also the window size
  1250. used by the elevator sorting option above. The effective value used
  1251. by the driver for each probed SCSI device is reported at boot time.
  1252. This is equivalent to the "u14-34f=mq:8" boot option.
  1253. config SCSI_ULTRASTOR
  1254. tristate "UltraStor SCSI support"
  1255. depends on X86 && ISA && SCSI
  1256. ---help---
  1257. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1258. adapter family. This driver is explained in section 3.12 of the
  1259. SCSI-HOWTO, available from
  1260. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1261. of the box, you may have to change some settings in
  1262. <file:drivers/scsi/ultrastor.h>.
  1263. Note that there is also another driver for the same hardware:
  1264. "UltraStor 14F/34F support", above.
  1265. To compile this driver as a module, choose M here: the
  1266. module will be called ultrastor.
  1267. config SCSI_NSP32
  1268. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1269. depends on PCI && SCSI && !64BIT
  1270. help
  1271. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1272. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1273. <http://www.tldp.org/docs.html#howto>.
  1274. To compile this driver as a module, choose M here: the
  1275. module will be called nsp32.
  1276. config SCSI_DEBUG
  1277. tristate "SCSI debugging host simulator"
  1278. depends on SCSI
  1279. help
  1280. This is a host adapter simulator that can simulate multiple hosts
  1281. each with multiple dummy SCSI devices (disks). It defaults to one
  1282. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1283. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1284. dummy disks are simulated, they share the same kernel RAM for
  1285. their storage. See <http://www.torque.net/sg/sdebug.html> for more
  1286. information. This driver is primarily of use to those testing the
  1287. SCSI and block subsystems. If unsure, say N.
  1288. config SCSI_MESH
  1289. tristate "MESH (Power Mac internal SCSI) support"
  1290. depends on PPC32 && PPC_PMAC && SCSI
  1291. help
  1292. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1293. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1294. other Power Macintoshes do). Say Y to include support for this SCSI
  1295. adaptor.
  1296. To compile this driver as a module, choose M here: the
  1297. module will be called mesh.
  1298. config SCSI_MESH_SYNC_RATE
  1299. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1300. depends on SCSI_MESH
  1301. default "5"
  1302. help
  1303. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1304. drives a bus which is entirely internal to the machine (such as the
  1305. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1306. operation at up to 10 MB/s. On machines where the SCSI bus
  1307. controlled by the MESH can have external devices connected, it is
  1308. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1309. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1310. to disable synchronous operation.
  1311. config SCSI_MESH_RESET_DELAY_MS
  1312. int "initial bus reset delay (ms) (0 = no reset)"
  1313. depends on SCSI_MESH
  1314. default "4000"
  1315. config SCSI_MAC53C94
  1316. tristate "53C94 (Power Mac external SCSI) support"
  1317. depends on PPC32 && PPC_PMAC && SCSI
  1318. help
  1319. On Power Macintoshes (and clones) with two SCSI buses, the external
  1320. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1321. machines which only have one SCSI bus, such as the 7200, also use
  1322. the 53C94. Say Y to include support for the 53C94.
  1323. To compile this driver as a module, choose M here: the
  1324. module will be called mac53c94.
  1325. source "drivers/scsi/arm/Kconfig"
  1326. config JAZZ_ESP
  1327. bool "MIPS JAZZ FAS216 SCSI support"
  1328. depends on MACH_JAZZ && SCSI
  1329. select SCSI_SPI_ATTRS
  1330. help
  1331. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1332. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1333. systems.
  1334. config A3000_SCSI
  1335. tristate "A3000 WD33C93A support"
  1336. depends on AMIGA && SCSI
  1337. help
  1338. If you have an Amiga 3000 and have SCSI devices connected to the
  1339. built-in SCSI controller, say Y. Otherwise, say N.
  1340. To compile this driver as a module, choose M here: the
  1341. module will be called a3000.
  1342. config A2091_SCSI
  1343. tristate "A2091/A590 WD33C93A support"
  1344. depends on ZORRO && SCSI
  1345. help
  1346. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1347. say N.
  1348. To compile this driver as a module, choose M here: the
  1349. module will be called a2091.
  1350. config GVP11_SCSI
  1351. tristate "GVP Series II WD33C93A support"
  1352. depends on ZORRO && SCSI
  1353. ---help---
  1354. If you have a Great Valley Products Series II SCSI controller,
  1355. answer Y. Also say Y if you have a later model of GVP SCSI
  1356. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1357. answer N. This driver does NOT work for the T-Rex series of
  1358. accelerators from TekMagic and GVP-M.
  1359. To compile this driver as a module, choose M here: the
  1360. module will be called gvp11.
  1361. config SCSI_A4000T
  1362. tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
  1363. depends on AMIGA && SCSI && EXPERIMENTAL
  1364. select SCSI_SPI_ATTRS
  1365. help
  1366. If you have an Amiga 4000T and have SCSI devices connected to the
  1367. built-in SCSI controller, say Y. Otherwise, say N.
  1368. To compile this driver as a module, choose M here: the
  1369. module will be called a4000t.
  1370. config SCSI_ZORRO7XX
  1371. tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
  1372. depends on ZORRO && SCSI && EXPERIMENTAL
  1373. select SCSI_SPI_ATTRS
  1374. help
  1375. Support for various NCR53c710-based SCSI controllers on Zorro
  1376. expansion boards for the Amiga.
  1377. This includes:
  1378. - the Amiga 4091 Zorro III SCSI-2 controller,
  1379. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1380. (info at
  1381. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1382. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1383. accelerator card for the Amiga 1200,
  1384. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1385. config ATARI_SCSI
  1386. tristate "Atari native SCSI support"
  1387. depends on ATARI && SCSI
  1388. select SCSI_SPI_ATTRS
  1389. ---help---
  1390. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1391. Falcon, ...) say Y to get it supported. Of course also, if you have
  1392. a compatible SCSI controller (e.g. for Medusa).
