@@ -121,6 +121,32 @@ static bool is_ext_pwr_online(struct charger_manager *cm)
|
|
return online;
|
|
return online;
|
|
}
|
|
}
|
|
|
|
|
|
|
|
+/**
|
|
|
|
+ * get_batt_uV - Get the voltage level of the battery
|
|
|
|
+ * @cm: the Charger Manager representing the battery.
|
|
|
|
+ * @uV: the voltage level returned.
|
|
|
|
+ *
|
|
|
|
+ * Returns 0 if there is no error.
|
|
|
|
+ * Returns a negative value on error.
|
|
|
|
+ */
|
|
|
|
+static int get_batt_uV(struct charger_manager *cm, int *uV)
|
|
|
|
+{
|
|
|
|
+ union power_supply_propval val;
|
|
|
|
+ int ret;
|
|
|
|
+
|
|
|
|
+ if (cm->fuel_gauge)
|
|
|
|
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
|
|
|
|
+ else
|
|
|
|
+ return -ENODEV;
|
|
|
|
+
|
|
|
|
+ if (ret)
|
|
|
|
+ return ret;
|
|
|
|
+
|
|
|
|
+ *uV = val.intval;
|
|
|
|
+ return 0;
|
|
|
|
+}
|
|
|
|
+
|
|
/**
|
|
/**
|
|
* is_charging - Returns true if the battery is being charged.
|
|
* is_charging - Returns true if the battery is being charged.
|
|
* @cm: the Charger Manager representing the battery.
|
|
* @cm: the Charger Manager representing the battery.
|
|
@@ -369,6 +395,208 @@ static bool cm_monitor(void)
|
|
return stop;
|
|
return stop;
|
|
}
|
|
}
|
|
|
|
|
|
|
|
+static int charger_get_property(struct power_supply *psy,
|
|
|
|
+ enum power_supply_property psp,
|
|
|
|
+ union power_supply_propval *val)
|
|
|
|
+{
|
|
|
|
+ struct charger_manager *cm = container_of(psy,
|
|
|
|
+ struct charger_manager, charger_psy);
|
|
|
|
+ struct charger_desc *desc = cm->desc;
|
|
|
|
+ int i, ret = 0, uV;
|
|
|
|
+
|
|
|
|
+ switch (psp) {
|
|
|
|
+ case POWER_SUPPLY_PROP_STATUS:
|
|
|
|
+ if (is_charging(cm))
|
|
|
|
+ val->intval = POWER_SUPPLY_STATUS_CHARGING;
|
|
|
|
+ else if (is_ext_pwr_online(cm))
|
|
|
|
+ val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
|
|
|
|
+ else
|
|
|
|
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_HEALTH:
|
|
|
|
+ if (cm->emergency_stop > 0)
|
|
|
|
+ val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
|
|
|
|
+ else if (cm->emergency_stop < 0)
|
|
|
|
+ val->intval = POWER_SUPPLY_HEALTH_COLD;
|
|
|
|
+ else
|
|
|
|
+ val->intval = POWER_SUPPLY_HEALTH_GOOD;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_PRESENT:
|
|
|
|
+ if (is_batt_present(cm))
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ else
|
|
|
|
+ val->intval = 0;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
|
|
|
+ ret = get_batt_uV(cm, &i);
|
|
|
|
+ val->intval = i;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_CURRENT_NOW:
|
|
|
|
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CURRENT_NOW, val);
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_TEMP:
|
|
|
|
+ /* in thenth of centigrade */
|
|
|
|
+ if (cm->last_temp_mC == INT_MIN)
|
|
|
|
+ desc->temperature_out_of_range(&cm->last_temp_mC);
|
|
|
|
+ val->intval = cm->last_temp_mC / 100;
|
|
|
|
+ if (!desc->measure_battery_temp)
|
|
|
|
+ ret = -ENODEV;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_TEMP_AMBIENT:
|
|
|
|
+ /* in thenth of centigrade */
|
|
|
|
