SPI dynamic busid generation bugfix

Fix SPI dynamic bus ID assignment to start at 2^15-1 rather than a negative
number.  Valid bus ids are supposed to be positive, and are (now) stored in
an 's16' value.

Signed-off-by: David Brownell <dbrownell@users.sourceforge.net>
Signed-off-by: Andrew Morton <akpm@linux-foundation.org>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
David Brownell 18 gadi atpakaļ
vecāks
revīzija
e44a45ae7b
1 mainītis faili ar 1 papildinājumiem un 1 dzēšanām
  1. 1 1
      drivers/spi/spi.c

+ 1 - 1
drivers/spi/spi.c

@@ -411,7 +411,7 @@ EXPORT_SYMBOL_GPL(spi_alloc_master);
  */
 int spi_register_master(struct spi_master *master)
 {
-	static atomic_t		dyn_bus_id = ATOMIC_INIT((1<<16) - 1);
+	static atomic_t		dyn_bus_id = ATOMIC_INIT((1<<15) - 1);
 	struct device		*dev = master->cdev.dev;
 	int			status = -ENODEV;