@@ -43,7 +43,7 @@
|
|
|
|
|
|
#define NBR_AVG_SAMPLES 20
|
|
|
|
|
|
-#define LOW_BAT_CHECK_INTERVAL (2 * HZ)
|
|
|
+#define LOW_BAT_CHECK_INTERVAL (HZ / 16) /* 62.5 ms */
|
|
|
|
|
|
#define VALID_CAPACITY_SEC (45 * 60) /* 45 minutes */
|
|
|
#define BATT_OK_MIN 2360 /* mV */
|
|
@@ -169,6 +169,7 @@ struct inst_curr_result_list {
|
|
|
* @recovery_cnt: Counter for recovery mode
|
|
|
* @high_curr_cnt: Counter for high current mode
|
|
|
* @init_cnt: Counter for init mode
|
|
|
+ * @low_bat_cnt Counter for number of consecutive low battery measures
|
|
|
* @nbr_cceoc_irq_cnt Counter for number of CCEOC irqs received since enabled
|
|
|
* @recovery_needed: Indicate if recovery is needed
|
|
|
* @high_curr_mode: Indicate if we're in high current mode
|
|
@@ -210,6 +211,7 @@ struct ab8500_fg {
|
|
|
int recovery_cnt;
|
|
|
int high_curr_cnt;
|
|
|
int init_cnt;
|
|
|
+ int low_bat_cnt;
|
|
|
int nbr_cceoc_irq_cnt;
|
|
|
bool recovery_needed;
|
|
|
bool high_curr_mode;
|
|
@@ -1879,25 +1881,29 @@ static void ab8500_fg_low_bat_work(struct work_struct *work)
|
|
|
|
|
|
/* Check if LOW_BAT still fulfilled */
|
|
|
if (vbat < di->bm->fg_params->lowbat_threshold) {
|
|
|
- di->flags.low_bat = true;
|
|
|
- dev_warn(di->dev, "Battery voltage still LOW\n");
|
|
|
-
|
|
|
- /*
|
|
|
- * We need to re-schedule this check to be able to detect
|
|
|
- * if the voltage increases again during charging
|
|
|
- */
|
|
|
- queue_delayed_work(di->fg_wq, &di->fg_low_bat_work,
|
|
|
- round_jiffies(LOW_BAT_CHECK_INTERVAL));
|
|
|
+ /* Is it time to shut down? */
|
|
|
+ if (di->low_bat_cnt < 1) {
|
|
|
+ di->flags.low_bat = true;
|
|
|
+ dev_warn(di->dev, "Shut down pending...\n");
|
|
|
+ } else {
|
|
|
+ /*
|
|
|
+ * Else we need to re-schedule this check to be able to detect
|
|
|
+ * if the voltage increases again during charging or
|
|
|
+ * due to decreasing load.
|
|
|
+ */
|
|
|
+ di->low_bat_cnt--;
|
|
|
+ dev_warn(di->dev, "Battery voltage still LOW\n");
|
|
|
+ queue_delayed_work(di->fg_wq, &di->fg_low_bat_work,
|
|
|
+ round_jiffies(LOW_BAT_CHECK_INTERVAL));
|
|
|
+ }
|
|
|
} else {
|
|
|
- di->flags.low_bat = false;
|
|
|
+ di->flags.low_bat_delay = false;
|
|
|
+ di->low_bat_cnt = 10;
|
|
|
dev_warn(di->dev, "Battery voltage OK again\n");
|
|
|
}
|
|
|
|
|
|
/* This is needed to dispatch LOW_BAT */
|
|
|
ab8500_fg_check_capacity_limits(di, false);
|
|
|
-
|
|
|
- /* Set this flag to check if LOW_BAT IRQ still occurs */
|
|
|
- di->flags.low_bat_delay = false;
|
|
|
}
|
|
|
|
|
|
/**
|
|
@@ -2056,6 +2062,7 @@ static irqreturn_t ab8500_fg_lowbatf_handler(int irq, void *_di)
|
|
|
{
|
|
|
struct ab8500_fg *di = _di;
|
|
|
|
|
|
+ /* Initiate handling in ab8500_fg_low_bat_work() if not already initiated. */
|
|
|
if (!di->flags.low_bat_delay) {
|
|
|
dev_warn(di->dev, "Battery voltage is below LOW threshold\n");
|
|
|
di->flags.low_bat_delay = true;
|
|
@@ -2698,6 +2705,12 @@ static int ab8500_fg_probe(struct platform_device *pdev)
|
|
|
INIT_DEFERRABLE_WORK(&di->fg_check_hw_failure_work,
|
|
|
ab8500_fg_check_hw_failure_work);
|
|
|
|
|
|
+ /* Reset battery low voltage flag */
|
|
|
+ di->flags.low_bat = false;
|
|
|
+
|
|
|
+ /* Initialize low battery counter */
|
|
|
+ di->low_bat_cnt = 10;
|
|
|
+
|
|
|
/* Initialize OVV, and other registers */
|
|
|
ret = ab8500_fg_init_hw_registers(di);
|
|
|
if (ret) {
|