+ if (cm->last_temp_mC == INT_MIN)
|
|
|
|
+ desc->temperature_out_of_range(&cm->last_temp_mC);
|
|
|
|
+ val->intval = cm->last_temp_mC / 100;
|
|
|
|
+ if (desc->measure_battery_temp)
|
|
|
|
+ ret = -ENODEV;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_CAPACITY:
|
|
|
|
+ if (!cm->fuel_gauge) {
|
|
|
|
+ ret = -ENODEV;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ if (!is_batt_present(cm)) {
|
|
|
|
+ /* There is no battery. Assume 100% */
|
|
|
|
+ val->intval = 100;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CAPACITY, val);
|
|
|
|
+ if (ret)
|
|
|
|
+ break;
|
|
|
|
+
|
|
|
|
+ if (val->intval > 100) {
|
|
|
|
+ val->intval = 100;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+ if (val->intval < 0)
|
|
|
|
+ val->intval = 0;
|
|
|
|
+
|
|
|
|
+ /* Do not adjust SOC when charging: voltage is overrated */
|
|
|
|
+ if (is_charging(cm))
|
|
|
|
+ break;
|
|
|
|
+
|
|
|
|
+ /*
|
|
|
|
+ * If the capacity value is inconsistent, calibrate it base on
|
|
|
|
+ * the battery voltage values and the thresholds given as desc
|
|
|
|
+ */
|
|
|
|
+ ret = get_batt_uV(cm, &uV);
|
|
|
|
+ if (ret) {
|
|
|
|
+ /* Voltage information not available. No calibration */
|
|
|
|
+ ret = 0;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
|
|
|
|
+ !is_charging(cm)) {
|
|
|
|
+ val->intval = 100;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_ONLINE:
|
|
|
|
+ if (is_ext_pwr_online(cm))
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ else
|
|
|
|
+ val->intval = 0;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_CHARGE_FULL:
|
|
|
|
+ if (cm->fuel_gauge) {
|
|
|
|
+ if (cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0)
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ if (is_ext_pwr_online(cm)) {
|
|
|
|
+ /* Not full if it's charging. */
|
|
|
|
+ if (is_charging(cm)) {
|
|
|
|
+ val->intval = 0;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+ /*
|
|
|
|
+ * Full if it's powered but not charging andi
|
|
|
|
+ * not forced stop by emergency
|
|
|
|
+ */
|
|
|
|
+ if (!cm->emergency_stop) {
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ /* Full if it's over the fullbatt voltage */
|
|
|
|
+ ret = get_batt_uV(cm, &uV);
|
|
|
|
+ if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
|
|
|
|
+ !is_charging(cm)) {
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ /* Full if the cap is 100 */
|
|
|
|
+ if (cm->fuel_gauge) {
|
|
|
|
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CAPACITY, val);
|
|
|
|
+ if (!ret && val->intval >= 100 && !is_charging(cm)) {
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ break;
|
|
|
|
+ }
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ val->intval = 0;
|
|
|
|
+ ret = 0;
|
|
|
|
+ break;
|
|
|
|
+ case POWER_SUPPLY_PROP_CHARGE_NOW:
|
|
|
|
+ if (is_charging(cm)) {
|
|
|
|
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CHARGE_NOW,
|
|
|
|
+ val);
|
|
|
|
+ if (ret) {
|
|
|
|
+ val->intval = 1;
|
|
|
|
+ ret = 0;
|
|
|
|
+ } else {
|
|
|
|
+ /* If CHARGE_NOW is supplied, use it */
|
|
|
|
+ val->intval = (val->intval > 0) ?
