12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802180318041805180618071808180918101811181218131814181518161817181818191820182118221823182418251826182718281829183018311832183318341835183618371838183918401841184218431844184518461847184818491850185118521853185418551856185718581859186018611862186318641865186618671868186918701871187218731874187518761877187818791880188118821883188418851886
  1. menu "SCSI device support"
  2. config RAID_ATTRS
  3. tristate "RAID Transport Class"
  4. default n
  5. depends on BLOCK
  6. ---help---
  7. Provides RAID
  8. config SCSI
  9. tristate "SCSI device support"
  10. depends on BLOCK
  11. select SCSI_DMA if HAS_DMA
  12. ---help---
  13. If you want to use a SCSI hard disk, SCSI tape drive, SCSI CD-ROM or
  14. any other SCSI device under Linux, say Y and make sure that you know
  15. the name of your SCSI host adapter (the card inside your computer
  16. that "speaks" the SCSI protocol, also called SCSI controller),
  17. because you will be asked for it.
  18. You also need to say Y here if you have a device which speaks
  19. the SCSI protocol. Examples of this include the parallel port
  20. version of the IOMEGA ZIP drive, USB storage devices, Fibre
  21. Channel, and FireWire storage.
  22. To compile this driver as a module, choose M here and read
  23. <file:Documentation/scsi/scsi.txt>.
  24. The module will be called scsi_mod.
  25. However, do not compile this as a module if your root file system
  26. (the one containing the directory /) is located on a SCSI device.
  27. config SCSI_DMA
  28. bool
  29. default n
  30. config SCSI_TGT
  31. tristate "SCSI target support"
  32. depends on SCSI && EXPERIMENTAL
  33. ---help---
  34. If you want to use SCSI target mode drivers enable this option.
  35. If you choose M, the module will be called scsi_tgt.
  36. config SCSI_NETLINK
  37. bool
  38. default n
  39. select NET
  40. config SCSI_PROC_FS
  41. bool "legacy /proc/scsi/ support"
  42. depends on SCSI && PROC_FS
  43. default y
  44. ---help---
  45. This option enables support for the various files in
  46. /proc/scsi. In Linux 2.6 this has been superseded by
  47. files in sysfs but many legacy applications rely on this.
  48. If unsure say Y.
  49. comment "SCSI support type (disk, tape, CD-ROM)"
  50. depends on SCSI
  51. config BLK_DEV_SD
  52. tristate "SCSI disk support"
  53. depends on SCSI
  54. select CRC_T10DIF if BLK_DEV_INTEGRITY
  55. ---help---
  56. If you want to use SCSI hard disks, Fibre Channel disks,
  57. Serial ATA (SATA) or Parallel ATA (PATA) hard disks,
  58. USB storage or the SCSI or parallel port version of
  59. the IOMEGA ZIP drive, say Y and read the SCSI-HOWTO,
  60. the Disk-HOWTO and the Multi-Disk-HOWTO, available from
  61. <http://www.tldp.org/docs.html#howto>. This is NOT for SCSI
  62. CD-ROMs.
  63. To compile this driver as a module, choose M here and read
  64. <file:Documentation/scsi/scsi.txt>.
  65. The module will be called sd_mod.
  66. Do not compile this driver as a module if your root file system
  67. (the one containing the directory /) is located on a SCSI disk.
  68. In this case, do not compile the driver for your SCSI host adapter
  69. (below) as a module either.
  70. config CHR_DEV_ST
  71. tristate "SCSI tape support"
  72. depends on SCSI
  73. ---help---
  74. If you want to use a SCSI tape drive under Linux, say Y and read the
  75. SCSI-HOWTO, available from
  76. <http://www.tldp.org/docs.html#howto>, and
  77. <file:Documentation/scsi/st.txt> in the kernel source. This is NOT
  78. for SCSI CD-ROMs.
  79. To compile this driver as a module, choose M here and read
  80. <file:Documentation/scsi/scsi.txt>. The module will be called st.
  81. config CHR_DEV_OSST
  82. tristate "SCSI OnStream SC-x0 tape support"
  83. depends on SCSI
  84. ---help---
  85. The OnStream SC-x0 SCSI tape drives cannot be driven by the
  86. standard st driver, but instead need this special osst driver and
  87. use the /dev/osstX char device nodes (major 206). Via usb-storage,
  88. you may be able to drive the USB-x0 and DI-x0 drives as well.
  89. Note that there is also a second generation of OnStream
  90. tape drives (ADR-x0) that supports the standard SCSI-2 commands for
  91. tapes (QIC-157) and can be driven by the standard driver st.
  92. For more information, you may have a look at the SCSI-HOWTO
  93. <http://www.tldp.org/docs.html#howto> and
  94. <file:Documentation/scsi/osst.txt> in the kernel source.
  95. More info on the OnStream driver may be found on
  96. <http://linux1.onstream.nl/test/>
  97. Please also have a look at the standard st docu, as most of it
  98. applies to osst as well.
  99. To compile this driver as a module, choose M here and read
  100. <file:Documentation/scsi/scsi.txt>. The module will be called osst.
  101. config BLK_DEV_SR
  102. tristate "SCSI CDROM support"
  103. depends on SCSI
  104. ---help---
  105. If you want to use a CD or DVD drive attached to your computer
  106. by SCSI, FireWire, USB or ATAPI, say Y and read the SCSI-HOWTO
  107. and the CDROM-HOWTO at <http://www.tldp.org/docs.html#howto>.
  108. Make sure to say Y or M to "ISO 9660 CD-ROM file system support".
  109. To compile this driver as a module, choose M here and read
  110. <file:Documentation/scsi/scsi.txt>.
  111. The module will be called sr_mod.
  112. config BLK_DEV_SR_VENDOR
  113. bool "Enable vendor-specific extensions (for SCSI CDROM)"
  114. depends on BLK_DEV_SR
  115. help
  116. This enables the usage of vendor specific SCSI commands. This is
  117. required to support multisession CDs with old NEC/TOSHIBA cdrom
  118. drives (and HP Writers). If you have such a drive and get the first
  119. session only, try saying Y here; everybody else says N.
  120. config CHR_DEV_SG
  121. tristate "SCSI generic support"
  122. depends on SCSI
  123. ---help---
  124. If you want to use SCSI scanners, synthesizers or CD-writers or just
  125. about anything having "SCSI" in its name other than hard disks,
  126. CD-ROMs or tapes, say Y here. These won't be supported by the kernel
  127. directly, so you need some additional software which knows how to
  128. talk to these devices using the SCSI protocol:
  129. For scanners, look at SANE (<http://www.mostang.com/sane/>). For CD
  130. writer software look at Cdrtools
  131. (<http://www.fokus.gmd.de/research/cc/glone/employees/joerg.schilling/private/cdrecord.html>)
  132. and for burning a "disk at once": CDRDAO
  133. (<http://cdrdao.sourceforge.net/>). Cdparanoia is a high
  134. quality digital reader of audio CDs (<http://www.xiph.org/paranoia/>).
  135. For other devices, it's possible that you'll have to write the
  136. driver software yourself. Please read the file
  137. <file:Documentation/scsi/scsi-generic.txt> for more information.
  138. To compile this driver as a module, choose M here and read
  139. <file:Documentation/scsi/scsi.txt>. The module will be called sg.
  140. If unsure, say N.
  141. config CHR_DEV_SCH
  142. tristate "SCSI media changer support"
  143. depends on SCSI
  144. ---help---
  145. This is a driver for SCSI media changers. Most common devices are
  146. tape libraries and MOD/CDROM jukeboxes. *Real* jukeboxes, you
  147. don't need this for those tiny 6-slot cdrom changers. Media
  148. changers are listed as "Type: Medium Changer" in /proc/scsi/scsi.
  149. If you have such hardware and want to use it with linux, say Y
  150. here. Check <file:Documentation/scsi/scsi-changer.txt> for details.
  151. If you want to compile this as a module ( = code which can be
  152. inserted in and removed from the running kernel whenever you want),
  153. say M here and read <file:Documentation/kbuild/modules.txt> and
  154. <file:Documentation/scsi/scsi.txt>. The module will be called ch.o.
  155. If unsure, say N.
  156. config SCSI_ENCLOSURE
  157. tristate "SCSI Enclosure Support"
  158. depends on SCSI && ENCLOSURE_SERVICES
  159. help
  160. Enclosures are devices sitting on or in SCSI backplanes that
  161. manage devices. If you have a disk cage, the chances are that
  162. it has an enclosure device. Selecting this option will just allow
  163. certain enclosure conditions to be reported and is not required.
  164. config SCSI_MULTI_LUN
  165. bool "Probe all LUNs on each SCSI device"
  166. depends on SCSI
  167. help
  168. Some devices support more than one LUN (Logical Unit Number) in order
  169. to allow access to several media, e.g. CD jukebox, USB card reader,
  170. mobile phone in mass storage mode. This option forces the kernel to
  171. probe for all LUNs by default. This setting can be overriden by
  172. max_luns boot/module parameter. Note that this option does not affect
  173. devices conforming to SCSI-3 or higher as they can explicitely report
  174. their number of LUNs. It is safe to say Y here unless you have one of
  175. those rare devices which reacts in an unexpected way when probed for
  176. multiple LUNs.
  177. config SCSI_CONSTANTS
  178. bool "Verbose SCSI error reporting (kernel size +=12K)"
  179. depends on SCSI
  180. help
  181. The error messages regarding your SCSI hardware will be easier to
  182. understand if you say Y here; it will enlarge your kernel by about
  183. 12 KB. If in doubt, say Y.
  184. config SCSI_LOGGING
  185. bool "SCSI logging facility"
  186. depends on SCSI
  187. ---help---
  188. This turns on a logging facility that can be used to debug a number
  189. of SCSI related problems.
  190. If you say Y here, no logging output will appear by default, but you
  191. can enable logging by saying Y to "/proc file system support" and
  192. "Sysctl support" below and executing the command
  193. echo <bitmask> > /proc/sys/dev/scsi/logging_level
  194. where <bitmask> is a four byte value representing the logging type
  195. and logging level for each type of logging selected.
  196. There are a number of logging types and you can find them in the
  197. source at <file:drivers/scsi/scsi_logging.h>. The logging levels
  198. are also described in that file and they determine the verbosity of
  199. the logging for each logging type.
