ARM: mach-shmobile: do not enable the PLLC2 clock on init

AP4EVB has to reparent PLLC2 to provide a precise HDMI clock, this is only
possible, if PLLC2 hasn't been enabled yet. Since no other driver currently
uses PLLC2 we can safely remove the CLK_ENABLE_ON_INIT flag. This fixes
the "Cannot set PLLC2 parent: -16, 1 users" error message, when trying to
use HDMI on AP4EVB.

Signed-off-by: Guennadi Liakhovetski <g.liakhovetski@gmx.de>
Signed-off-by: Paul Mundt <lethal@linux-sh.org>
Guennadi Liakhovetski 14 years ago
parent
commit
4e1774f3a5
1 changed files with 0 additions and 1 deletions
  1. 0 1
      arch/arm/mach-shmobile/clock-sh7372.c

+ 0 - 1
arch/arm/mach-shmobile/clock-sh7372.c

@@ -286,7 +286,6 @@ static struct clk_ops pllc2_clk_ops = {
 
 struct clk pllc2_clk = {
 	.ops		= &pllc2_clk_ops,
-	.flags		= CLK_ENABLE_ON_INIT,
 	.parent		= &extal1_div2_clk,
 	.freq_table	= pllc2_freq_table,