@@ -201,13 +201,7 @@ static unsigned int palmas_smps_ramp_delay[4] = {0, 10000, 5000, 2500};
|
|
|
#define SMPS_CTRL_MODE_ECO 0x02
|
|
|
#define SMPS_CTRL_MODE_PWM 0x03
|
|
|
|
|
|
-/* These values are derived from the data sheet. And are the number of steps
|
|
|
- * where there is a voltage change, the ranges at beginning and end of register
|
|
|
- * max/min values where there are no change are ommitted.
|
|
|
- *
|
|
|
- * So they are basically (maxV-minV)/stepV
|
|
|
- */
|
|
|
-#define PALMAS_SMPS_NUM_VOLTAGES 117
|
|
|
+#define PALMAS_SMPS_NUM_VOLTAGES 122
|
|
|
#define PALMAS_SMPS10_NUM_VOLTAGES 2
|
|
|
#define PALMAS_LDO_NUM_VOLTAGES 50
|
|
|
|
|
@@ -979,6 +973,7 @@ static int palmas_regulators_probe(struct platform_device *pdev)
|
|
|
pmic->desc[id].min_uV = 900000;
|
|
|
pmic->desc[id].uV_step = 50000;
|
|
|
pmic->desc[id].linear_min_sel = 1;
|
|
|
+ pmic->desc[id].enable_time = 500;
|
|
|
pmic->desc[id].vsel_reg =
|
|
|
PALMAS_BASE_TO_REG(PALMAS_LDO_BASE,
|
|
|
palmas_regs_info[id].vsel_addr);
|
|
@@ -997,6 +992,11 @@ static int palmas_regulators_probe(struct platform_device *pdev)
|
|
|
pmic->desc[id].min_uV = 450000;
|
|
|
pmic->desc[id].uV_step = 25000;
|
|
|
}
|
|
|
+
|
|
|
+ /* LOD6 in vibrator mode will have enable time 2000us */
|
|
|
+ if (pdata && pdata->ldo6_vibrator &&
|
|
|
+ (id == PALMAS_REG_LDO6))
|
|
|
+ pmic->desc[id].enable_time = 2000;
|
|
|
} else {
|
|
|
pmic->desc[id].n_voltages = 1;
|
|
|
pmic->desc[id].ops = &palmas_ops_extreg;
|