@@ -229,16 +229,15 @@ static void snd_ad1848_mce_down(struct snd_ad1848 *chip)
|
|
|
spin_unlock_irqrestore(&chip->reg_lock, flags);
|
|
|
return;
|
|
|
}
|
|
|
- /* calibration process */
|
|
|
|
|
|
- for (timeout = 500; timeout > 0 && (snd_ad1848_in(chip, AD1848_TEST_INIT) & AD1848_CALIB_IN_PROGRESS) == 0; timeout--);
|
|
|
- if ((snd_ad1848_in(chip, AD1848_TEST_INIT) & AD1848_CALIB_IN_PROGRESS) == 0) {
|
|
|
- snd_printd("mce_down - auto calibration time out (1)\n");
|
|
|
- spin_unlock_irqrestore(&chip->reg_lock, flags);
|
|
|
- return;
|
|
|
- }
|
|
|
+ /*
|
|
|
+ * Wait for (possible -- during init auto-calibration may not be set)
|
|
|
+ * calibration process to start. Needs upto 5 sample periods on AD1848
|
|
|
+ * which at the slowest possible rate of 5.5125 kHz means 907 us.
|
|
|
+ */
|
|
|
+ msleep(1);
|
|
|
#if 0
|
|
|
- printk("(2) timeout = %i, jiffies = %li\n", timeout, jiffies);
|
|
|
+ printk("(2) jiffies = %li\n", jiffies);
|
|
|
#endif
|
|
|
time = HZ / 4;
|
|
|
while (snd_ad1848_in(chip, AD1848_TEST_INIT) & AD1848_CALIB_IN_PROGRESS) {
|