Browse Source

tg3: Remove unnecessary phy reset during ethtool commands

The current code unnecessarily resets the phy when we use ethtool to
change the ring parameters or flow control settings. Remove the phy
reset.

Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Nithin Sujir 12 years ago
parent
commit
f1315d2052
1 changed files with 2 additions and 2 deletions
  1. 2 2
      drivers/net/ethernet/broadcom/tg3.c

+ 2 - 2
drivers/net/ethernet/broadcom/tg3.c

@@ -11720,7 +11720,7 @@ static int tg3_set_ringparam(struct net_device *dev, struct ethtool_ringparam *e
 
 	if (netif_running(dev)) {
 		tg3_halt(tp, RESET_KIND_SHUTDOWN, 1);
-		err = tg3_restart_hw(tp, 1);
+		err = tg3_restart_hw(tp, 0);
 		if (!err)
 			tg3_netif_start(tp);
 	}
@@ -11841,7 +11841,7 @@ static int tg3_set_pauseparam(struct net_device *dev, struct ethtool_pauseparam
 
 		if (netif_running(dev)) {
 			tg3_halt(tp, RESET_KIND_SHUTDOWN, 1);
-			err = tg3_restart_hw(tp, 1);
+			err = tg3_restart_hw(tp, 0);
 			if (!err)
 				tg3_netif_start(tp);
 		}