Browse Source

isci: Change the phy control and link reset interface for HW reasons.

There is an apparent HW lockup caused when the PE is disabled while there
is an outstanding TC in progress.  This change puts the link into OOB to
force the TC to end before the PE is disabled.

Signed-off-by: Jeff Skirvin <jeffrey.d.skirvin@intel.com>
Signed-off-by: Dan Williams <dan.j.williams@intel.com>
Jeff Skirvin 13 years ago
parent
commit
c5457a82a4
1 changed files with 2 additions and 0 deletions
  1. 2 0
      drivers/scsi/isci/phy.c

+ 2 - 0
drivers/scsi/isci/phy.c

@@ -1442,12 +1442,14 @@ int isci_phy_control(struct asd_sas_phy *sas_phy,
 	switch (func) {
 	case PHY_FUNC_DISABLE:
 		spin_lock_irqsave(&ihost->scic_lock, flags);
+		scu_link_layer_start_oob(iphy);
 		sci_phy_stop(iphy);
 		spin_unlock_irqrestore(&ihost->scic_lock, flags);
 		break;
 
 	case PHY_FUNC_LINK_RESET:
 		spin_lock_irqsave(&ihost->scic_lock, flags);
+		scu_link_layer_start_oob(iphy);
 		sci_phy_stop(iphy);
 		sci_phy_start(iphy);
 		spin_unlock_irqrestore(&ihost->scic_lock, flags);