浏览代码

[ALSA] ymfpci: fix SPDIF sample rate information

Modules: YMFPCI driver

Set the (read only) sample rate field in the IEC958 mixer controls to
48 kHz (instead of 44.1 kHz) because that is the rate actually
supported by the hardware.

Signed-off-by: Clemens Ladisch <clemens@ladisch.de>
Clemens Ladisch 19 年之前
父节点
当前提交
fc80a2027a
共有 1 个文件被更改,包括 2 次插入0 次删除
  1. 2 0
      sound/pci/ymfpci/ymfpci_main.c

+ 2 - 0
sound/pci/ymfpci/ymfpci_main.c

@@ -1229,6 +1229,7 @@ static int snd_ymfpci_spdif_default_get(struct snd_kcontrol *kcontrol,
 	spin_lock_irq(&chip->reg_lock);
 	ucontrol->value.iec958.status[0] = (chip->spdif_bits >> 0) & 0xff;
 	ucontrol->value.iec958.status[1] = (chip->spdif_bits >> 8) & 0xff;
+	ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
 	spin_unlock_irq(&chip->reg_lock);
 	return 0;
 }
@@ -1303,6 +1304,7 @@ static int snd_ymfpci_spdif_stream_get(struct snd_kcontrol *kcontrol,
 	spin_lock_irq(&chip->reg_lock);
 	ucontrol->value.iec958.status[0] = (chip->spdif_pcm_bits >> 0) & 0xff;
 	ucontrol->value.iec958.status[1] = (chip->spdif_pcm_bits >> 8) & 0xff;
+	ucontrol->value.iec958.status[3] = IEC958_AES3_CON_FS_48000;
 	spin_unlock_irq(&chip->reg_lock);
 	return 0;
 }