  200. If you say N here, it may be harder to track down some types of SCSI
  201. problems. If you say Y here your kernel will be somewhat larger, but
  202. there should be no noticeable performance impact as long as you have
  203. logging turned off.
  204. config SCSI_SCAN_ASYNC
  205. bool "Asynchronous SCSI scanning"
  206. depends on SCSI
  207. help
  208. The SCSI subsystem can probe for devices while the rest of the
  209. system continues booting, and even probe devices on different
  210. busses in parallel, leading to a significant speed-up.
  211. If you have built SCSI as modules, enabling this option can
  212. be a problem as the devices may not have been found by the
  213. time your system expects them to have been. You can load the
  214. scsi_wait_scan module to ensure that all scans have completed.
  215. If you build your SCSI drivers into the kernel, then everything
  216. will work fine if you say Y here.
  217. You can override this choice by specifying "scsi_mod.scan=sync"
  218. or async on the kernel's command line.
  219. config SCSI_WAIT_SCAN
  220. tristate # No prompt here, this is an invisible symbol.
  221. default m
  222. depends on SCSI
  223. depends on MODULES
  224. # scsi_wait_scan is a loadable module which waits until all the async scans are
  225. # complete. The idea is to use it in initrd/ initramfs scripts. You modprobe
  226. # it after all the modprobes of the root SCSI drivers and it will wait until
  227. # they have all finished scanning their buses before allowing the boot to
  228. # proceed. (This method is not applicable if targets boot independently in
  229. # parallel with the initiator, or with transports with non-deterministic target
  230. # discovery schemes, or if a transport driver does not support scsi_wait_scan.)
  231. #
  232. # This symbol is not exposed as a prompt because little is to be gained by
  233. # disabling it, whereas people who accidentally switch it off may wonder why
  234. # their mkinitrd gets into trouble.
  235. menu "SCSI Transports"
  236. depends on SCSI
  237. config SCSI_SPI_ATTRS
  238. tristate "Parallel SCSI (SPI) Transport Attributes"
  239. depends on SCSI
  240. help
  241. If you wish to export transport-specific information about
  242. each attached SCSI device to sysfs, say Y. Otherwise, say N.
  243. config SCSI_FC_ATTRS
  244. tristate "FiberChannel Transport Attributes"
  245. depends on SCSI
  246. select SCSI_NETLINK
  247. help
  248. If you wish to export transport-specific information about
  249. each attached FiberChannel device to sysfs, say Y.
  250. Otherwise, say N.
  251. config SCSI_FC_TGT_ATTRS
  252. bool "SCSI target support for FiberChannel Transport Attributes"
  253. depends on SCSI_FC_ATTRS
  254. depends on SCSI_TGT = y || SCSI_TGT = SCSI_FC_ATTRS
  255. help
  256. If you want to use SCSI target mode drivers enable this option.
  257. config SCSI_ISCSI_ATTRS
  258. tristate "iSCSI Transport Attributes"
  259. depends on SCSI && NET
  260. help
  261. If you wish to export transport-specific information about
  262. each attached iSCSI device to sysfs, say Y.
  263. Otherwise, say N.
  264. config SCSI_SAS_ATTRS
  265. tristate "SAS Transport Attributes"
  266. depends on SCSI && BLK_DEV_BSG
  267. help
  268. If you wish to export transport-specific information about
  269. each attached SAS device to sysfs, say Y.
  270. source "drivers/scsi/libsas/Kconfig"
  271. config SCSI_SRP_ATTRS
  272. tristate "SRP Transport Attributes"
  273. depends on SCSI
  274. help
  275. If you wish to export transport-specific information about
  276. each attached SRP device to sysfs, say Y.
  277. config SCSI_SRP_TGT_ATTRS
  278. bool "SCSI target support for SRP Transport Attributes"
  279. depends on SCSI_SRP_ATTRS
  280. depends on SCSI_TGT = y || SCSI_TGT = SCSI_SRP_ATTRS
  281. help
  282. If you want to use SCSI target mode drivers enable this option.
  283. endmenu
  284. menuconfig SCSI_LOWLEVEL
  285. bool "SCSI low-level drivers"
  286. depends on SCSI!=n
  287. default y
  288. if SCSI_LOWLEVEL && SCSI
  289. config ISCSI_TCP
  290. tristate "iSCSI Initiator over TCP/IP"
  291. depends on SCSI && INET
  292. select CRYPTO
  293. select CRYPTO_MD5
  294. select CRYPTO_CRC32C
  295. select SCSI_ISCSI_ATTRS
  296. help
  297. The iSCSI Driver provides a host with the ability to access storage
  298. through an IP network. The driver uses the iSCSI protocol to transport
  299. SCSI requests and responses over a TCP/IP network between the host
  300. (the "initiator") and "targets". Architecturally, the iSCSI driver
  301. combines with the host's TCP/IP stack, network drivers, and Network
  302. Interface Card (NIC) to provide the same functions as a SCSI or a
  303. Fibre Channel (FC) adapter driver with a Host Bus Adapter (HBA).
  304. To compile this driver as a module, choose M here: the
  305. module will be called iscsi_tcp.
  306. The userspace component needed to initialize the driver, documentation,
  307. and sample configuration files can be found here:
  308. http://open-iscsi.org
  309. source "drivers/scsi/cxgb3i/Kconfig"
  310. source "drivers/scsi/bnx2i/Kconfig"
  311. source "drivers/scsi/be2iscsi/Kconfig"
  312. config SGIWD93_SCSI
  313. tristate "SGI WD93C93 SCSI Driver"
  314. depends on SGI_HAS_WD93 && SCSI
  315. help
  316. If you have a Western Digital WD93 SCSI controller on
  317. an SGI MIPS system, say Y. Otherwise, say N.
  318. config BLK_DEV_3W_XXXX_RAID
  319. tristate "3ware 5/6/7/8xxx ATA-RAID support"
  320. depends on PCI && SCSI
  321. help
  322. 3ware is the only hardware ATA-Raid product in Linux to date.
  323. This card is 2,4, or 8 channel master mode support only.
  324. SCSI support required!!!
  325. <http://www.3ware.com/>
  326. Please read the comments at the top of
  327. <file:drivers/scsi/3w-xxxx.c>.
  328. config SCSI_HPSA
  329. tristate "HP Smart Array SCSI driver"
  330. depends on PCI && SCSI
  331. help
  332. This driver supports HP Smart Array Controllers (circa 2009).
  333. It is a SCSI alternative to the cciss driver, which is a block
  334. driver. Anyone wishing to use HP Smart Array controllers who
  335. would prefer the devices be presented to linux as SCSI devices,
  336. rather than as generic block devices should say Y here.
  337. config SCSI_3W_9XXX
  338. tristate "3ware 9xxx SATA-RAID support"
  339. depends on PCI && SCSI
  340. help
  341. This driver supports the 9000 series 3ware SATA-RAID cards.
  342. <http://www.amcc.com>
  343. Please read the comments at the top of
  344. <file:drivers/scsi/3w-9xxx.c>.
  345. config SCSI_3W_SAS
  346. tristate "3ware 97xx SAS/SATA-RAID support"
  347. depends on PCI && SCSI
  348. help
  349. This driver supports the LSI 3ware 9750 6Gb/s SAS/SATA-RAID cards.
  350. <http://www.lsi.com>
  351. Please read the comments at the top of
  352. <file:drivers/scsi/3w-sas.c>.
  353. config SCSI_7000FASST
  354. tristate "7000FASST SCSI support"
  355. depends on ISA && SCSI && ISA_DMA_API
  356. select CHECK_SIGNATURE
  357. help
  358. This driver supports the Western Digital 7000 SCSI host adapter
  359. family. Some information is in the source:
  360. <file:drivers/scsi/wd7000.c>.
  361. To compile this driver as a module, choose M here: the
  362. module will be called wd7000.
  363. config SCSI_ACARD
  364. tristate "ACARD SCSI support"
  365. depends on PCI && SCSI
  366. help
  367. This driver supports the ACARD SCSI host adapter.
  368. Support Chip <ATP870 ATP876 ATP880 ATP885>
  369. To compile this driver as a module, choose M here: the
  370. module will be called atp870u.
  371. config SCSI_AHA152X
  372. tristate "Adaptec AHA152X/2825 support"
  373. depends on ISA && SCSI && !64BIT
  374. select SCSI_SPI_ATTRS
  375. select CHECK_SIGNATURE
  376. ---help---
  377. This is a driver for the AHA-1510, AHA-1520, AHA-1522, and AHA-2825
  378. SCSI host adapters. It also works for the AVA-1505, but the IRQ etc.
  379. must be manually specified in this case.
  380. It is explained in section 3.3 of the SCSI-HOWTO, available from
  381. <http://www.tldp.org/docs.html#howto>. You might also want to
  382. read the file <file:Documentation/scsi/aha152x.txt>.
  383. To compile this driver as a module, choose M here: the
  384. module will be called aha152x.
  385. config SCSI_AHA1542
  386. tristate "Adaptec AHA1542 support"
  387. depends on ISA && SCSI && ISA_DMA_API
  388. ---help---
  389. This is support for a SCSI host adapter. It is explained in section
  390. 3.4 of the SCSI-HOWTO, available from
  391. <http://www.tldp.org/docs.html#howto>. Note that Trantor was
  392. purchased by Adaptec, and some former Trantor products are being
  393. sold under the Adaptec name. If it doesn't work out of the box, you
  394. may have to change some settings in <file:drivers/scsi/aha1542.h>.
  395. To compile this driver as a module, choose M here: the
  396. module will be called aha1542.
  397. config SCSI_AHA1740
  398. tristate "Adaptec AHA1740 support"
  399. depends on EISA && SCSI
  400. ---help---
  401. This is support for a SCSI host adapter. It is explained in section
  402. 3.5 of the SCSI-HOWTO, available from
  403. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  404. of the box, you may have to change some settings in
  405. <file:drivers/scsi/aha1740.h>.
  406. To compile this driver as a module, choose M here: the
  407. module will be called aha1740.
  408. config SCSI_AACRAID
  409. tristate "Adaptec AACRAID support"
  410. depends on SCSI && PCI
  411. help
  412. This driver supports a variety of Dell, HP, Adaptec, IBM and
  413. ICP storage products. For a list of supported products, refer
  414. to <file:Documentation/scsi/aacraid.txt>.
