소스 검색

[PATCH] Altix snsc: duplicate kobject fix

from: Greg Howard <ghoward@sgi.com>

Fix Altix system controller (snsc) device names to include the slot number
of the blade whose associated system controller is the target of the device
interface.  Including the slot number avoids a problem we're currently
having where slots within the same enclosure are attempting to create
multiple kobjects with identical names.

Signed-off-by: Greg Howard <ghoward@sgi.com>
Signed-off-by: Andrew Morton <akpm@osdl.org>
Signed-off-by: Linus Torvalds <torvalds@osdl.org>
akpm@osdl.org 19 년 전
부모
커밋
8c4335a87c
1개의 변경된 파일2개의 추가작업 그리고 1개의 파일을 삭제
  1. 2 1
      drivers/char/snsc.c

+ 2 - 1
drivers/char/snsc.c

@@ -390,7 +390,8 @@ scdrv_init(void)
 			format_module_id(devnamep, geo_module(geoid),
 					 MODULE_FORMAT_BRIEF);
 			devnamep = devname + strlen(devname);
-			sprintf(devnamep, "#%d", geo_slab(geoid));
+			sprintf(devnamep, "^%d#%d", geo_slot(geoid),
+				geo_slab(geoid));
 
 			/* allocate sysctl device data */
 			scd = kzalloc(sizeof (struct sysctl_data_s),