Переглянути джерело

iwl3945: Reset saved POWER_TABLE_CMD in "up"

Power-saving logic will not re-issue a POWER_TABLE_CMD if a new command
matches the prior one.  This can be bad if we re-start the device due to
e.g. uCode error; the new POWER_TABLE_CMD (required to invoke power-saving)
may match the prior POWER_TABLE_CMD issued before the uCode error.

Ensure the POWER_TABLE_CMD is sent to device when uCode is up.

Signed-off-by: Ben Cahill <ben.m.cahill@intel.com>
Signed-off-by: Reinette Chatre <reinette.chatre@intel.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
Ben Cahill 15 роки тому
батько
коміт
4d6ccbf57f
1 змінених файлів з 1 додано та 1 видалено
  1. 1 1
      drivers/net/wireless/iwlwifi/iwl3945-base.c

+ 1 - 1
drivers/net/wireless/iwlwifi/iwl3945-base.c

@@ -2493,7 +2493,7 @@ static void iwl3945_alive_start(struct iwl_priv *priv)
 	priv->active_rate = priv->rates_mask;
 	priv->active_rate_basic = priv->rates_mask & IWL_BASIC_RATES_MASK;
 
-	iwl_power_update_mode(priv, false);
+	iwl_power_update_mode(priv, true);
 
 	if (iwl_is_associated(priv)) {
 		struct iwl3945_rxon_cmd *active_rxon =