Parcourir la source

[SCSI] mpt2sas: do not check serial_number in the abort handler

The SCSI midlayer stops all command processing when in error handling, which
means there is no chance for command reuse when the abort handler is called.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: "Moore, Eric" <Eric.Moore@lsi.com>
Signed-off-by: James Bottomley <James.Bottomley@suse.de>
Christoph Hellwig il y a 14 ans
Parent
commit
a7c44d4ad1
1 fichiers modifiés avec 1 ajouts et 2 suppressions
  1. 1 2
      drivers/scsi/mpt2sas/mpt2sas_scsih.c

+ 1 - 2
drivers/scsi/mpt2sas/mpt2sas_scsih.c

@@ -2133,8 +2133,7 @@ mpt2sas_scsih_issue_tm(struct MPT2SAS_ADAPTER *ioc, u16 handle, uint channel,
 	switch (type) {
 	case MPI2_SCSITASKMGMT_TASKTYPE_ABORT_TASK:
 		scmd_lookup = _scsih_scsi_lookup_get(ioc, smid_task);
-		if (scmd_lookup && (scmd_lookup->serial_number ==
-		    scmd->serial_number))
+		if (scmd_lookup)
 			rc = FAILED;
 		else
 			rc = SUCCESS;