浏览代码

[SCSI] zfcp: Simplify ccw notify handler

The notify handler does not change the list of adapters, it only
triggers erp actions to open or shutdown the adapter. We don't
need to hold the config semaphore and wait for the erp to complete.

This is a prerequisite for a fix in the s390 common i/o code.

Signed-off-by: Christof Schmitt <christof.schmitt@de.ibm.com>
Signed-off-by: Martin Petermann <martin@linux.vnet.ibm.com>
Signed-off-by: James Bottomley <James.Bottomley@HansenPartnership.com>
Christof Schmitt 17 年之前
父节点
当前提交
f48bf7fb00
共有 1 个文件被更改,包括 1 次插入5 次删除
  1. 1 5
      drivers/s390/scsi/zfcp_ccw.c

+ 1 - 5
drivers/s390/scsi/zfcp_ccw.c

@@ -152,10 +152,8 @@ static int zfcp_ccw_set_offline(struct ccw_device *ccw_device)
  */
 static int zfcp_ccw_notify(struct ccw_device *ccw_device, int event)
 {
-	struct zfcp_adapter *adapter;
+	struct zfcp_adapter *adapter = dev_get_drvdata(&ccw_device->dev);
 
-	down(&zfcp_data.config_sema);
-	adapter = dev_get_drvdata(&ccw_device->dev);
 	switch (event) {
 	case CIO_GONE:
 		dev_warn(&adapter->ccw_device->dev, "device gone\n");
@@ -174,8 +172,6 @@ static int zfcp_ccw_notify(struct ccw_device *ccw_device, int event)
 					89, NULL);
 		break;
 	}
-	zfcp_erp_wait(adapter);
-	up(&zfcp_data.config_sema);
 	return 1;
 }