  415. To compile this driver as a module, choose M here: the module
  416. will be called aacraid.
  417. source "drivers/scsi/aic7xxx/Kconfig.aic7xxx"
  418. config SCSI_AIC7XXX_OLD
  419. tristate "Adaptec AIC7xxx support (old driver)"
  420. depends on (ISA || EISA || PCI ) && SCSI
  421. help
  422. WARNING This driver is an older aic7xxx driver and is no longer
  423. under active development. Adaptec, Inc. is writing a new driver to
  424. take the place of this one, and it is recommended that whenever
  425. possible, people should use the new Adaptec written driver instead
  426. of this one. This driver will eventually be phased out entirely.
  427. This is support for the various aic7xxx based Adaptec SCSI
  428. controllers. These include the 274x EISA cards; 284x VLB cards;
  429. 2902, 2910, 293x, 294x, 394x, 3985 and several other PCI and
  430. motherboard based SCSI controllers from Adaptec. It does not support
  431. the AAA-13x RAID controllers from Adaptec, nor will it likely ever
  432. support them. It does not support the 2920 cards from Adaptec that
  433. use the Future Domain SCSI controller chip. For those cards, you
  434. need the "Future Domain 16xx SCSI support" driver.
  435. In general, if the controller is based on an Adaptec SCSI controller
  436. chip from the aic777x series or the aic78xx series, this driver
  437. should work. The only exception is the 7810 which is specifically
  438. not supported (that's the RAID controller chip on the AAA-13x
  439. cards).
  440. Note that the AHA2920 SCSI host adapter is *not* supported by this
  441. driver; choose "Future Domain 16xx SCSI support" instead if you have
  442. one of those.
  443. Information on the configuration options for this controller can be
  444. found by checking the help file for each of the available
  445. configuration options. You should read
  446. <file:Documentation/scsi/aic7xxx_old.txt> at a minimum before
  447. contacting the maintainer with any questions. The SCSI-HOWTO,
  448. available from <http://www.tldp.org/docs.html#howto>, can also
  449. be of great help.
  450. To compile this driver as a module, choose M here: the
  451. module will be called aic7xxx_old.
  452. source "drivers/scsi/aic7xxx/Kconfig.aic79xx"
  453. source "drivers/scsi/aic94xx/Kconfig"
  454. source "drivers/scsi/mvsas/Kconfig"
  455. config SCSI_DPT_I2O
  456. tristate "Adaptec I2O RAID support "
  457. depends on SCSI && PCI && VIRT_TO_BUS
  458. help
  459. This driver supports all of Adaptec's I2O based RAID controllers as
  460. well as the DPT SmartRaid V cards. This is an Adaptec maintained
  461. driver by Deanna Bonds. See <file:Documentation/scsi/dpti.txt>.
  462. To compile this driver as a module, choose M here: the
  463. module will be called dpt_i2o.
  464. config SCSI_ADVANSYS
  465. tristate "AdvanSys SCSI support"
  466. depends on SCSI && VIRT_TO_BUS
  467. depends on ISA || EISA || PCI
  468. help
  469. This is a driver for all SCSI host adapters manufactured by
  470. AdvanSys. It is documented in the kernel source in
  471. <file:drivers/scsi/advansys.c>.
  472. To compile this driver as a module, choose M here: the
  473. module will be called advansys.
  474. config SCSI_IN2000
  475. tristate "Always IN2000 SCSI support"
  476. depends on ISA && SCSI
  477. help
  478. This is support for an ISA bus SCSI host adapter. You'll find more
  479. information in <file:Documentation/scsi/in2000.txt>. If it doesn't work
  480. out of the box, you may have to change the jumpers for IRQ or
  481. address selection.
  482. To compile this driver as a module, choose M here: the
  483. module will be called in2000.
  484. config SCSI_ARCMSR
  485. tristate "ARECA (ARC11xx/12xx/13xx/16xx) SATA/SAS RAID Host Adapter"
  486. depends on PCI && SCSI
  487. help
  488. This driver supports all of ARECA's SATA/SAS RAID controller cards.
  489. This is an ARECA-maintained driver by Erich Chen.
  490. If you have any problems, please mail to: <erich@areca.com.tw>.
  491. Areca supports Linux RAID config tools.
  492. Please link <http://www.areca.com.tw>
  493. To compile this driver as a module, choose M here: the
  494. module will be called arcmsr (modprobe arcmsr).
  495. config SCSI_ARCMSR_AER
  496. bool "Enable PCI Error Recovery Capability in Areca Driver(ARCMSR)"
  497. depends on SCSI_ARCMSR && PCIEAER
  498. default n
  499. help
  500. The advanced error reporting(AER) capability is "NOT" provided by
  501. ARC1200/1201/1202 SATA RAID controllers cards.
  502. If your card is one of ARC1200/1201/1202, please use the default setting, n.
  503. If your card is other models, you could pick it
  504. on condition that the kernel version is greater than 2.6.19.
  505. This function is maintained driver by Nick Cheng. If you have any
  506. problems or suggestion, you are welcome to contact with <nick.cheng@areca.com.tw>.
  507. To enable this function, choose Y here.
  508. source "drivers/scsi/megaraid/Kconfig.megaraid"
  509. source "drivers/scsi/mpt2sas/Kconfig"
  510. config SCSI_HPTIOP
  511. tristate "HighPoint RocketRAID 3xxx/4xxx Controller support"
  512. depends on SCSI && PCI
  513. help
  514. This option enables support for HighPoint RocketRAID 3xxx/4xxx
  515. controllers.
  516. To compile this driver as a module, choose M here; the module
  517. will be called hptiop. If unsure, say N.
  518. config SCSI_BUSLOGIC
  519. tristate "BusLogic SCSI support"
  520. depends on (PCI || ISA || MCA) && SCSI && ISA_DMA_API && VIRT_TO_BUS
  521. ---help---
  522. This is support for BusLogic MultiMaster and FlashPoint SCSI Host
  523. Adapters. Consult the SCSI-HOWTO, available from
  524. <http://www.tldp.org/docs.html#howto>, and the files
  525. <file:Documentation/scsi/BusLogic.txt> and
  526. <file:Documentation/scsi/FlashPoint.txt> for more information.
  527. Note that support for FlashPoint is only available for 32-bit
  528. x86 configurations.
  529. To compile this driver as a module, choose M here: the
  530. module will be called BusLogic.
  531. config SCSI_FLASHPOINT
  532. bool "FlashPoint support"
  533. depends on SCSI_BUSLOGIC && PCI && X86_32
  534. help
  535. This option allows you to add FlashPoint support to the
  536. BusLogic SCSI driver. The FlashPoint SCCB Manager code is
  537. substantial, so users of MultiMaster Host Adapters may not
  538. wish to include it.
  539. config VMWARE_PVSCSI
  540. tristate "VMware PVSCSI driver support"
  541. depends on PCI && SCSI && X86
  542. help
  543. This driver supports VMware's para virtualized SCSI HBA.
  544. To compile this driver as a module, choose M here: the
  545. module will be called vmw_pvscsi.
  546. config LIBFC
  547. tristate "LibFC module"
  548. select SCSI_FC_ATTRS
  549. select CRC32
  550. ---help---
  551. Fibre Channel library module
  552. config LIBFCOE
  553. tristate "LibFCoE module"
  554. select LIBFC
  555. ---help---
  556. Library for Fibre Channel over Ethernet module
  557. config FCOE
  558. tristate "FCoE module"
  559. depends on PCI
  560. select LIBFCOE
  561. ---help---
  562. Fibre Channel over Ethernet module
  563. config FCOE_FNIC
  564. tristate "Cisco FNIC Driver"
  565. depends on PCI && X86
  566. select LIBFCOE
  567. help
  568. This is support for the Cisco PCI-Express FCoE HBA.
  569. To compile this driver as a module, choose M here and read
  570. <file:Documentation/scsi/scsi.txt>.
  571. The module will be called fnic.
  572. config SCSI_DMX3191D
  573. tristate "DMX3191D SCSI support"
  574. depends on PCI && SCSI
  575. select SCSI_SPI_ATTRS
  576. help
  577. This is support for Domex DMX3191D SCSI Host Adapters.
  578. To compile this driver as a module, choose M here: the
  579. module will be called dmx3191d.
  580. config SCSI_DTC3280
  581. tristate "DTC3180/3280 SCSI support"
  582. depends on ISA && SCSI
  583. select SCSI_SPI_ATTRS
  584. select CHECK_SIGNATURE
  585. help
  586. This is support for DTC 3180/3280 SCSI Host Adapters. Please read
  587. the SCSI-HOWTO, available from
  588. <http://www.tldp.org/docs.html#howto>, and the file
  589. <file:Documentation/scsi/dtc3x80.txt>.
  590. To compile this driver as a module, choose M here: the
  591. module will be called dtc.
  592. config SCSI_EATA
  593. tristate "EATA ISA/EISA/PCI (DPT and generic EATA/DMA-compliant boards) support"
  594. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  595. ---help---
  596. This driver supports all EATA/DMA-compliant SCSI host adapters. DPT
  597. ISA and all EISA I/O addresses are probed looking for the "EATA"
  598. signature. The addresses of all the PCI SCSI controllers reported
  599. by the PCI subsystem are probed as well.
  600. You want to read the start of <file:drivers/scsi/eata.c> and the
  601. SCSI-HOWTO, available from
  602. <http://www.tldp.org/docs.html#howto>.
  603. To compile this driver as a module, choose M here: the
  604. module will be called eata.
  605. config SCSI_EATA_TAGGED_QUEUE
  606. bool "enable tagged command queueing"
  607. depends on SCSI_EATA
  608. help
  609. This is a feature of SCSI-2 which improves performance: the host
  610. adapter can send several SCSI commands to a device's queue even if
  611. previous commands haven't finished yet.
  612. This is equivalent to the "eata=tc:y" boot option.
  613. config SCSI_EATA_LINKED_COMMANDS
  614. bool "enable elevator sorting"
  615. depends on SCSI_EATA
  616. help
  617. This option enables elevator sorting for all probed SCSI disks and
  618. CD-ROMs. It definitely reduces the average seek distance when doing
  619. random seeks, but this does not necessarily result in a noticeable
  620. performance improvement: your mileage may vary...
