فهرست منبع

mac80211: Fix invalid length passed to IE parser for PLINK CONFIRM frames

The length of the fixed portion of plink confirm frames is 4 bytes longer than
the other plink_action frames.  This path corrects an error in the length
adjustment done for these type of frames.

Signed-off-by: Javier Cardona <javier@cozybit.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
David Woo 16 سال پیش
والد
کامیت
70bdb6b275
1فایلهای تغییر یافته به همراه1 افزوده شده و 1 حذف شده
  1. 1 1
      net/mac80211/mesh_plink.c

+ 1 - 1
net/mac80211/mesh_plink.c

@@ -409,7 +409,7 @@ void mesh_rx_plink_frame(struct ieee80211_sub_if_data *sdata, struct ieee80211_m
 	baselen = (u8 *) mgmt->u.action.u.plink_action.variable - (u8 *) mgmt;
 	if (mgmt->u.action.u.plink_action.action_code == PLINK_CONFIRM) {
 		baseaddr += 4;
-		baselen -= 4;
+		baselen += 4;
 	}
 	ieee802_11_parse_elems(baseaddr, len - baselen, &elems);
 	if (!elems.peer_link) {