serial/imx: fix IMX UART macro usage to reflect correct processor

Platform dependant UART data refers to MX31 macro for MX35 machines.
For all other machines, macro usage matches machine type.

Though this compiles out to the same result, it looks much like
a typo, so fix it to use the right macros instead.

Signed-off-by: Oskar Schirmer <oskar@scara.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Sascha Hauer <s.hauer@pengutronix.de>
Oskar Schirmer 12 years ago
parent
commit
9954c57dfa
1 changed files with 1 additions and 1 deletions
  1. 1 1
      arch/arm/plat-mxc/devices/platform-imx-uart.c

+ 1 - 1
arch/arm/plat-mxc/devices/platform-imx-uart.c

@@ -87,7 +87,7 @@ const struct imx_imx_uart_1irq_data imx31_imx_uart_data[] __initconst = {
 #ifdef CONFIG_SOC_IMX35
 const struct imx_imx_uart_1irq_data imx35_imx_uart_data[] __initconst = {
 #define imx35_imx_uart_data_entry(_id, _hwid)				\
-	imx_imx_uart_1irq_data_entry(MX31, _id, _hwid, SZ_16K)
+	imx_imx_uart_1irq_data_entry(MX35, _id, _hwid, SZ_16K)
 	imx35_imx_uart_data_entry(0, 1),
 	imx35_imx_uart_data_entry(1, 2),
 	imx35_imx_uart_data_entry(2, 3),