  621. This is equivalent to the "eata=lc:y" boot option.
  622. config SCSI_EATA_MAX_TAGS
  623. int "maximum number of queued commands"
  624. depends on SCSI_EATA
  625. default "16"
  626. help
  627. This specifies how many SCSI commands can be maximally queued for
  628. each probed SCSI device. You should reduce the default value of 16
  629. only if you have disks with buggy or limited tagged command support.
  630. Minimum is 2 and maximum is 62. This value is also the window size
  631. used by the elevator sorting option above. The effective value used
  632. by the driver for each probed SCSI device is reported at boot time.
  633. This is equivalent to the "eata=mq:8" boot option.
  634. config SCSI_EATA_PIO
  635. tristate "EATA-PIO (old DPT PM2001, PM2012A) support"
  636. depends on (ISA || EISA || PCI) && SCSI && BROKEN
  637. ---help---
  638. This driver supports all EATA-PIO protocol compliant SCSI Host
  639. Adapters like the DPT PM2001 and the PM2012A. EATA-DMA compliant
  640. host adapters could also use this driver but are discouraged from
  641. doing so, since this driver only supports hard disks and lacks
  642. numerous features. You might want to have a look at the SCSI-HOWTO,
  643. available from <http://www.tldp.org/docs.html#howto>.
  644. To compile this driver as a module, choose M here: the
  645. module will be called eata_pio.
  646. config SCSI_FUTURE_DOMAIN
  647. tristate "Future Domain 16xx SCSI/AHA-2920A support"
  648. depends on (ISA || PCI) && SCSI
  649. select CHECK_SIGNATURE
  650. ---help---
  651. This is support for Future Domain's 16-bit SCSI host adapters
  652. (TMC-1660/1680, TMC-1650/1670, TMC-3260, TMC-1610M/MER/MEX) and
  653. other adapters based on the Future Domain chipsets (Quantum
  654. ISA-200S, ISA-250MG; Adaptec AHA-2920A; and at least one IBM board).
  655. It is explained in section 3.7 of the SCSI-HOWTO, available from
  656. <http://www.tldp.org/docs.html#howto>.
  657. NOTE: Newer Adaptec AHA-2920C boards use the Adaptec AIC-7850 chip
  658. and should use the aic7xxx driver ("Adaptec AIC7xxx chipset SCSI
  659. controller support"). This Future Domain driver works with the older
  660. Adaptec AHA-2920A boards with a Future Domain chip on them.
  661. To compile this driver as a module, choose M here: the
  662. module will be called fdomain.
  663. config SCSI_FD_MCS
  664. tristate "Future Domain MCS-600/700 SCSI support"
  665. depends on MCA_LEGACY && SCSI
  666. ---help---
  667. This is support for Future Domain MCS 600/700 MCA SCSI adapters.
  668. Some PS/2 computers are equipped with IBM Fast SCSI Adapter/A which
  669. is identical to the MCS 700 and hence also supported by this driver.
  670. This driver also supports the Reply SB16/SCSI card (the SCSI part).
  671. It supports multiple adapters in the same system.
  672. To compile this driver as a module, choose M here: the
  673. module will be called fd_mcs.
  674. config SCSI_GDTH
  675. tristate "Intel/ICP (former GDT SCSI Disk Array) RAID Controller support"
  676. depends on (ISA || EISA || PCI) && SCSI && ISA_DMA_API
  677. ---help---
  678. Formerly called GDT SCSI Disk Array Controller Support.
  679. This is a driver for RAID/SCSI Disk Array Controllers (EISA/ISA/PCI)
  680. manufactured by Intel Corporation/ICP vortex GmbH. It is documented
  681. in the kernel source in <file:drivers/scsi/gdth.c> and
  682. <file:drivers/scsi/gdth.h>.
  683. To compile this driver as a module, choose M here: the
  684. module will be called gdth.
  685. config SCSI_GENERIC_NCR5380
  686. tristate "Generic NCR5380/53c400 SCSI PIO support"
  687. depends on ISA && SCSI
  688. select SCSI_SPI_ATTRS
  689. ---help---
  690. This is a driver for the old NCR 53c80 series of SCSI controllers
  691. on boards using PIO. Most boards such as the Trantor T130 fit this
  692. category, along with a large number of ISA 8bit controllers shipped
  693. for free with SCSI scanners. If you have a PAS16, T128 or DMX3191
  694. you should select the specific driver for that card rather than
  695. generic 5380 support.
  696. It is explained in section 3.8 of the SCSI-HOWTO, available from
  697. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  698. of the box, you may have to change some settings in
  699. <file:drivers/scsi/g_NCR5380.h>.
  700. To compile this driver as a module, choose M here: the
  701. module will be called g_NCR5380.
  702. config SCSI_GENERIC_NCR5380_MMIO
  703. tristate "Generic NCR5380/53c400 SCSI MMIO support"
  704. depends on ISA && SCSI
  705. select SCSI_SPI_ATTRS
  706. ---help---
  707. This is a driver for the old NCR 53c80 series of SCSI controllers
  708. on boards using memory mapped I/O.
  709. It is explained in section 3.8 of the SCSI-HOWTO, available from
  710. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  711. of the box, you may have to change some settings in
  712. <file:drivers/scsi/g_NCR5380.h>.
  713. To compile this driver as a module, choose M here: the
  714. module will be called g_NCR5380_mmio.
  715. config SCSI_GENERIC_NCR53C400
  716. bool "Enable NCR53c400 extensions"
  717. depends on SCSI_GENERIC_NCR5380
  718. help
  719. This enables certain optimizations for the NCR53c400 SCSI cards.
  720. You might as well try it out. Note that this driver will only probe
  721. for the Trantor T130B in its default configuration; you might have
  722. to pass a command line option to the kernel at boot time if it does
  723. not detect your card. See the file
  724. <file:Documentation/scsi/g_NCR5380.txt> for details.
  725. config SCSI_IBMMCA
  726. tristate "IBMMCA SCSI support"
  727. depends on MCA && SCSI
  728. ---help---
  729. This is support for the IBM SCSI adapter found in many of the PS/2
  730. series computers. These machines have an MCA bus, so you need to
  731. answer Y to "MCA support" as well and read
  732. <file:Documentation/mca.txt>.
  733. If the adapter isn't found during boot (a common problem for models
  734. 56, 57, 76, and 77) you'll need to use the 'ibmmcascsi=<pun>' kernel
  735. option, where <pun> is the id of the SCSI subsystem (usually 7, but
  736. if that doesn't work check your reference diskette). Owners of
  737. model 95 with a LED-matrix-display can in addition activate some
  738. activity info like under OS/2, but more informative, by setting
  739. 'ibmmcascsi=display' as an additional kernel parameter. Try "man
  740. bootparam" or see the documentation of your boot loader about how to
  741. pass options to the kernel.
  742. To compile this driver as a module, choose M here: the
  743. module will be called ibmmca.
  744. config IBMMCA_SCSI_ORDER_STANDARD
  745. bool "Standard SCSI-order"
  746. depends on SCSI_IBMMCA
  747. ---help---
  748. In the PC-world and in most modern SCSI-BIOS-setups, SCSI-hard disks
  749. are assigned to the drive letters, starting with the lowest SCSI-id
  750. (physical number -- pun) to be drive C:, as seen from DOS and
  751. similar operating systems. When looking into papers describing the
  752. ANSI-SCSI-standard, this assignment of drives appears to be wrong.
  753. The SCSI-standard follows a hardware-hierarchy which says that id 7
  754. has the highest priority and id 0 the lowest. Therefore, the host
  755. adapters are still today everywhere placed as SCSI-id 7 by default.
  756. In the SCSI-standard, the drive letters express the priority of the
  757. disk. C: should be the hard disk, or a partition on it, with the
  758. highest priority. This must therefore be the disk with the highest
  759. SCSI-id (e.g. 6) and not the one with the lowest! IBM-BIOS kept the
  760. original definition of the SCSI-standard as also industrial- and
  761. process-control-machines, like VME-CPUs running under realtime-OSes
  762. (e.g. LynxOS, OS9) do.
  763. If you like to run Linux on your MCA-machine with the same
  764. assignment of hard disks as seen from e.g. DOS or OS/2 on your
  765. machine, which is in addition conformant to the SCSI-standard, you
  766. must say Y here. This is also necessary for MCA-Linux users who want
  767. to keep downward compatibility to older releases of the
  768. IBM-MCA-SCSI-driver (older than driver-release 2.00 and older than
  769. June 1997).
  770. If you like to have the lowest SCSI-id assigned as drive C:, as
  771. modern SCSI-BIOSes do, which does not conform to the standard, but
  772. is widespread and common in the PC-world of today, you must say N
  773. here. If unsure, say Y.
  774. config IBMMCA_SCSI_DEV_RESET
  775. bool "Reset SCSI-devices at boottime"
  776. depends on SCSI_IBMMCA
  777. ---help---
  778. By default, SCSI-devices are reset when the machine is powered on.
  779. However, some devices exist, like special-control-devices,
  780. SCSI-CNC-machines, SCSI-printer or scanners of older type, that do
  781. not reset when switched on. If you say Y here, each device connected
  782. to your SCSI-bus will be issued a reset-command after it has been
  783. probed, while the kernel is booting. This may cause problems with
  784. more modern devices, like hard disks, which do not appreciate these
  785. reset commands, and can cause your system to hang. So say Y only if
  786. you know that one of your older devices needs it; N is the safe
  787. answer.
  788. config SCSI_IPS
  789. tristate "IBM ServeRAID support"
  790. depends on PCI && SCSI
  791. ---help---
  792. This is support for the IBM ServeRAID hardware RAID controllers.
  793. See <http://www.developer.ibm.com/welcome/netfinity/serveraid.html>
  794. for more information. If this driver does not work correctly
  795. without modification please contact the author by email at
  796. <ipslinux@adaptec.com>.
  797. To compile this driver as a module, choose M here: the
  798. module will be called ips.
  799. config SCSI_IBMVSCSI
  800. tristate "IBM Virtual SCSI support"
  801. depends on PPC_PSERIES || PPC_ISERIES
  802. select SCSI_SRP_ATTRS
  803. select VIOPATH if PPC_ISERIES
  804. help
  805. This is the IBM POWER Virtual SCSI Client
  806. To compile this driver as a module, choose M here: the
  807. module will be called ibmvscsic.
