Переглянути джерело

Input: synaptics - fix wrong dimensions check

The commit 83ba9ea8a04b72dfee2515428c15e7414ba4fc61 ommitted the return
line for the old synaptics model accidentally.  This resulted in a wrong
check, namely, the dimensions are checked for the old devices that don't
support the query properly.

This patch adds the return line back.

Signed-off-by: Takashi Iwai <tiwai@suse.de>
Signed-off-by: Dmitry Torokhov <dtor@mail.ru>
Takashi Iwai 15 роки тому
батько
коміт
bbddd19999
1 змінених файлів з 1 додано та 0 видалено
  1. 1 0
      drivers/input/mouse/synaptics.c

+ 1 - 0
drivers/input/mouse/synaptics.c

@@ -206,6 +206,7 @@ static int synaptics_resolution(struct psmouse *psmouse)
 	unsigned char max[3];
 
 	if (SYN_ID_MAJOR(priv->identity) < 4)
+		return 0;
 
 	if (synaptics_send_cmd(psmouse, SYN_QUE_RESOLUTION, res) == 0) {
 		if (res[0] != 0 && (res[1] & 0x80) && res[2] != 0) {