@@ -304,39 +304,6 @@ static int ab3100_get_voltage_regulator(struct regulator_dev *reg)
|
|
|
return abreg->typ_voltages[regval];
|
|
|
}
|
|
|
|
|
|
-static int ab3100_get_best_voltage_index(struct regulator_dev *reg,
|
|
|
- int min_uV, int max_uV)
|
|
|
-{
|
|
|
- struct ab3100_regulator *abreg = reg->reg_data;
|
|
|
- int i;
|
|
|
- int bestmatch;
|
|
|
- int bestindex;
|
|
|
-
|
|
|
- /*
|
|
|
- * Locate the minimum voltage fitting the criteria on
|
|
|
- * this regulator. The switchable voltages are not
|
|
|
- * in strict falling order so we need to check them
|
|
|
- * all for the best match.
|
|
|
- */
|
|
|
- bestmatch = INT_MAX;
|
|
|
- bestindex = -1;
|
|
|
- for (i = 0; i < abreg->voltages_len; i++) {
|
|
|
- if (abreg->typ_voltages[i] <= max_uV &&
|
|
|
- abreg->typ_voltages[i] >= min_uV &&
|
|
|
- abreg->typ_voltages[i] < bestmatch) {
|
|
|
- bestmatch = abreg->typ_voltages[i];
|
|
|
- bestindex = i;
|
|
|
- }
|
|
|
- }
|
|
|
-
|
|
|
- if (bestindex < 0) {
|
|
|
- dev_warn(®->dev, "requested %d<=x<=%d uV, out of range!\n",
|
|
|
- min_uV, max_uV);
|
|
|
- return -EINVAL;
|
|
|
- }
|
|
|
- return bestindex;
|
|
|
-}
|
|
|
-
|
|
|
static int ab3100_set_voltage_regulator_sel(struct regulator_dev *reg,
|
|
|
unsigned selector)
|
|
|
{
|
|
@@ -383,7 +350,7 @@ static int ab3100_set_suspend_voltage_regulator(struct regulator_dev *reg,
|
|
|
return -EINVAL;
|
|
|
|
|
|
/* LDO E and BUCK have special suspend voltages you can set */
|
|
|
- bestindex = ab3100_get_best_voltage_index(reg, uV, uV);
|
|
|
+ bestindex = regulator_map_voltage_iterate(reg, uV, uV);
|
|
|
|
|
|
err = abx500_get_register_interruptible(abreg->dev, 0,
|
|
|
targetreg, ®val);
|