  808. config SCSI_IBMVSCSIS
  809. tristate "IBM Virtual SCSI Server support"
  810. depends on PPC_PSERIES && SCSI_SRP && SCSI_SRP_TGT_ATTRS
  811. help
  812. This is the SRP target driver for IBM pSeries virtual environments.
  813. The userspace component needed to initialize the driver and
  814. documentation can be found:
  815. http://stgt.berlios.de/
  816. To compile this driver as a module, choose M here: the
  817. module will be called ibmvstgt.
  818. config SCSI_IBMVFC
  819. tristate "IBM Virtual FC support"
  820. depends on PPC_PSERIES && SCSI
  821. select SCSI_FC_ATTRS
  822. help
  823. This is the IBM POWER Virtual FC Client
  824. To compile this driver as a module, choose M here: the
  825. module will be called ibmvfc.
  826. config SCSI_IBMVFC_TRACE
  827. bool "enable driver internal trace"
  828. depends on SCSI_IBMVFC
  829. default y
  830. help
  831. If you say Y here, the driver will trace all commands issued
  832. to the adapter. Performance impact is minimal. Trace can be
  833. dumped using /sys/class/scsi_host/hostXX/trace.
  834. config SCSI_INITIO
  835. tristate "Initio 9100U(W) support"
  836. depends on PCI && SCSI
  837. help
  838. This is support for the Initio 91XXU(W) SCSI host adapter. Please
  839. read the SCSI-HOWTO, available from
  840. <http://www.tldp.org/docs.html#howto>.
  841. To compile this driver as a module, choose M here: the
  842. module will be called initio.
  843. config SCSI_INIA100
  844. tristate "Initio INI-A100U2W support"
  845. depends on PCI && SCSI
  846. help
  847. This is support for the Initio INI-A100U2W SCSI host adapter.
  848. Please read the SCSI-HOWTO, available from
  849. <http://www.tldp.org/docs.html#howto>.
  850. To compile this driver as a module, choose M here: the
  851. module will be called a100u2w.
  852. config SCSI_PPA
  853. tristate "IOMEGA parallel port (ppa - older drives)"
  854. depends on SCSI && PARPORT_PC
  855. ---help---
  856. This driver supports older versions of IOMEGA's parallel port ZIP
  857. drive (a 100 MB removable media device).
  858. Note that you can say N here if you have the SCSI version of the ZIP
  859. drive: it will be supported automatically if you said Y to the
  860. generic "SCSI disk support", above.
  861. If you have the ZIP Plus drive or a more recent parallel port ZIP
  862. drive (if the supplied cable with the drive is labeled "AutoDetect")
  863. then you should say N here and Y to "IOMEGA parallel port (imm -
  864. newer drives)", below.
  865. For more information about this driver and how to use it you should
  866. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  867. the SCSI-HOWTO, which is available from
  868. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  869. you will still be able to use the parallel port for other tasks,
  870. such as a printer; it is safe to compile both drivers into the
  871. kernel.
  872. To compile this driver as a module, choose M here: the
  873. module will be called ppa.
  874. config SCSI_IMM
  875. tristate "IOMEGA parallel port (imm - newer drives)"
  876. depends on SCSI && PARPORT_PC
  877. ---help---
  878. This driver supports newer versions of IOMEGA's parallel port ZIP
  879. drive (a 100 MB removable media device).
  880. Note that you can say N here if you have the SCSI version of the ZIP
  881. drive: it will be supported automatically if you said Y to the
  882. generic "SCSI disk support", above.
  883. If you have the ZIP Plus drive or a more recent parallel port ZIP
  884. drive (if the supplied cable with the drive is labeled "AutoDetect")
  885. then you should say Y here; if you have an older ZIP drive, say N
  886. here and Y to "IOMEGA Parallel Port (ppa - older drives)", above.
  887. For more information about this driver and how to use it you should
  888. read the file <file:Documentation/scsi/ppa.txt>. You should also read
  889. the SCSI-HOWTO, which is available from
  890. <http://www.tldp.org/docs.html#howto>. If you use this driver,
  891. you will still be able to use the parallel port for other tasks,
  892. such as a printer; it is safe to compile both drivers into the
  893. kernel.
  894. To compile this driver as a module, choose M here: the
  895. module will be called imm.
  896. config SCSI_IZIP_EPP16
  897. bool "ppa/imm option - Use slow (but safe) EPP-16"
  898. depends on SCSI_PPA || SCSI_IMM
  899. ---help---
  900. EPP (Enhanced Parallel Port) is a standard for parallel ports which
  901. allows them to act as expansion buses that can handle up to 64
  902. peripheral devices.
  903. Some parallel port chipsets are slower than their motherboard, and
  904. so we have to control the state of the chipset's FIFO queue every
  905. now and then to avoid data loss. This will be done if you say Y
  906. here.
  907. Generally, saying Y is the safe option and slows things down a bit.
  908. config SCSI_IZIP_SLOW_CTR
  909. bool "ppa/imm option - Assume slow parport control register"
  910. depends on SCSI_PPA || SCSI_IMM
  911. help
  912. Some parallel ports are known to have excessive delays between
  913. changing the parallel port control register and good data being
  914. available on the parallel port data/status register. This option
  915. forces a small delay (1.0 usec to be exact) after changing the
  916. control register to let things settle out. Enabling this option may
  917. result in a big drop in performance but some very old parallel ports
  918. (found in 386 vintage machines) will not work properly.
  919. Generally, saying N is fine.
  920. config SCSI_NCR53C406A
  921. tristate "NCR53c406a SCSI support"
  922. depends on ISA && SCSI
  923. help
  924. This is support for the NCR53c406a SCSI host adapter. For user
  925. configurable parameters, check out <file:drivers/scsi/NCR53c406a.c>
  926. in the kernel source. Also read the SCSI-HOWTO, available from
  927. <http://www.tldp.org/docs.html#howto>.
  928. To compile this driver as a module, choose M here: the
  929. module will be called NCR53c406.
  930. config SCSI_NCR_D700
  931. tristate "NCR Dual 700 MCA SCSI support"
  932. depends on MCA && SCSI
  933. select SCSI_SPI_ATTRS
  934. help
  935. This is a driver for the MicroChannel Dual 700 card produced by
  936. NCR and commonly used in 345x/35xx/4100 class machines. It always
  937. tries to negotiate sync and uses tag command queueing.
  938. Unless you have an NCR manufactured machine, the chances are that
  939. you do not have this SCSI card, so say N.
  940. config SCSI_LASI700
  941. tristate "HP Lasi SCSI support for 53c700/710"
  942. depends on GSC && SCSI
  943. select SCSI_SPI_ATTRS
  944. help
  945. This is a driver for the SCSI controller in the Lasi chip found in
  946. many PA-RISC workstations & servers. If you do not know whether you
  947. have a Lasi chip, it is safe to say "Y" here.
  948. config SCSI_SNI_53C710
  949. tristate "SNI RM SCSI support for 53c710"
  950. depends on SNI_RM && SCSI
  951. select SCSI_SPI_ATTRS
  952. select 53C700_LE_ON_BE
  953. help
  954. This is a driver for the onboard SCSI controller found in older
  955. SNI RM workstations & servers.
  956. config 53C700_LE_ON_BE
  957. bool
  958. depends on SCSI_LASI700
  959. default y
  960. config SCSI_STEX
  961. tristate "Promise SuperTrak EX Series support"
  962. depends on PCI && SCSI
  963. ---help---
  964. This driver supports Promise SuperTrak EX series storage controllers.
  965. Promise provides Linux RAID configuration utility for these
  966. controllers. Please visit <http://www.promise.com> to download.
  967. To compile this driver as a module, choose M here: the
  968. module will be called stex.
  969. config 53C700_BE_BUS
  970. bool
  971. depends on SCSI_A4000T || SCSI_ZORRO7XX || MVME16x_SCSI || BVME6000_SCSI
  972. default y
  973. config SCSI_SYM53C8XX_2
  974. tristate "SYM53C8XX Version 2 SCSI support"
  975. depends on PCI && SCSI
  976. select SCSI_SPI_ATTRS
  977. ---help---
  978. This driver supports the whole NCR53C8XX/SYM53C8XX family of
  979. PCI-SCSI controllers. It also supports the subset of LSI53C10XX
  980. Ultra-160 controllers that are based on the SYM53C8XX SCRIPTS
  981. language. It does not support LSI53C10XX Ultra-320 PCI-X SCSI
  982. controllers; you need to use the Fusion MPT driver for that.
  983. Please read <file:Documentation/scsi/sym53c8xx_2.txt> for more
  984. information.
  985. config SCSI_SYM53C8XX_DMA_ADDRESSING_MODE
  986. int "DMA addressing mode"
  987. depends on SCSI_SYM53C8XX_2
  988. default "1"
  989. ---help---
  990. This option only applies to PCI-SCSI chips that are PCI DAC
  991. capable (875A, 895A, 896, 1010-33, 1010-66, 1000).
  992. When set to 0, the driver will program the chip to only perform
  993. 32-bit DMA. When set to 1, the chip will be able to perform DMA
  994. to addresses up to 1TB. When set to 2, the driver supports the
  995. full 64-bit DMA address range, but can only address 16 segments
  996. of 4 GB each. This limits the total addressable range to 64 GB.
  997. Most machines with less than 4GB of memory should use a setting
  998. of 0 for best performance. If your machine has 4GB of memory
  999. or more, you should set this option to 1 (the default).
  1000. The still experimental value 2 (64 bit DMA addressing with 16
  1001. x 4GB segments limitation) can be used on systems that require
  1002. PCI address bits past bit 39 to be set for the addressing of
  1003. memory using PCI DAC cycles.
  1004. config SCSI_SYM53C8XX_DEFAULT_TAGS
  1005. int "Default tagged command queue depth"
  1006. depends on SCSI_SYM53C8XX_2
  1007. default "16"
  1008. help
  1009. This is the default value of the command queue depth the
  1010. driver will announce to the generic SCSI layer for devices
  1011. that support tagged command queueing. This value can be changed
  1012. from the boot command line. This is a soft limit that cannot
  1013. exceed CONFIG_SCSI_SYM53C8XX_MAX_TAGS.
