@@ -54,7 +54,8 @@ extern u8 acpi_gbl_default_address_spaces[];
|
|
|
|
|
|
/* Local prototypes */
|
|
|
|
|
|
-static void acpi_ev_orphan_ec_reg_method(void);
|
|
|
+static void
|
|
|
+acpi_ev_orphan_ec_reg_method(struct acpi_namespace_node *ec_device_node);
|
|
|
|
|
|
static acpi_status
|
|
|
acpi_ev_reg_run(acpi_handle obj_handle,
|
|
@@ -612,7 +613,7 @@ acpi_ev_execute_reg_methods(struct acpi_namespace_node *node,
|
|
|
/* Special case for EC: handle "orphan" _REG methods with no region */
|
|
|
|
|
|
if (space_id == ACPI_ADR_SPACE_EC) {
|
|
|
- acpi_ev_orphan_ec_reg_method();
|
|
|
+ acpi_ev_orphan_ec_reg_method(node);
|
|
|
}
|
|
|
|
|
|
return_ACPI_STATUS(status);
|
|
@@ -681,7 +682,7 @@ acpi_ev_reg_run(acpi_handle obj_handle,
|
|
|
*
|
|
|
* FUNCTION: acpi_ev_orphan_ec_reg_method
|
|
|
*
|
|
|
- * PARAMETERS: None
|
|
|
+ * PARAMETERS: ec_device_node - Namespace node for an EC device
|
|
|
*
|
|
|
* RETURN: None
|
|
|
*
|
|
@@ -693,37 +694,27 @@ acpi_ev_reg_run(acpi_handle obj_handle,
|
|
|
* detected by providing a _REG method object underneath the
|
|
|
* Embedded Controller device."
|
|
|
*
|
|
|
- * To quickly access the EC device, we use the EC_ID that appears
|
|
|
- * within the ECDT. Otherwise, we would need to perform a time-
|
|
|
- * consuming namespace walk, executing _HID methods to find the
|
|
|
- * EC device.
|
|
|
+ * To quickly access the EC device, we use the ec_device_node used
|
|
|
+ * during EC handler installation. Otherwise, we would need to
|
|
|
+ * perform a time consuming namespace walk, executing _HID
|
|
|
+ * methods to find the EC device.
|
|
|
+ *
|
|
|
+ * MUTEX: Assumes the namespace is locked
|
|
|
*
|
|
|
******************************************************************************/
|
|
|
|
|
|
-static void acpi_ev_orphan_ec_reg_method(void)
|
|
|
+static void
|
|
|
+acpi_ev_orphan_ec_reg_method(struct acpi_namespace_node *ec_device_node)
|
|
|
{
|
|
|
- struct acpi_table_ecdt *table;
|
|
|
+ acpi_handle reg_method;
|
|
|
+ struct acpi_namespace_node *next_node;
|
|
|
acpi_status status;
|
|
|
struct acpi_object_list args;
|
|
|
union acpi_object objects[2];
|
|
|
- struct acpi_namespace_node *ec_device_node;
|
|
|
- struct acpi_namespace_node *reg_method;
|
|
|
- struct acpi_namespace_node *next_node;
|
|
|
|
|
|
ACPI_FUNCTION_TRACE(ev_orphan_ec_reg_method);
|
|
|
|
|
|
- /* Get the ECDT (if present in system) */
|
|
|
-
|
|
|
- status = acpi_get_table(ACPI_SIG_ECDT, 0,
|
|
|
- ACPI_CAST_INDIRECT_PTR(struct acpi_table_header,
|
|
|
- &table));
|
|
|
- if (ACPI_FAILURE(status)) {
|
|
|
- return_VOID;
|
|
|
- }
|
|
|
-
|
|
|
- /* We need a valid EC_ID string */
|
|
|
-
|
|
|
- if (!(*table->id)) {
|
|
|
+ if (!ec_device_node) {
|
|
|
return_VOID;
|
|
|
}
|
|
|
|
|
@@ -731,22 +722,11 @@ static void acpi_ev_orphan_ec_reg_method(void)
|
|
|
|
|
|
(void)acpi_ut_release_mutex(ACPI_MTX_NAMESPACE);
|
|
|
|
|
|
- /* Get a handle to the EC device referenced in the ECDT */
|
|
|
-
|
|
|
- status = acpi_get_handle(NULL,
|
|
|
- ACPI_CAST_PTR(char, table->id),
|
|
|
- ACPI_CAST_PTR(acpi_handle, &ec_device_node));
|
|
|
- if (ACPI_FAILURE(status)) {
|
|
|
- goto exit;
|
|
|
- }
|
|
|
-
|
|
|
/* Get a handle to a _REG method immediately under the EC device */
|
|
|
|
|
|
- status = acpi_get_handle(ec_device_node,
|
|
|
- METHOD_NAME__REG, ACPI_CAST_PTR(acpi_handle,
|
|
|
- ®_method));
|
|
|
+ status = acpi_get_handle(ec_device_node, METHOD_NAME__REG, ®_method);
|
|
|
if (ACPI_FAILURE(status)) {
|
|
|
- goto exit;
|
|
|
+ goto exit; /* There is no _REG method present */
|
|
|
}
|
|
|
|
|
|
/*
|
|
@@ -754,19 +734,20 @@ static void acpi_ev_orphan_ec_reg_method(void)
|
|
|
* this scope with the Embedded Controller space ID. Otherwise, it
|
|
|
* will already have been executed. Note, this allows for Regions
|
|
|
* with other space IDs to be present; but the code below will then
|
|
|
- * execute the _REG method with the EC space ID argument.
|
|
|
+ * execute the _REG method with the embedded_control space_ID argument.
|
|
|
*/
|
|
|
next_node = acpi_ns_get_next_node(ec_device_node, NULL);
|
|
|
while (next_node) {
|
|
|
if ((next_node->type == ACPI_TYPE_REGION) &&
|
|
|
(next_node->object) &&
|
|
|
(next_node->object->region.space_id == ACPI_ADR_SPACE_EC)) {
|
|
|
- goto exit; /* Do not execute _REG */
|
|
|
+ goto exit; /* Do not execute the _REG */
|
|
|
}
|
|
|
+
|
|
|
next_node = acpi_ns_get_next_node(ec_device_node, next_node);
|
|
|
}
|
|
|
|
|
|
- /* Evaluate the _REG(EC,Connect) method */
|
|
|
+ /* Evaluate the _REG(embedded_control,Connect) method */
|
|
|
|
|
|
args.count = 2;
|
|
|
args.pointer = objects;
|