Преглед на файлове

thermal: Fix polling frequency for systems without passive cooling

The polling interval (in deciseconds) was accidently interpreted as
being in milliseconds in one codepath, resulting in excessively frequent
polling. Ensure that the conversion is performed.

Signed-off-by: Matthew Garrett <mjg@redhat.com>
Acked-by: Zhang Rui <rui.zhang@intel.com>
Signed-off-by: Len Brown <len.brown@intel.com>
Matthew Garrett преди 16 години
родител
ревизия
67405439bc
променени са 1 файла, в които са добавени 1 реда и са изтрити 1 реда
  1. 1 1
      drivers/acpi/thermal.c

+ 1 - 1
drivers/acpi/thermal.c

@@ -909,7 +909,7 @@ static int acpi_thermal_register_thermal_zone(struct acpi_thermal *tz)
 			thermal_zone_device_register("acpitz", trips, tz,
 						     &acpi_thermal_zone_ops,
 						     0, 0, 0,
-						     tz->polling_frequency);
+						     tz->polling_frequency*100);
 	if (IS_ERR(tz->thermal_zone))
 		return -ENODEV;