瀏覽代碼

ACPI: Fix ACPI battery regression introduced by commit 558073

Commit 558073dd56707864f09d563b64e7c37c021e89d2 ("ACPI: battery: Convert
discharge energy rate to current properly") caused the battery subsystem
to report wrong values of the remaining time on battery power and the
time until fully charged on Toshiba Portege R500 (and presumably on
other boxes too).

Fix the issue by correcting the conversion from mW to mA.

Signed-off-by: Rafael J. Wysocki <rjw@sisk.pl>
Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
Rafael J. Wysocki 16 年之前
父節點
當前提交
aaad077638
共有 1 個文件被更改,包括 10 次插入7 次删除
  1. 10 7
      drivers/acpi/battery.c

+ 10 - 7
drivers/acpi/battery.c

@@ -173,14 +173,17 @@ static int acpi_battery_get_property(struct power_supply *psy,
 		val->intval = battery->voltage_now * 1000;
 		break;
 	case POWER_SUPPLY_PROP_CURRENT_NOW:
-		val->intval = battery->current_now * 1000;
-		/* if power units are mW, convert to mA by
-		   dividing by current voltage (mV/1000) */
-		if (!battery->power_unit) {
-			if (battery->voltage_now) {
+		val->intval = battery->current_now;
+		if (battery->power_unit) {
+			val->intval *= 1000;
+		} else {
+			/*
+			 * If power units are mW, convert to mA by dividing by
+			 * current voltage.
+			 */
+			if (battery->voltage_now)
 				val->intval /= battery->voltage_now;
-				val->intval *= 1000;
-			} else
+			else
 				val->intval = -1;
 		}
 		break;