@@ -45,6 +45,17 @@
|
|
|
#include <asm/ppc-pci.h>
|
|
|
#include <asm/rtas.h>
|
|
|
|
|
|
+/* RTAS tokens */
|
|
|
+static int ibm_set_eeh_option;
|
|
|
+static int ibm_set_slot_reset;
|
|
|
+static int ibm_read_slot_reset_state;
|
|
|
+static int ibm_read_slot_reset_state2;
|
|
|
+static int ibm_slot_error_detail;
|
|
|
+static int ibm_get_config_addr_info;
|
|
|
+static int ibm_get_config_addr_info2;
|
|
|
+static int ibm_configure_bridge;
|
|
|
+static int ibm_configure_pe;
|
|
|
+
|
|
|
/**
|
|
|
* pseries_eeh_init - EEH platform dependent initialization
|
|
|
*
|
|
@@ -52,6 +63,50 @@
|
|
|
*/
|
|
|
static int pseries_eeh_init(void)
|
|
|
{
|
|
|
+ /* figure out EEH RTAS function call tokens */
|
|
|
+ ibm_set_eeh_option = rtas_token("ibm,set-eeh-option");
|
|
|
+ ibm_set_slot_reset = rtas_token("ibm,set-slot-reset");
|
|
|
+ ibm_read_slot_reset_state2 = rtas_token("ibm,read-slot-reset-state2");
|
|
|
+ ibm_read_slot_reset_state = rtas_token("ibm,read-slot-reset-state");
|
|
|
+ ibm_slot_error_detail = rtas_token("ibm,slot-error-detail");
|
|
|
+ ibm_get_config_addr_info2 = rtas_token("ibm,get-config-addr-info2");
|
|
|
+ ibm_get_config_addr_info = rtas_token("ibm,get-config-addr-info");
|
|
|
+ ibm_configure_pe = rtas_token("ibm,configure-pe");
|
|
|
+ ibm_configure_bridge = rtas_token ("ibm,configure-bridge");
|
|
|
+
|
|
|
+ /* necessary sanity check */
|
|
|
+ if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm,set-eeh-option> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ } else if (ibm_set_slot_reset == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm, set-slot-reset> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ } else if (ibm_read_slot_reset_state2 == RTAS_UNKNOWN_SERVICE &&
|
|
|
+ ibm_read_slot_reset_state == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm,read-slot-reset-state2> and "
|
|
|
+ "<ibm,read-slot-reset-state> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ } else if (ibm_slot_error_detail == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm,slot-error-detail> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ } else if (ibm_get_config_addr_info2 == RTAS_UNKNOWN_SERVICE &&
|
|
|
+ ibm_get_config_addr_info == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm,get-config-addr-info2> and "
|
|
|
+ "<ibm,get-config-addr-info> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ } else if (ibm_configure_pe == RTAS_UNKNOWN_SERVICE &&
|
|
|
+ ibm_configure_bridge == RTAS_UNKNOWN_SERVICE) {
|
|
|
+ pr_warning("%s: RTAS service <ibm,configure-pe> and "
|
|
|
+ "<ibm,configure-bridge> invalid\n",
|
|
|
+ __func__);
|
|
|
+ return -EINVAL;
|
|
|
+ }
|
|
|
+
|
|
|
return 0;
|
|
|
}
|
|
|
|