|
|
|
|
+ val->intval : 1;
|
|
|
|
+ }
|
|
|
|
+ } else {
|
|
|
|
+ val->intval = 0;
|
|
|
|
+ }
|
|
|
|
+ break;
|
|
|
|
+ default:
|
|
|
|
+ return -EINVAL;
|
|
|
|
+ }
|
|
|
|
+ return ret;
|
|
|
|
+}
|
|
|
|
+
|
|
|
|
+#define NUM_CHARGER_PSY_OPTIONAL (4)
|
|
|
|
+static enum power_supply_property default_charger_props[] = {
|
|
|
|
+ /* Guaranteed to provide */
|
|
|
|
+ POWER_SUPPLY_PROP_STATUS,
|
|
|
|
+ POWER_SUPPLY_PROP_HEALTH,
|
|
|
|
+ POWER_SUPPLY_PROP_PRESENT,
|
|
|
|
+ POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
|
|
|
+ POWER_SUPPLY_PROP_CAPACITY,
|
|
|
|
+ POWER_SUPPLY_PROP_ONLINE,
|
|
|
|
+ POWER_SUPPLY_PROP_CHARGE_FULL,
|
|
|
|
+ /*
|
|
|
|
+ * Optional properties are:
|
|
|
|
+ * POWER_SUPPLY_PROP_CHARGE_NOW,
|
|
|
|
+ * POWER_SUPPLY_PROP_CURRENT_NOW,
|
|
|
|
+ * POWER_SUPPLY_PROP_TEMP, and
|
|
|
|
+ * POWER_SUPPLY_PROP_TEMP_AMBIENT,
|
|
|
|
+ */
|
|
|
|
+};
|
|
|
|
+
|
|
|
|
+static struct power_supply psy_default = {
|
|
|
|
+ .name = "battery",
|
|
|
|
+ .type = POWER_SUPPLY_TYPE_BATTERY,
|
|
|
|
+ .properties = default_charger_props,
|
|
|
|
+ .num_properties = ARRAY_SIZE(default_charger_props),
|
|
|
|
+ .get_property = charger_get_property,
|
|
|
|
+};
|
|
|
|
+
|
|
/**
|
|
/**
|
|
* cm_setup_timer - For in-suspend monitoring setup wakeup alarm
|
|
* cm_setup_timer - For in-suspend monitoring setup wakeup alarm
|
|
* for suspend_again.
|
|
* for suspend_again.
|
|
@@ -532,6 +760,7 @@ static int charger_manager_probe(struct platform_device *pdev)
|
|
struct charger_desc *desc = dev_get_platdata(&pdev->dev);
|
|
struct charger_desc *desc = dev_get_platdata(&pdev->dev);
|
|
struct charger_manager *cm;
|
|
struct charger_manager *cm;
|
|
int ret = 0, i = 0;
|
|
int ret = 0, i = 0;
|
|
|
|
+ union power_supply_propval val;
|
|
|
|
|
|
if (g_desc && !rtc_dev && g_desc->rtc_name) {
|
|
if (g_desc && !rtc_dev && g_desc->rtc_name) {
|
|
rtc_dev = rtc_class_open(g_desc->rtc_name);
|
|
rtc_dev = rtc_class_open(g_desc->rtc_name);
|
|
@@ -626,11 +855,68 @@ static int charger_manager_probe(struct platform_device *pdev)
|
|
|
|
|
|
platform_set_drvdata(pdev, cm);
|
|
platform_set_drvdata(pdev, cm);
|
|
|
|
|
|
|
|
+ memcpy(&cm->charger_psy, &psy_default,
|
|
|
|
+ sizeof(psy_default));
|
|
|
|
+ if (!desc->psy_name) {
|
|
|
|
+ strncpy(cm->psy_name_buf, psy_default.name,
|
|
|
|
+ PSY_NAME_MAX);
|
|
|
|
+ } else {
|
|
|
|
+ strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
|
|
|
|
+ }
|
|
|
|
+ cm->charger_psy.name = cm->psy_name_buf;
|
|
|
|
+
|
|
|
|
+ /* Allocate for psy properties because they may vary */
|
|
|
|
+ cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property)
|
|
|
|
+ * (ARRAY_SIZE(default_charger_props) +
|
|
|
|
+ NUM_CHARGER_PSY_OPTIONAL),
|
|
|
|
+ GFP_KERNEL);
|
|
|
|
+ if (!cm->charger_psy.properties) {
|
|
|
|
+ dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
|
|
|
|
+ ret = -ENOMEM;
|
|
|
|
+ goto err_chg_stat;
|
|
|
|
+ }
|
|
|
|
+ memcpy(cm->charger_psy.properties, default_charger_props,
|
|
|
|
