Jelajahi Sumber

Bluetooth: Remove page timeout setting from HCI init sequence

User space should set the page timeout so there's no need to explicitly
set it in the HCI init sequence. Even if user space fails to set it the
controller default value will be used.

Signed-off-by: Johan Hedberg <johan.hedberg@nokia.com>
Signed-off-by: Gustavo F. Padovan <padovan@profusion.mobi>
Johan Hedberg 14 tahun lalu
induk
melakukan
d835060036
1 mengubah file dengan 0 tambahan dan 4 penghapusan
  1. 0 4
      net/bluetooth/hci_core.c

+ 0 - 4
net/bluetooth/hci_core.c

@@ -254,10 +254,6 @@ static void hci_init_req(struct hci_dev *hdev, unsigned long opt)
 	flt_type = HCI_FLT_CLEAR_ALL;
 	flt_type = HCI_FLT_CLEAR_ALL;
 	hci_send_cmd(hdev, HCI_OP_SET_EVENT_FLT, 1, &flt_type);
 	hci_send_cmd(hdev, HCI_OP_SET_EVENT_FLT, 1, &flt_type);
 
 
-	/* Page timeout ~20 secs */
-	param = cpu_to_le16(0x8000);
-	hci_send_cmd(hdev, HCI_OP_WRITE_PG_TIMEOUT, 2, &param);
-
 	/* Connection accept timeout ~20 secs */
 	/* Connection accept timeout ~20 secs */
 	param = cpu_to_le16(0x7d00);
 	param = cpu_to_le16(0x7d00);
 	hci_send_cmd(hdev, HCI_OP_WRITE_CA_TIMEOUT, 2, &param);
 	hci_send_cmd(hdev, HCI_OP_WRITE_CA_TIMEOUT, 2, &param);