  1393. To compile this driver as a module, choose M here: the
  1394. module will be called atari_scsi.
  1395. This driver supports both styles of NCR integration into the
  1396. system: the TT style (separate DMA), and the Falcon style (via
  1397. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1398. in the Hades (without DMA).
  1399. config ATARI_SCSI_TOSHIBA_DELAY
  1400. bool "Long delays for Toshiba CD-ROMs"
  1401. depends on ATARI_SCSI
  1402. help
  1403. This option increases the delay after a SCSI arbitration to
  1404. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1405. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1406. would impact performance a bit, so say N.
  1407. config ATARI_SCSI_RESET_BOOT
  1408. bool "Reset SCSI-devices at boottime"
  1409. depends on ATARI_SCSI
  1410. help
  1411. Reset the devices on your Atari whenever it boots. This makes the
  1412. boot process fractionally longer but may assist recovery from errors
  1413. that leave the devices with SCSI operations partway completed.
  1414. config TT_DMA_EMUL
  1415. bool "Hades SCSI DMA emulator"
  1416. depends on ATARI_SCSI && HADES
  1417. help
  1418. This option enables code which emulates the TT SCSI DMA chip on the
  1419. Hades. This increases the SCSI transfer rates at least ten times
  1420. compared to PIO transfers.
  1421. config MAC_SCSI
  1422. bool "Macintosh NCR5380 SCSI"
  1423. depends on MAC && SCSI=y
  1424. select SCSI_SPI_ATTRS
  1425. help
  1426. This is the NCR 5380 SCSI controller included on most of the 68030
  1427. based Macintoshes. If you have one of these say Y and read the
  1428. SCSI-HOWTO, available from
  1429. <http://www.tldp.org/docs.html#howto>.
  1430. config SCSI_MAC_ESP
  1431. tristate "Macintosh NCR53c9[46] SCSI"
  1432. depends on MAC && SCSI
  1433. select SCSI_SPI_ATTRS
  1434. help
  1435. This is the NCR 53c9x SCSI controller found on most of the 68040
  1436. based Macintoshes.
  1437. To compile this driver as a module, choose M here: the module
  1438. will be called mac_esp.
  1439. config MVME147_SCSI
  1440. bool "WD33C93 SCSI driver for MVME147"
  1441. depends on MVME147 && SCSI=y
  1442. select SCSI_SPI_ATTRS
  1443. help
  1444. Support for the on-board SCSI controller on the Motorola MVME147
  1445. single-board computer.
  1446. config MVME16x_SCSI
  1447. tristate "NCR53C710 SCSI driver for MVME16x"
  1448. depends on MVME16x && SCSI
  1449. select SCSI_SPI_ATTRS
  1450. help
  1451. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1452. SCSI controller chip. Almost everyone using one of these boards
  1453. will want to say Y to this question.
  1454. config BVME6000_SCSI
  1455. tristate "NCR53C710 SCSI driver for BVME6000"
  1456. depends on BVME6000 && SCSI
  1457. select SCSI_SPI_ATTRS
  1458. help
  1459. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1460. SCSI controller chip. Almost everyone using one of these boards
  1461. will want to say Y to this question.
  1462. config SUN3_SCSI
  1463. tristate "Sun3 NCR5380 SCSI"
  1464. depends on SUN3 && SCSI
  1465. select SCSI_SPI_ATTRS
  1466. help
  1467. This option will enable support for the OBIO (onboard io) NCR5380
  1468. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1469. "Sun3" type VME scsi controllers also based on the NCR5380.
  1470. General Linux information on the Sun 3 series (now discontinued)
  1471. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1472. config SUN3X_ESP
  1473. bool "Sun3x ESP SCSI"
  1474. depends on SUN3X && SCSI=y
  1475. select SCSI_SPI_ATTRS
  1476. help
  1477. The ESP was an on-board SCSI controller used on Sun 3/80
  1478. machines. Say Y here to compile in support for it.
  1479. config SCSI_SUNESP
  1480. tristate "Sparc ESP Scsi Driver"
  1481. depends on SBUS && SCSI
  1482. select SCSI_SPI_ATTRS
  1483. help
  1484. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1485. chipset is present in most SPARC SBUS-based computers and
  1486. supports the Emulex family of ESP SCSI chips (esp100, esp100A,
  1487. esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
  1488. To compile this driver as a module, choose M here: the
  1489. module will be called sun_esp.
  1490. config ZFCP
  1491. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1492. depends on S390 && QDIO && SCSI
  1493. select SCSI_FC_ATTRS
  1494. help
  1495. If you want to access SCSI devices attached to your IBM eServer
  1496. zSeries by means of Fibre Channel interfaces say Y.
  1497. For details please refer to the documentation provided by IBM at
  1498. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1499. This driver is also available as a module. This module will be
  1500. called zfcp. If you want to compile it as a module, say M here
  1501. and read <file:Documentation/kbuild/modules.txt>.
  1502. config SCSI_SRP
  1503. tristate "SCSI RDMA Protocol helper library"
  1504. depends on SCSI && PCI
  1505. select SCSI_TGT
  1506. help
  1507. If you wish to use SRP target drivers, say Y.
  1508. To compile this driver as a module, choose M here: the
  1509. module will be called libsrp.
  1510. endif # SCSI_LOWLEVEL
  1511. source "drivers/scsi/pcmcia/Kconfig"
  1512. source "drivers/scsi/device_handler/Kconfig"
  1513. endmenu