소스 검색

ASoC: Debugged improper setting of PLL fields in WM8580 driver

Bug was caught while trying to use WM8580 as I2S master on SMDK.
Symptoms were lesser LRCLK read by CRO(41.02 instead of 44.1 KHz) Solved
by referring to WM8580A manual and setting mask value correctly and
making the code to not touch 'reserved' bits of PLL4 register.

Signed-off-by: Jassi <jassi.brar@samsung.com>
Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
jassi brar 15 년 전
부모
커밋
5c0d38c947
1개의 변경된 파일2개의 추가작업 그리고 2개의 파일을 삭제
  1. 2 2
      sound/soc/codecs/wm8580.c

+ 2 - 2
sound/soc/codecs/wm8580.c

@@ -458,12 +458,12 @@ static int wm8580_set_dai_pll(struct snd_soc_dai *codec_dai,
 		return 0;
 
 	snd_soc_write(codec, WM8580_PLLA1 + offset, pll_div.k & 0x1ff);
-	snd_soc_write(codec, WM8580_PLLA2 + offset, (pll_div.k >> 9) & 0xff);
+	snd_soc_write(codec, WM8580_PLLA2 + offset, (pll_div.k >> 9) & 0x1ff);
 	snd_soc_write(codec, WM8580_PLLA3 + offset,
 		     (pll_div.k >> 18 & 0xf) | (pll_div.n << 4));
 
 	reg = snd_soc_read(codec, WM8580_PLLA4 + offset);
-	reg &= ~0x3f;
+	reg &= ~0x1b;
 	reg |= pll_div.prescale | pll_div.postscale << 1 |
 		pll_div.freqmode << 3;