+ sizeof(enum power_supply_property) *
|
|
|
|
+ ARRAY_SIZE(default_charger_props));
|
|
|
|
+ cm->charger_psy.num_properties = psy_default.num_properties;
|
|
|
|
+
|
|
|
|
+ /* Find which optional psy-properties are available */
|
|
|
|
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
|
|
|
|
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
|
|
|
|
+ POWER_SUPPLY_PROP_CHARGE_NOW;
|
|
|
|
+ cm->charger_psy.num_properties++;
|
|
|
|
+ }
|
|
|
|
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
|
|
|
|
+ POWER_SUPPLY_PROP_CURRENT_NOW,
|
|
|
|
+ &val)) {
|
|
|
|
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
|
|
|
|
+ POWER_SUPPLY_PROP_CURRENT_NOW;
|
|
|
|
+ cm->charger_psy.num_properties++;
|
|
|
|
+ }
|
|
|
|
+ if (!desc->measure_battery_temp) {
|
|
|
|
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
|
|
|
|
+ POWER_SUPPLY_PROP_TEMP_AMBIENT;
|
|
|
|
+ cm->charger_psy.num_properties++;
|
|
|
|
+ }
|
|
|
|
+ if (desc->measure_battery_temp) {
|
|
|
|
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
|
|
|
|
+ POWER_SUPPLY_PROP_TEMP;
|
|
|
|
+ cm->charger_psy.num_properties++;
|
|
|
|
+ }
|
|
|
|
+
|
|
|
|
+ ret = power_supply_register(NULL, &cm->charger_psy);
|
|
|
|
+ if (ret) {
|
|
|
|
+ dev_err(&pdev->dev, "Cannot register charger-manager with"
|
|
|
|
+ " name \"%s\".\n", cm->charger_psy.name);
|
|
|
|
+ goto err_register;
|
|
|
|
+ }
|
|
|
|
+
|
|
ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators,
|
|
ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators,
|
|
desc->charger_regulators);
|
|
desc->charger_regulators);
|
|
if (ret) {
|
|
if (ret) {
|
|
dev_err(&pdev->dev, "Cannot get charger regulators.\n");
|
|
dev_err(&pdev->dev, "Cannot get charger regulators.\n");
|
|
- goto err_chg_stat;
|
|
|
|
|
|
+ goto err_bulk_get;
|
|
}
|
|
}
|
|
|
|
|
|
ret = try_charger_enable(cm, true);
|
|
ret = try_charger_enable(cm, true);
|
|
@@ -650,6 +936,10 @@ err_chg_enable:
|
|
if (desc->charger_regulators)
|
|
if (desc->charger_regulators)
|
|
regulator_bulk_free(desc->num_charger_regulators,
|
|
regulator_bulk_free(desc->num_charger_regulators,
|
|
desc->charger_regulators);
|
|
desc->charger_regulators);
|
|
|
|
+err_bulk_get:
|
|
|
|
+ power_supply_unregister(&cm->charger_psy);
|
|
|
|
+err_register:
|
|
|
|
+ kfree(cm->charger_psy.properties);
|
|
err_chg_stat:
|
|
err_chg_stat:
|
|
kfree(cm->charger_stat);
|
|
kfree(cm->charger_stat);
|
|
err_no_charger_stat:
|
|
err_no_charger_stat:
|
|
@@ -674,6 +964,9 @@ static int __devexit charger_manager_remove(struct platform_device *pdev)
|
|
if (desc->charger_regulators)
|
|
if (desc->charger_regulators)
|
|
regulator_bulk_free(desc->num_charger_regulators,
|
|
regulator_bulk_free(desc->num_charger_regulators,
|
|
desc->charger_regulators);
|
|
desc->charger_regulators);
|
|
|
|
+
|
|
|
|
+ power_supply_unregister(&cm->charger_psy);
|
|
|
|
+ kfree(cm->charger_psy.properties);
|
|
kfree(cm->charger_stat);
|
|
kfree(cm->charger_stat);
|
|
kfree(cm->desc);
|
|
kfree(cm->desc);
|
|
kfree(cm);
|
|
kfree(cm);
|