Browse Source

ARM: LPC32xx: Remove SLC controller initialization from platform init

Since we now support two MTD NAND controllers (MLC and SLC) for LPC32xx via DT,
we don't initialize the SLC controller statically anymore, but do it via the
clock setup (see previous patch).

Signed-off-by: Roland Stigge <stigge@antcom.de>
Tested-by: Alexandre Pereira da Silva <aletes.xgr@gmail.com>
Roland Stigge 13 years ago
parent
commit
ba225a0ea2
1 changed files with 0 additions and 4 deletions
  1. 0 4
      arch/arm/mach-lpc32xx/phy3250.c

+ 0 - 4
arch/arm/mach-lpc32xx/phy3250.c

@@ -241,10 +241,6 @@ static void __init lpc3250_machine_init(void)
 {
 	u32 tmp;
 
-	/* Setup SLC NAND controller muxing */
-	__raw_writel(LPC32XX_CLKPWR_NANDCLK_SEL_SLC,
-		LPC32XX_CLKPWR_NAND_CLK_CTRL);
-
 	/* Setup LCD muxing to RGB565 */
 	tmp = __raw_readl(LPC32XX_CLKPWR_LCDCLK_CTRL) &
 		~(LPC32XX_CLKPWR_LCDCTRL_LCDTYPE_MSK |