@@ -18,8 +18,8 @@
|
|
|
</affiliation>
|
|
|
</author>
|
|
|
|
|
|
- <date>July 26, 2007</date>
|
|
|
- <edition>0.3.6.1</edition>
|
|
|
+ <date>September 10, 2007</date>
|
|
|
+ <edition>0.3.7</edition>
|
|
|
|
|
|
<abstract>
|
|
|
<para>
|
|
@@ -3472,6 +3472,13 @@ struct _snd_pcm_runtime {
|
|
|
(casted to unsigned long) of some record to this field, too.
|
|
|
</para>
|
|
|
|
|
|
+ <para>
|
|
|
+ The <structfield>tlv</structfield> field can be used to provide
|
|
|
+ metadata about the control; see the
|
|
|
+ <link linkend="control-interface-tlv">
|
|
|
+ <citetitle>Metadata</citetitle></link> subsection.
|
|
|
+ </para>
|
|
|
+
|
|
|
<para>
|
|
|
The other three are
|
|
|
<link linkend="control-interface-callbacks"><citetitle>
|
|
@@ -3871,6 +3878,56 @@ struct _snd_pcm_runtime {
|
|
|
</para>
|
|
|
</section>
|
|
|
|
|
|
+ <section id="control-interface-tlv">
|
|
|
+ <title>Metadata</title>
|
|
|
+ <para>
|
|
|
+ To provide information about the dB values of a mixer control, use
|
|
|
+ on of the <constant>DECLARE_TLV_xxx</constant> macros from
|
|
|
+ <filename><sound/tlv.h></filename> to define a variable
|
|
|
+ containing this information, set the<structfield>tlv.p
|
|
|
+ </structfield> field to point to this variable, and include the
|
|
|
+ <constant>SNDRV_CTL_ELEM_ACCESS_TLV_READ</constant> flag in the
|
|
|
+ <structfield>access</structfield> field; like this:
|
|
|
+ <informalexample>
|
|
|
+ <programlisting>
|
|
|
+<![CDATA[
|
|
|
+ static DECLARE_TLV_DB_SCALE(db_scale_my_control, -4050, 150, 0);
|
|
|
+
|
|
|
+ static struct snd_kcontrol_new my_control __devinitdata = {
|
|
|
+ ...
|
|
|
+ .access = SNDRV_CTL_ELEM_ACCESS_READWRITE |
|
|
|
+ SNDRV_CTL_ELEM_ACCESS_TLV_READ,
|
|
|
+ ...
|
|
|
+ .tlv.p = db_scale_my_control,
|
|
|
+ };
|
|
|
+]]>
|
|
|
+ </programlisting>
|
|
|
+ </informalexample>
|
|
|
+ </para>
|
|
|
+
|
|
|
+ <para>
|
|
|
+ The <function>DECLARE_TLV_DB_SCALE</function> macro defines
|
|
|
+ information about a mixer control where each step in the control's
|
|
|
+ value changes the dB value by a constant dB amount.
|
|
|
+ The first parameter is the name of the variable to be defined.
|
|
|
+ The second parameter is the minimum value, in units of 0.01 dB.
|
|
|
+ The third parameter is the step size, in units of 0.01 dB.
|
|
|
+ Set the fourth parameter to 1 if the minimum value actually mutes
|
|
|
+ the control.
|
|
|
+ </para>
|
|
|
+
|
|
|
+ <para>
|
|
|
+ The <function>DECLARE_TLV_DB_LINEAR</function> macro defines
|
|
|
+ information about a mixer control where the control's value affects
|
|
|
+ the output linearly.
|
|
|
+ The first parameter is the name of the variable to be defined.
|
|
|
+ The second parameter is the minimum value, in units of 0.01 dB.
|
|
|
+ The third parameter is the maximum value, in units of 0.01 dB.
|
|
|
+ If the minimum value mutes the control, set the second parameter to
|
|
|
+ <constant>TLV_DB_GAIN_MUTE</constant>.
|
|
|
+ </para>
|
|
|
+ </section>
|
|
|
+
|
|
|
</chapter>
|
|
|
|
|
|
|