  1014. config SCSI_SYM53C8XX_MAX_TAGS
  1015. int "Maximum number of queued commands"
  1016. depends on SCSI_SYM53C8XX_2
  1017. default "64"
  1018. help
  1019. This option allows you to specify the maximum number of commands
  1020. that can be queued to any device, when tagged command queuing is
  1021. possible. The driver supports up to 256 queued commands per device.
  1022. This value is used as a compiled-in hard limit.
  1023. config SCSI_SYM53C8XX_MMIO
  1024. bool "Use memory mapped IO"
  1025. depends on SCSI_SYM53C8XX_2
  1026. default y
  1027. help
  1028. Memory mapped IO is faster than Port IO. Most people should
  1029. answer Y here, but some machines may have problems. If you have
  1030. to answer N here, please report the problem to the maintainer.
  1031. config SCSI_IPR
  1032. tristate "IBM Power Linux RAID adapter support"
  1033. depends on PCI && SCSI && ATA
  1034. select FW_LOADER
  1035. ---help---
  1036. This driver supports the IBM Power Linux family RAID adapters.
  1037. This includes IBM pSeries 5712, 5703, 5709, and 570A, as well
  1038. as IBM iSeries 5702, 5703, 5709, and 570A.
  1039. config SCSI_IPR_TRACE
  1040. bool "enable driver internal trace"
  1041. depends on SCSI_IPR
  1042. default y
  1043. help
  1044. If you say Y here, the driver will trace all commands issued
  1045. to the adapter. Performance impact is minimal. Trace can be
  1046. dumped using /sys/bus/class/scsi_host/hostXX/trace.
  1047. config SCSI_IPR_DUMP
  1048. bool "enable adapter dump support"
  1049. depends on SCSI_IPR
  1050. default y
  1051. help
  1052. If you say Y here, the driver will support adapter crash dump.
  1053. If you enable this support, the iprdump daemon can be used
  1054. to capture adapter failure analysis information.
  1055. config SCSI_ZALON
  1056. tristate "Zalon SCSI support"
  1057. depends on GSC && SCSI
  1058. select SCSI_SPI_ATTRS
  1059. help
  1060. The Zalon is a GSC/HSC bus interface chip that sits between the
  1061. PA-RISC processor and the NCR 53c720 SCSI controller on C100,
  1062. C110, J200, J210 and some D, K & R-class machines. It's also
  1063. used on the add-in Bluefish, Barracuda & Shrike SCSI cards.
  1064. Say Y here if you have one of these machines or cards.
  1065. config SCSI_NCR_Q720
  1066. tristate "NCR Quad 720 MCA SCSI support"
  1067. depends on MCA && SCSI
  1068. select SCSI_SPI_ATTRS
  1069. help
  1070. This is a driver for the MicroChannel Quad 720 card produced by
  1071. NCR and commonly used in 345x/35xx/4100 class machines. It always
  1072. tries to negotiate sync and uses tag command queueing.
  1073. Unless you have an NCR manufactured machine, the chances are that
  1074. you do not have this SCSI card, so say N.
  1075. config SCSI_NCR53C8XX_DEFAULT_TAGS
  1076. int "default tagged command queue depth"
  1077. depends on SCSI_ZALON || SCSI_NCR_Q720
  1078. default "8"
  1079. ---help---
  1080. "Tagged command queuing" is a feature of SCSI-2 which improves
  1081. performance: the host adapter can send several SCSI commands to a
  1082. device's queue even if previous commands haven't finished yet.
  1083. Because the device is intelligent, it can optimize its operations
  1084. (like head positioning) based on its own request queue. Some SCSI
  1085. devices don't implement this properly; if you want to disable this
  1086. feature, enter 0 or 1 here (it doesn't matter which).
  1087. The default value is 8 and should be supported by most hard disks.
  1088. This value can be overridden from the boot command line using the
  1089. 'tags' option as follows (example):
  1090. 'ncr53c8xx=tags:4/t2t3q16/t0u2q10' will set default queue depth to
  1091. 4, set queue depth to 16 for target 2 and target 3 on controller 0
  1092. and set queue depth to 10 for target 0 / lun 2 on controller 1.
  1093. The normal answer therefore is to go with the default 8 and to use
  1094. a boot command line option for devices that need to use a different
  1095. command queue depth.
  1096. There is no safe option other than using good SCSI devices.
  1097. config SCSI_NCR53C8XX_MAX_TAGS
  1098. int "maximum number of queued commands"
  1099. depends on SCSI_ZALON || SCSI_NCR_Q720
  1100. default "32"
  1101. ---help---
  1102. This option allows you to specify the maximum number of commands
  1103. that can be queued to any device, when tagged command queuing is
  1104. possible. The default value is 32. Minimum is 2, maximum is 64.
  1105. Modern hard disks are able to support 64 tags and even more, but
  1106. do not seem to be faster when more than 32 tags are being used.
  1107. So, the normal answer here is to go with the default value 32 unless
  1108. you are using very large hard disks with large cache (>= 1 MB) that
  1109. are able to take advantage of more than 32 tagged commands.
  1110. There is no safe option and the default answer is recommended.
  1111. config SCSI_NCR53C8XX_SYNC
  1112. int "synchronous transfers frequency in MHz"
  1113. depends on SCSI_ZALON || SCSI_NCR_Q720
  1114. default "20"
  1115. ---help---
  1116. The SCSI Parallel Interface-2 Standard defines 5 classes of transfer
  1117. rates: FAST-5, FAST-10, FAST-20, FAST-40 and FAST-80. The numbers
  1118. are respectively the maximum data transfer rates in mega-transfers
  1119. per second for each class. For example, a FAST-20 Wide 16 device is
  1120. able to transfer data at 20 million 16 bit packets per second for a
  1121. total rate of 40 MB/s.
  1122. You may specify 0 if you want to only use asynchronous data
  1123. transfers. This is the safest and slowest option. Otherwise, specify
  1124. a value between 5 and 80, depending on the capability of your SCSI
  1125. controller. The higher the number, the faster the data transfer.
  1126. Note that 80 should normally be ok since the driver decreases the
  1127. value automatically according to the controller's capabilities.
  1128. Your answer to this question is ignored for controllers with NVRAM,
  1129. since the driver will get this information from the user set-up. It
  1130. also can be overridden using a boot setup option, as follows
  1131. (example): 'ncr53c8xx=sync:12' will allow the driver to negotiate
  1132. for FAST-20 synchronous data transfer (20 mega-transfers per
  1133. second).
  1134. The normal answer therefore is not to go with the default but to
  1135. select the maximum value 80 allowing the driver to use the maximum
  1136. value supported by each controller. If this causes problems with
  1137. your SCSI devices, you should come back and decrease the value.
  1138. There is no safe option other than using good cabling, right
  1139. terminations and SCSI conformant devices.
  1140. config SCSI_NCR53C8XX_NO_DISCONNECT
  1141. bool "not allow targets to disconnect"
  1142. depends on (SCSI_ZALON || SCSI_NCR_Q720) && SCSI_NCR53C8XX_DEFAULT_TAGS=0
  1143. help
  1144. This option is only provided for safety if you suspect some SCSI
  1145. device of yours to not support properly the target-disconnect
  1146. feature. In that case, you would say Y here. In general however, to
  1147. not allow targets to disconnect is not reasonable if there is more
  1148. than 1 device on a SCSI bus. The normal answer therefore is N.
  1149. config SCSI_PAS16
  1150. tristate "PAS16 SCSI support"
  1151. depends on ISA && SCSI
  1152. select SCSI_SPI_ATTRS
  1153. ---help---
  1154. This is support for a SCSI host adapter. It is explained in section
  1155. 3.10 of the SCSI-HOWTO, available from
  1156. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1157. of the box, you may have to change some settings in
  1158. <file:drivers/scsi/pas16.h>.
  1159. To compile this driver as a module, choose M here: the
  1160. module will be called pas16.
  1161. config SCSI_QLOGIC_FAS
  1162. tristate "Qlogic FAS SCSI support"
  1163. depends on ISA && SCSI
  1164. ---help---
  1165. This is a driver for the ISA, VLB, and PCMCIA versions of the Qlogic
  1166. FastSCSI! cards as well as any other card based on the FASXX chip
  1167. (including the Control Concepts SCSI/IDE/SIO/PIO/FDC cards).
  1168. This driver does NOT support the PCI versions of these cards. The
  1169. PCI versions are supported by the Qlogic ISP driver ("Qlogic ISP
  1170. SCSI support"), below.
  1171. Information about this driver is contained in
  1172. <file:Documentation/scsi/qlogicfas.txt>. You should also read the
  1173. SCSI-HOWTO, available from
  1174. <http://www.tldp.org/docs.html#howto>.
  1175. To compile this driver as a module, choose M here: the
  1176. module will be called qlogicfas.
  1177. config SCSI_QLOGIC_1280
  1178. tristate "Qlogic QLA 1240/1x80/1x160 SCSI support"
  1179. depends on PCI && SCSI
  1180. help
  1181. Say Y if you have a QLogic ISP1240/1x80/1x160 SCSI host adapter.
  1182. To compile this driver as a module, choose M here: the
  1183. module will be called qla1280.
  1184. config SCSI_QLOGICPTI
  1185. tristate "PTI Qlogic, ISP Driver"
  1186. depends on SBUS && SCSI
  1187. help
  1188. This driver supports SBUS SCSI controllers from PTI or QLogic. These
  1189. controllers are known under Solaris as qpti and in the openprom as
  1190. PTI,ptisp or QLGC,isp. Note that PCI QLogic SCSI controllers are
  1191. driven by a different driver.
  1192. To compile this driver as a module, choose M here: the
  1193. module will be called qlogicpti.
  1194. source "drivers/scsi/qla2xxx/Kconfig"
  1195. source "drivers/scsi/qla4xxx/Kconfig"
  1196. config SCSI_LPFC
  1197. tristate "Emulex LightPulse Fibre Channel Support"
  1198. depends on PCI && SCSI
  1199. select SCSI_FC_ATTRS
  1200. help
  1201. This lpfc driver supports the Emulex LightPulse
  1202. Family of Fibre Channel PCI host adapters.
  1203. config SCSI_LPFC_DEBUG_FS
  1204. bool "Emulex LightPulse Fibre Channel debugfs Support"
  1205. depends on SCSI_LPFC && DEBUG_FS
  1206. help
  1207. This makes debugging information from the lpfc driver
  1208. available via the debugfs filesystem.
