tg3: Fix flow control settings not propagated to hardware

In tg3_setup_copper_phy(), if autonegotiation is disabled, we need to
relink only if the speed or duplex does not match the configured
setting.  If flow control does not match, a relink is not necessary as
flow control is not a PHY setting.  Later on, we'll call
tg3_setup_flow_ctrl() to set up the MAC to the desired flow control
settings if we're in full duplex mode.

Signed-off-by: Nithin Nayak Sujir <nsujir@broadcom.com>
Signed-off-by: Michael Chan <mchan@broadcom.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Nithin Sujir 12 years ago
parent
commit
f0fcd7a967
1 changed files with 1 additions and 3 deletions
  1. 1 3
      drivers/net/ethernet/broadcom/tg3.c

+ 1 - 3
drivers/net/ethernet/broadcom/tg3.c

@@ -4587,9 +4587,7 @@ static int tg3_setup_copper_phy(struct tg3 *tp, int force_reset)
 		} else {
 			if (!(bmcr & BMCR_ANENABLE) &&
 			    tp->link_config.speed == current_speed &&
-			    tp->link_config.duplex == current_duplex &&
-			    tp->link_config.flowctrl ==
-			    tp->link_config.active_flowctrl) {
+			    tp->link_config.duplex == current_duplex) {
 				current_link_up = 1;
 			}
 		}