staging: omap-thermal: bandgap: fix setting of alert thresholds

There was an error in check for the valid temperature in
function temp_to_adc_conversion. The temperature value was
compared with higher limit for less than condition as well,
resulting in returning -EINVAL. Corrected the check condition
to properly check for lower and higher temperature limits.

Signed-off-by: Radhesh Fadnis <radhesh.fadnis@ti.com>
Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
Radhesh Fadnis 12 years ago
parent
commit
463bf503bd
1 changed files with 1 additions and 1 deletions
  1. 1 1
      drivers/staging/omap-thermal/omap-bandgap.c

+ 1 - 1
drivers/staging/omap-thermal/omap-bandgap.c

@@ -157,7 +157,7 @@ static int temp_to_adc_conversion(long temp, struct omap_bandgap *bg_ptr, int i,
 	high = ts_data->adc_end_val - ts_data->adc_start_val;
 	mid = (high + low) / 2;
 
-	if (temp < bg_ptr->conv_table[high] || temp > bg_ptr->conv_table[high])
+	if (temp < bg_ptr->conv_table[low] || temp > bg_ptr->conv_table[high])
 		return -EINVAL;
 
 	while (low < high) {