  1209. config SCSI_SIM710
  1210. tristate "Simple 53c710 SCSI support (Compaq, NCR machines)"
  1211. depends on (EISA || MCA) && SCSI
  1212. select SCSI_SPI_ATTRS
  1213. ---help---
  1214. This driver is for NCR53c710 based SCSI host adapters.
  1215. It currently supports Compaq EISA cards and NCR MCA cards
  1216. config SCSI_SYM53C416
  1217. tristate "Symbios 53c416 SCSI support"
  1218. depends on ISA && SCSI
  1219. ---help---
  1220. This is support for the sym53c416 SCSI host adapter, the SCSI
  1221. adapter that comes with some HP scanners. This driver requires that
  1222. the sym53c416 is configured first using some sort of PnP
  1223. configuration program (e.g. isapnp) or by a PnP aware BIOS. If you
  1224. are using isapnp then you need to compile this driver as a module
  1225. and then load it using insmod after isapnp has run. The parameters
  1226. of the configured card(s) should be passed to the driver. The format
  1227. is:
  1228. insmod sym53c416 sym53c416=<base>,<irq> [sym53c416_1=<base>,<irq>]
  1229. To compile this driver as a module, choose M here: the
  1230. module will be called sym53c416.
  1231. config SCSI_DC395x
  1232. tristate "Tekram DC395(U/UW/F) and DC315(U) SCSI support (EXPERIMENTAL)"
  1233. depends on PCI && SCSI && EXPERIMENTAL
  1234. ---help---
  1235. This driver supports PCI SCSI host adapters based on the ASIC
  1236. TRM-S1040 chip, e.g Tekram DC395(U/UW/F) and DC315(U) variants.
  1237. This driver works, but is still in experimental status. So better
  1238. have a bootable disk and a backup in case of emergency.
  1239. Documentation can be found in <file:Documentation/scsi/dc395x.txt>.
  1240. To compile this driver as a module, choose M here: the
  1241. module will be called dc395x.
  1242. config SCSI_DC390T
  1243. tristate "Tekram DC390(T) and Am53/79C974 SCSI support"
  1244. depends on PCI && SCSI
  1245. ---help---
  1246. This driver supports PCI SCSI host adapters based on the Am53C974A
  1247. chip, e.g. Tekram DC390(T), DawiControl 2974 and some onboard
  1248. PCscsi/PCnet (Am53/79C974) solutions.
  1249. Documentation can be found in <file:Documentation/scsi/tmscsim.txt>.
  1250. Note that this driver does NOT support Tekram DC390W/U/F, which are
  1251. based on NCR/Symbios chips. Use "NCR53C8XX SCSI support" for those.
  1252. To compile this driver as a module, choose M here: the
  1253. module will be called tmscsim.
  1254. config SCSI_T128
  1255. tristate "Trantor T128/T128F/T228 SCSI support"
  1256. depends on ISA && SCSI
  1257. select SCSI_SPI_ATTRS
  1258. select CHECK_SIGNATURE
  1259. ---help---
  1260. This is support for a SCSI host adapter. It is explained in section
  1261. 3.11 of the SCSI-HOWTO, available from
  1262. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1263. of the box, you may have to change some settings in
  1264. <file:drivers/scsi/t128.h>. Note that Trantor was purchased by
  1265. Adaptec, and some former Trantor products are being sold under the
  1266. Adaptec name.
  1267. To compile this driver as a module, choose M here: the
  1268. module will be called t128.
  1269. config SCSI_U14_34F
  1270. tristate "UltraStor 14F/34F support"
  1271. depends on ISA && SCSI && ISA_DMA_API
  1272. ---help---
  1273. This is support for the UltraStor 14F and 34F SCSI-2 host adapters.
  1274. The source at <file:drivers/scsi/u14-34f.c> contains some
  1275. information about this hardware. If the driver doesn't work out of
  1276. the box, you may have to change some settings in
  1277. <file: drivers/scsi/u14-34f.c>. Read the SCSI-HOWTO, available from
  1278. <http://www.tldp.org/docs.html#howto>. Note that there is also
  1279. another driver for the same hardware: "UltraStor SCSI support",
  1280. below. You should say Y to both only if you want 24F support as
  1281. well.
  1282. To compile this driver as a module, choose M here: the
  1283. module will be called u14-34f.
  1284. config SCSI_U14_34F_TAGGED_QUEUE
  1285. bool "enable tagged command queueing"
  1286. depends on SCSI_U14_34F
  1287. help
  1288. This is a feature of SCSI-2 which improves performance: the host
  1289. adapter can send several SCSI commands to a device's queue even if
  1290. previous commands haven't finished yet.
  1291. This is equivalent to the "u14-34f=tc:y" boot option.
  1292. config SCSI_U14_34F_LINKED_COMMANDS
  1293. bool "enable elevator sorting"
  1294. depends on SCSI_U14_34F
  1295. help
  1296. This option enables elevator sorting for all probed SCSI disks and
  1297. CD-ROMs. It definitely reduces the average seek distance when doing
  1298. random seeks, but this does not necessarily result in a noticeable
  1299. performance improvement: your mileage may vary...
  1300. This is equivalent to the "u14-34f=lc:y" boot option.
  1301. config SCSI_U14_34F_MAX_TAGS
  1302. int "maximum number of queued commands"
  1303. depends on SCSI_U14_34F
  1304. default "8"
  1305. help
  1306. This specifies how many SCSI commands can be maximally queued for
  1307. each probed SCSI device. You should reduce the default value of 8
  1308. only if you have disks with buggy or limited tagged command support.
  1309. Minimum is 2 and maximum is 14. This value is also the window size
  1310. used by the elevator sorting option above. The effective value used
  1311. by the driver for each probed SCSI device is reported at boot time.
  1312. This is equivalent to the "u14-34f=mq:8" boot option.
  1313. config SCSI_ULTRASTOR
  1314. tristate "UltraStor SCSI support"
  1315. depends on X86 && ISA && SCSI
  1316. ---help---
  1317. This is support for the UltraStor 14F, 24F and 34F SCSI-2 host
  1318. adapter family. This driver is explained in section 3.12 of the
  1319. SCSI-HOWTO, available from
  1320. <http://www.tldp.org/docs.html#howto>. If it doesn't work out
  1321. of the box, you may have to change some settings in
  1322. <file:drivers/scsi/ultrastor.h>.
  1323. Note that there is also another driver for the same hardware:
  1324. "UltraStor 14F/34F support", above.
  1325. To compile this driver as a module, choose M here: the
  1326. module will be called ultrastor.
  1327. config SCSI_NSP32
  1328. tristate "Workbit NinjaSCSI-32Bi/UDE support"
  1329. depends on PCI && SCSI && !64BIT
  1330. help
  1331. This is support for the Workbit NinjaSCSI-32Bi/UDE PCI/Cardbus
  1332. SCSI host adapter. Please read the SCSI-HOWTO, available from
  1333. <http://www.tldp.org/docs.html#howto>.
  1334. To compile this driver as a module, choose M here: the
  1335. module will be called nsp32.
  1336. config SCSI_DEBUG
  1337. tristate "SCSI debugging host simulator"
  1338. depends on SCSI
  1339. select CRC_T10DIF
  1340. help
  1341. This is a host adapter simulator that can simulate multiple hosts
  1342. each with multiple dummy SCSI devices (disks). It defaults to one
  1343. host adapter with one dummy SCSI disk. Each dummy disk uses kernel
  1344. RAM as storage (i.e. it is a ramdisk). To save space when multiple
  1345. dummy disks are simulated, they share the same kernel RAM for
  1346. their storage. See <http://www.torque.net/sg/sdebug.html> for more
  1347. information. This driver is primarily of use to those testing the
  1348. SCSI and block subsystems. If unsure, say N.
  1349. config SCSI_MESH
  1350. tristate "MESH (Power Mac internal SCSI) support"
  1351. depends on PPC32 && PPC_PMAC && SCSI
  1352. help
  1353. Many Power Macintoshes and clones have a MESH (Macintosh Enhanced
  1354. SCSI Hardware) SCSI bus adaptor (the 7200 doesn't, but all of the
  1355. other Power Macintoshes do). Say Y to include support for this SCSI
  1356. adaptor.
  1357. To compile this driver as a module, choose M here: the
  1358. module will be called mesh.
  1359. config SCSI_MESH_SYNC_RATE
  1360. int "maximum synchronous transfer rate (MB/s) (0 = async)"
  1361. depends on SCSI_MESH
  1362. default "5"
  1363. help
  1364. On Power Macintoshes (and clones) where the MESH SCSI bus adaptor
  1365. drives a bus which is entirely internal to the machine (such as the
  1366. 7500, 7600, 8500, etc.), the MESH is capable of synchronous
  1367. operation at up to 10 MB/s. On machines where the SCSI bus
  1368. controlled by the MESH can have external devices connected, it is
  1369. usually rated at 5 MB/s. 5 is a safe value here unless you know the
  1370. MESH SCSI bus is internal only; in that case you can say 10. Say 0
  1371. to disable synchronous operation.
  1372. config SCSI_MESH_RESET_DELAY_MS
  1373. int "initial bus reset delay (ms) (0 = no reset)"
  1374. depends on SCSI_MESH
  1375. default "4000"
  1376. config SCSI_MAC53C94
  1377. tristate "53C94 (Power Mac external SCSI) support"
  1378. depends on PPC32 && PPC_PMAC && SCSI
  1379. help
  1380. On Power Macintoshes (and clones) with two SCSI buses, the external
  1381. SCSI bus is usually controlled by a 53C94 SCSI bus adaptor. Older
  1382. machines which only have one SCSI bus, such as the 7200, also use
  1383. the 53C94. Say Y to include support for the 53C94.
  1384. To compile this driver as a module, choose M here: the
  1385. module will be called mac53c94.
  1386. source "drivers/scsi/arm/Kconfig"
  1387. config JAZZ_ESP
  1388. bool "MIPS JAZZ FAS216 SCSI support"
  1389. depends on MACH_JAZZ && SCSI
  1390. select SCSI_SPI_ATTRS
  1391. help
  1392. This is the driver for the onboard SCSI host adapter of MIPS Magnum
  1393. 4000, Acer PICA, Olivetti M700-10 and a few other identical OEM
  1394. systems.
