@@ -1550,11 +1550,13 @@ __u32 secure_tcp_sequence_number(__be32 saddr, __be32 daddr,
|
|
|
* As close as possible to RFC 793, which
|
|
|
* suggests using a 250 kHz clock.
|
|
|
* Further reading shows this assumes 2 Mb/s networks.
|
|
|
- * For 10 Gb/s Ethernet, a 1 GHz clock is appropriate.
|
|
|
- * That's funny, Linux has one built in! Use it!
|
|
|
- * (Networks are faster now - should this be increased?)
|
|
|
+ * For 10 Mb/s Ethernet, a 1 MHz clock is appropriate.
|
|
|
+ * For 10 Gb/s Ethernet, a 1 GHz clock should be ok, but
|
|
|
+ * we also need to limit the resolution so that the u32 seq
|
|
|
+ * overlaps less than one time per MSL (2 minutes).
|
|
|
+ * Choosing a clock of 64 ns period is OK. (period of 274 s)
|
|
|
*/
|
|
|
- seq += ktime_get_real().tv64;
|
|
|
+ seq += ktime_get_real().tv64 >> 6;
|
|
|
#if 0
|
|
|
printk("init_seq(%lx, %lx, %d, %d) = %d\n",
|
|
|
saddr, daddr, sport, dport, seq);
|