be2net: Fix VLAN promiscous mode for Lancer

To enable VLAN promiscous mode, the HW interface should be created
with VLAN promiscous capability in Lancer. Add this capability during
creation of the HW interface.

Signed-off-by: Padmanabh Ratnakar <padmanabh.ratnakar@emulex.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Padmanabh Ratnakar 13 years ago
parent
commit
5d5adb93d0
1 changed files with 2 additions and 1 deletions
  1. 2 1
      drivers/net/ethernet/emulex/benet/be_main.c

+ 2 - 1
drivers/net/ethernet/emulex/benet/be_main.c

@@ -2600,7 +2600,8 @@ static int be_setup(struct be_adapter *adapter)
 	en_flags = BE_IF_FLAGS_UNTAGGED | BE_IF_FLAGS_BROADCAST |
 			BE_IF_FLAGS_MULTICAST | BE_IF_FLAGS_PASS_L3L4_ERRORS;
 	cap_flags = en_flags | BE_IF_FLAGS_MCAST_PROMISCUOUS |
-			BE_IF_FLAGS_PROMISCUOUS;
+			BE_IF_FLAGS_VLAN_PROMISCUOUS | BE_IF_FLAGS_PROMISCUOUS;
+
 	if (adapter->function_caps & BE_FUNCTION_CAPS_RSS) {
 		cap_flags |= BE_IF_FLAGS_RSS;
 		en_flags |= BE_IF_FLAGS_RSS;