浏览代码

itimer: Fix the itimer trace print format

Compiling powerpc64 results in:

include/trace/events/timer.h:279: warning:
format '%lu' expects type 'long unsigned int', but argument 4 has type 'cputime_t'
....

cputime_t on power is u64, which triggers the above warning.

Cast the cputime_t to unsigned long long and fix the print format
string. That works on both 32 and 64 bit architectures.

While at it change the print format for long variables from %lu to %ld.

Signed-off-by: Thomas Gleixner <tglx@linutronix.de>
Cc: Xiao Guangrong <xiaoguangrong@cn.fujitsu.com>
Thomas Gleixner 15 年之前
父节点
当前提交
e9c0748b68
共有 1 个文件被更改,包括 4 次插入4 次删除
  1. 4 4
      include/trace/events/timer.h

+ 4 - 4
include/trace/events/timer.h

@@ -301,8 +301,8 @@ TRACE_EVENT(itimer_state,
 		__entry->interval_usec	= value->it_interval.tv_usec;
 	),
 
-	TP_printk("which=%d expires=%lu it_value=%lu.%lu it_interval=%lu.%lu",
-		  __entry->which, __entry->expires,
+	TP_printk("which=%d expires=%llu it_value=%ld.%ld it_interval=%ld.%ld",
+		  __entry->which, (unsigned long long)__entry->expires,
 		  __entry->value_sec, __entry->value_usec,
 		  __entry->interval_sec, __entry->interval_usec)
 );
@@ -331,8 +331,8 @@ TRACE_EVENT(itimer_expire,
 		__entry->pid	= pid_nr(pid);
 	),
 
-	    TP_printk("which=%d pid=%d now=%lu", __entry->which,
-		      (int) __entry->pid, __entry->now)
+	TP_printk("which=%d pid=%d now=%llu", __entry->which,
+		  (int) __entry->pid, (unsigned long long)__entry->now)
 );
 
 #endif /*  _TRACE_TIMER_H */