  1395. config A3000_SCSI
  1396. tristate "A3000 WD33C93A support"
  1397. depends on AMIGA && SCSI
  1398. help
  1399. If you have an Amiga 3000 and have SCSI devices connected to the
  1400. built-in SCSI controller, say Y. Otherwise, say N.
  1401. To compile this driver as a module, choose M here: the
  1402. module will be called a3000.
  1403. config A2091_SCSI
  1404. tristate "A2091/A590 WD33C93A support"
  1405. depends on ZORRO && SCSI
  1406. help
  1407. If you have a Commodore A2091 SCSI controller, say Y. Otherwise,
  1408. say N.
  1409. To compile this driver as a module, choose M here: the
  1410. module will be called a2091.
  1411. config GVP11_SCSI
  1412. tristate "GVP Series II WD33C93A support"
  1413. depends on ZORRO && SCSI
  1414. ---help---
  1415. If you have a Great Valley Products Series II SCSI controller,
  1416. answer Y. Also say Y if you have a later model of GVP SCSI
  1417. controller (such as the GVP A4008 or a Combo board). Otherwise,
  1418. answer N. This driver does NOT work for the T-Rex series of
  1419. accelerators from TekMagic and GVP-M.
  1420. To compile this driver as a module, choose M here: the
  1421. module will be called gvp11.
  1422. config SCSI_A4000T
  1423. tristate "A4000T NCR53c710 SCSI support (EXPERIMENTAL)"
  1424. depends on AMIGA && SCSI && EXPERIMENTAL
  1425. select SCSI_SPI_ATTRS
  1426. help
  1427. If you have an Amiga 4000T and have SCSI devices connected to the
  1428. built-in SCSI controller, say Y. Otherwise, say N.
  1429. To compile this driver as a module, choose M here: the
  1430. module will be called a4000t.
  1431. config SCSI_ZORRO7XX
  1432. tristate "Zorro NCR53c710 SCSI support (EXPERIMENTAL)"
  1433. depends on ZORRO && SCSI && EXPERIMENTAL
  1434. select SCSI_SPI_ATTRS
  1435. help
  1436. Support for various NCR53c710-based SCSI controllers on Zorro
  1437. expansion boards for the Amiga.
  1438. This includes:
  1439. - the Amiga 4091 Zorro III SCSI-2 controller,
  1440. - the MacroSystem Development's WarpEngine Amiga SCSI-2 controller
  1441. (info at
  1442. <http://www.lysator.liu.se/amiga/ar/guide/ar310.guide?FEATURE5>),
  1443. - the SCSI controller on the Phase5 Blizzard PowerUP 603e+
  1444. accelerator card for the Amiga 1200,
  1445. - the SCSI controller on the GVP Turbo 040/060 accelerator.
  1446. config ATARI_SCSI
  1447. tristate "Atari native SCSI support"
  1448. depends on ATARI && SCSI
  1449. select SCSI_SPI_ATTRS
  1450. select NVRAM
  1451. ---help---
  1452. If you have an Atari with built-in NCR5380 SCSI controller (TT,
  1453. Falcon, ...) say Y to get it supported. Of course also, if you have
  1454. a compatible SCSI controller (e.g. for Medusa).
  1455. To compile this driver as a module, choose M here: the
  1456. module will be called atari_scsi.
  1457. This driver supports both styles of NCR integration into the
  1458. system: the TT style (separate DMA), and the Falcon style (via
  1459. ST-DMA, replacing ACSI). It does NOT support other schemes, like
  1460. in the Hades (without DMA).
  1461. config ATARI_SCSI_TOSHIBA_DELAY
  1462. bool "Long delays for Toshiba CD-ROMs"
  1463. depends on ATARI_SCSI
  1464. help
  1465. This option increases the delay after a SCSI arbitration to
  1466. accommodate some flaky Toshiba CD-ROM drives. Say Y if you intend to
  1467. use a Toshiba CD-ROM drive; otherwise, the option is not needed and
  1468. would impact performance a bit, so say N.
  1469. config ATARI_SCSI_RESET_BOOT
  1470. bool "Reset SCSI-devices at boottime"
  1471. depends on ATARI_SCSI
  1472. help
  1473. Reset the devices on your Atari whenever it boots. This makes the
  1474. boot process fractionally longer but may assist recovery from errors
  1475. that leave the devices with SCSI operations partway completed.
  1476. config MAC_SCSI
  1477. bool "Macintosh NCR5380 SCSI"
  1478. depends on MAC && SCSI=y
  1479. select SCSI_SPI_ATTRS
  1480. help
  1481. This is the NCR 5380 SCSI controller included on most of the 68030
  1482. based Macintoshes. If you have one of these say Y and read the
  1483. SCSI-HOWTO, available from
  1484. <http://www.tldp.org/docs.html#howto>.
  1485. config SCSI_MAC_ESP
  1486. tristate "Macintosh NCR53c9[46] SCSI"
  1487. depends on MAC && SCSI
  1488. select SCSI_SPI_ATTRS
  1489. help
  1490. This is the NCR 53c9x SCSI controller found on most of the 68040
  1491. based Macintoshes.
  1492. To compile this driver as a module, choose M here: the module
  1493. will be called mac_esp.
  1494. config MVME147_SCSI
  1495. bool "WD33C93 SCSI driver for MVME147"
  1496. depends on MVME147 && SCSI=y
  1497. select SCSI_SPI_ATTRS
  1498. help
  1499. Support for the on-board SCSI controller on the Motorola MVME147
  1500. single-board computer.
  1501. config MVME16x_SCSI
  1502. tristate "NCR53C710 SCSI driver for MVME16x"
  1503. depends on MVME16x && SCSI
  1504. select SCSI_SPI_ATTRS
  1505. help
  1506. The Motorola MVME162, 166, 167, 172 and 177 boards use the NCR53C710
  1507. SCSI controller chip. Almost everyone using one of these boards
  1508. will want to say Y to this question.
  1509. config BVME6000_SCSI
  1510. tristate "NCR53C710 SCSI driver for BVME6000"
  1511. depends on BVME6000 && SCSI
  1512. select SCSI_SPI_ATTRS
  1513. help
  1514. The BVME4000 and BVME6000 boards from BVM Ltd use the NCR53C710
  1515. SCSI controller chip. Almost everyone using one of these boards
  1516. will want to say Y to this question.
  1517. config SUN3_SCSI
  1518. tristate "Sun3 NCR5380 SCSI"
  1519. depends on SUN3 && SCSI
  1520. select SCSI_SPI_ATTRS
  1521. help
  1522. This option will enable support for the OBIO (onboard io) NCR5380
  1523. SCSI controller found in the Sun 3/50 and 3/60, as well as for
  1524. "Sun3" type VME scsi controllers also based on the NCR5380.
  1525. General Linux information on the Sun 3 series (now discontinued)
  1526. is at <http://www.angelfire.com/ca2/tech68k/sun3.html>.
  1527. config SUN3X_ESP
  1528. bool "Sun3x ESP SCSI"
  1529. depends on SUN3X && SCSI=y
  1530. select SCSI_SPI_ATTRS
  1531. help
  1532. The ESP was an on-board SCSI controller used on Sun 3/80
  1533. machines. Say Y here to compile in support for it.
  1534. config SCSI_SUNESP
  1535. tristate "Sparc ESP Scsi Driver"
  1536. depends on SBUS && SCSI
  1537. select SCSI_SPI_ATTRS
  1538. help
  1539. This is the driver for the Sun ESP SCSI host adapter. The ESP
  1540. chipset is present in most SPARC SBUS-based computers and
  1541. supports the Emulex family of ESP SCSI chips (esp100, esp100A,
  1542. esp236, fas101, fas236) as well as the Qlogic fas366 SCSI chip.
  1543. To compile this driver as a module, choose M here: the
  1544. module will be called sun_esp.
  1545. config ZFCP
  1546. tristate "FCP host bus adapter driver for IBM eServer zSeries"
  1547. depends on S390 && QDIO && SCSI
  1548. select SCSI_FC_ATTRS
  1549. help
  1550. If you want to access SCSI devices attached to your IBM eServer
  1551. zSeries by means of Fibre Channel interfaces say Y.
  1552. For details please refer to the documentation provided by IBM at
  1553. <http://oss.software.ibm.com/developerworks/opensource/linux390>
  1554. This driver is also available as a module. This module will be
  1555. called zfcp. If you want to compile it as a module, say M here
  1556. and read <file:Documentation/kbuild/modules.txt>.
  1557. config SCSI_PMCRAID
  1558. tristate "PMC SIERRA Linux MaxRAID adapter support"
  1559. depends on PCI && SCSI
  1560. ---help---
  1561. This driver supports the PMC SIERRA MaxRAID adapters.
  1562. config SCSI_PM8001
  1563. tristate "PMC-Sierra SPC 8001 SAS/SATA Based Host Adapter driver"
  1564. depends on PCI && SCSI
  1565. select SCSI_SAS_LIBSAS
  1566. help
  1567. This driver supports PMC-Sierra PCIE SAS/SATA 8x6G SPC 8001 chip
  1568. based host adapters.
  1569. config SCSI_SRP
  1570. tristate "SCSI RDMA Protocol helper library"
  1571. depends on SCSI && PCI
  1572. select SCSI_TGT
  1573. help
  1574. If you wish to use SRP target drivers, say Y.
  1575. To compile this driver as a module, choose M here: the
  1576. module will be called libsrp.
  1577. config SCSI_BFA_FC
  1578. tristate "Brocade BFA Fibre Channel Support"
  1579. depends on PCI && SCSI
  1580. select SCSI_FC_ATTRS
  1581. help
  1582. This bfa driver supports all Brocade PCIe FC/FCOE host adapters.
  1583. To compile this driver as a module, choose M here. The module will
  1584. be called bfa.
  1585. endif # SCSI_LOWLEVEL
  1586. source "drivers/scsi/pcmcia/Kconfig"
  1587. source "drivers/scsi/device_handler/Kconfig"
  1588. source "drivers/scsi/osd/Kconfig"
  1589. endmenu