@@ -199,37 +199,42 @@ static void xen_get_wallclock(struct timespec *now)
|
|
|
|
|
|
static int xen_set_wallclock(const struct timespec *now)
|
|
|
{
|
|
|
- struct xen_platform_op op;
|
|
|
-
|
|
|
- /* do nothing for domU */
|
|
|
- if (!xen_initial_domain())
|
|
|
- return -1;
|
|
|
-
|
|
|
- op.cmd = XENPF_settime;
|
|
|
- op.u.settime.secs = now->tv_sec;
|
|
|
- op.u.settime.nsecs = now->tv_nsec;
|
|
|
- op.u.settime.system_time = xen_clocksource_read();
|
|
|
-
|
|
|
- return HYPERVISOR_dom0_op(&op);
|
|
|
+ return -1;
|
|
|
}
|
|
|
|
|
|
-static int xen_pvclock_gtod_notify(struct notifier_block *nb, unsigned long was_set,
|
|
|
- void *priv)
|
|
|
+static int xen_pvclock_gtod_notify(struct notifier_block *nb,
|
|
|
+ unsigned long was_set, void *priv)
|
|
|
{
|
|
|
- struct timespec now;
|
|
|
- struct xen_platform_op op;
|
|
|
+ /* Protected by the calling core code serialization */
|
|
|
+ static struct timespec next_sync;
|
|
|
|
|
|
- if (!was_set)
|
|
|
- return NOTIFY_OK;
|
|
|
+ struct xen_platform_op op;
|
|
|
+ struct timespec now;
|
|
|
|
|
|
now = __current_kernel_time();
|
|
|
|
|
|
+ /*
|
|
|
+ * We only take the expensive HV call when the clock was set
|
|
|
+ * or when the 11 minutes RTC synchronization time elapsed.
|
|
|
+ */
|
|
|
+ if (!was_set && timespec_compare(&now, &next_sync) < 0)
|
|
|
+ return NOTIFY_OK;
|
|
|
+
|
|
|
op.cmd = XENPF_settime;
|
|
|
op.u.settime.secs = now.tv_sec;
|
|
|
op.u.settime.nsecs = now.tv_nsec;
|
|
|
op.u.settime.system_time = xen_clocksource_read();
|
|
|
|
|
|
(void)HYPERVISOR_dom0_op(&op);
|
|
|
+
|
|
|
+ /*
|
|
|
+ * Move the next drift compensation time 11 minutes
|
|
|
+ * ahead. That's emulating the sync_cmos_clock() update for
|
|
|
+ * the hardware RTC.
|
|
|
+ */
|
|
|
+ next_sync = now;
|
|
|
+ next_sync.tv_sec += 11 * 60;
|
|
|
+
|
|
|
return NOTIFY_OK;
|
|
|
}
|
|
|
|
|
@@ -513,7 +518,9 @@ void __init xen_init_time_ops(void)
|
|
|
|
|
|
x86_platform.calibrate_tsc = xen_tsc_khz;
|
|
|
x86_platform.get_wallclock = xen_get_wallclock;
|
|
|
- x86_platform.set_wallclock = xen_set_wallclock;
|
|
|
+ /* Dom0 uses the native method to set the hardware RTC. */
|
|
|
+ if (!xen_initial_domain())
|
|
|
+ x86_platform.set_wallclock = xen_set_wallclock;
|
|
|
}
|
|
|
|
|
|
#ifdef CONFIG_XEN_PVHVM
|