e1000e: conditionally restart autoneg on 82577/8/9 when setting LPLU state

When setting the Low Power Link Up (LPLU, a.k.a. reverse auto-negotiation)
on 82577/8278/82579, do not restart auto-negotiation if reset of the Phy is
blocked by the Manageability Engine.

Signed-off-by: Bruce Allan <bruce.w.allan@intel.com>
Tested-by: Aaron Brown <aaron.f.brown@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
Bruce Allan 13 years ago