@@ -233,7 +233,7 @@ static void iwl_tt_ready_for_ct_kill(unsigned long data)
|
|
|
IWL_DEBUG_TEMP(priv, "entering CT_KILL state when "
|
|
|
"temperature timer expired\n");
|
|
|
tt->state = IWL_TI_CT_KILL;
|
|
|
- set_bit(STATUS_CT_KILL, &priv->shrd->status);
|
|
|
+ set_bit(STATUS_CT_KILL, &priv->status);
|
|
|
iwl_perform_ct_kill_task(priv, true);
|
|
|
}
|
|
|
}
|
|
@@ -313,22 +313,21 @@ static void iwl_legacy_tt_handler(struct iwl_priv *priv, s32 temp, bool force)
|
|
|
}
|
|
|
mutex_lock(&priv->mutex);
|
|
|
if (old_state == IWL_TI_CT_KILL)
|
|
|
- clear_bit(STATUS_CT_KILL, &priv->shrd->status);
|
|
|
+ clear_bit(STATUS_CT_KILL, &priv->status);
|
|
|
if (tt->state != IWL_TI_CT_KILL &&
|
|
|
iwl_power_update_mode(priv, true)) {
|
|
|
/* TT state not updated
|
|
|
* try again during next temperature read
|
|
|
*/
|
|
|
if (old_state == IWL_TI_CT_KILL)
|
|
|
- set_bit(STATUS_CT_KILL, &priv->shrd->status);
|
|
|
+ set_bit(STATUS_CT_KILL, &priv->status);
|
|
|
tt->state = old_state;
|
|
|
IWL_ERR(priv, "Cannot update power mode, "
|
|
|
"TT state not updated\n");
|
|
|
} else {
|
|
|
if (tt->state == IWL_TI_CT_KILL) {
|
|
|
if (force) {
|
|
|
- set_bit(STATUS_CT_KILL,
|
|
|
- &priv->shrd->status);
|
|
|
+ set_bit(STATUS_CT_KILL, &priv->status);
|
|
|
iwl_perform_ct_kill_task(priv, true);
|
|
|
} else {
|
|
|
iwl_prepare_ct_kill_task(priv);
|
|
@@ -454,7 +453,7 @@ static void iwl_advance_tt_handler(struct iwl_priv *priv, s32 temp, bool force)
|
|
|
}
|
|
|
mutex_lock(&priv->mutex);
|
|
|
if (old_state == IWL_TI_CT_KILL)
|
|
|
- clear_bit(STATUS_CT_KILL, &priv->shrd->status);
|
|
|
+ clear_bit(STATUS_CT_KILL, &priv->status);
|
|
|
if (tt->state != IWL_TI_CT_KILL &&
|
|
|
iwl_power_update_mode(priv, true)) {
|
|
|
/* TT state not updated
|
|
@@ -463,7 +462,7 @@ static void iwl_advance_tt_handler(struct iwl_priv *priv, s32 temp, bool force)
|
|
|
IWL_ERR(priv, "Cannot update power mode, "
|
|
|
"TT state not updated\n");
|
|
|
if (old_state == IWL_TI_CT_KILL)
|
|
|
- set_bit(STATUS_CT_KILL, &priv->shrd->status);
|
|
|
+ set_bit(STATUS_CT_KILL, &priv->status);
|
|
|
tt->state = old_state;
|
|
|
} else {
|
|
|
IWL_DEBUG_TEMP(priv,
|
|
@@ -474,8 +473,7 @@ static void iwl_advance_tt_handler(struct iwl_priv *priv, s32 temp, bool force)
|
|
|
if (force) {
|
|
|
IWL_DEBUG_TEMP(priv,
|
|
|
"Enter IWL_TI_CT_KILL\n");
|
|
|
- set_bit(STATUS_CT_KILL,
|
|
|
- &priv->shrd->status);
|
|
|
+ set_bit(STATUS_CT_KILL, &priv->status);
|
|
|
iwl_perform_ct_kill_task(priv, true);
|
|
|
} else {
|
|
|
iwl_prepare_ct_kill_task(priv);
|